DRH_17 CRYDOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 8

Technical content

  • Ratings up to 18 & 20 Amps at 600 VAC
  • Fits standard 35 mm DIN Rail
  • Integrated over-temperature protection
  • Alarm output in case of over-temperature
  • Multicolor LED with input status and alarm indicator
  • AC or DC control
  • Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
  • C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
  • Built-in Overvoltage Protection
  • Fan controlled through thermistor and microprocessor to optimize fan operation PRODUCT SELECTION Control Voltage 18 A 90-280 VAC/VDC DRH3P60A18 4-32 VDC DRH3P60D18 20 A DRH3P60A20 DRH3P60D20 AVAILABLE OPTIONS Required for valid part number For options only and not required for valid part number Function 3P: Contactor Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On Operating Voltage 60: 48-600 VAC Series DRH 3P 60 R Control Voltage A: 90-280 VAC/VDC D: 4-32 VDC U Rated Load Current 18: 18 Amps (3 Controlled legs) 20: 20 Amps (2 Controlled legs) 18A OUTPUT SPECIFICATIONS (1)

Description

Operating Voltage (47-63Hz) [VRMS] Transient Overvoltage [Vpk] (2) Maximum Off-State Leakage Current @ Rated Voltage [mARMS] Minimum Off-State dV/dt @ Maximum Rated Voltage [V//uni03BCsec] Load Current, General Use UL508/IEC62314 @ 40°C [ARMS] (3) Minimum Load Current [ARMS] Maximum Surge Current [Apk] 1Cycle 60Hz Maximum Surge Current [Apk] 1Cycle 50Hz Maximum I²t for Fusing (8.33 msec) [A²sec]

20 A18 A

Load Current, Motor Starting UL508 FLA/IEC62314 @ 40°C [ARMS] (3) 7.6 7.6 0.15 0.15 750 750 716 716 2330 2330 Maximum I²t for Fusing (10 msec) [A²sec] 2560 2560 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 per channel 1.35 per channel Minimum Power Factor (with Maximum Load) 0.5 0.5 Motor Rating UL 508/ IEC60947-4-2 [HP/kW] :240 VAC 2/1.5 2/1.5 Motor Rating UL 508/ IEC60947-4-2 [HP/kW] :380 VAC 3/2.2 3/2.2 Motor Rating UL 508/ IEC60947-4-2 [HP/kW] :480 VAC 5/3.7 5/3.7 INPUT SPECIFICATIONS (1) Description DRH3P60Ax Control Voltage Range 90-280 VAC/VDC Minimum Turn-On Voltage 90 VAC/VDC Must Turn-Off Voltage 10 VAC Minimum Input Current (for on-state) 1 mA Maximum Input Current 3 mA Nominal Input Impedance [Ohms] 100k Maximum Turn-On Time [msec] 30 Maximum Turn-Off Time [msec] 40 DRH3P60Dx 4-32 VDC

4 VDC

1 VDC

1 Cycle

(4) Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DatasheetDIN Rail Mount

THERMAL DERATE INFORMATION (10) 20 30 40 50 60 70 Ambient Temperature (ºC) Load Current (Amps) DRH3P60x20 Single unit Multiple units (10) 20 30 40 50 60 70 Ambient Temperature (ºC) Load Current (Amps) DRH3P60x18 Single unit Multiple units POWER SUPPLY SPECIFICATIONS (1) Maximum Source Current [mA] Maximun Start Up Time [msec] 8-32 VDC

8 VDC

3 VDC

Maximun Shut Off Time [msec] 40 90-265 VAC/VDC

90 VAC/VDC

5 VAC/VDC

ALARM OUTPUT (1) Maximum Contact Switching Voltage [Volts] Rated Current Resistive [A] (5) Minimum Recommended Contact Load [mA] Static Contact Resistance (max. init.)[Ohms] Turn-On / Off Condition DRH3P60xxx

200 VDC, 120 VAC

0.5 0.2 See Status Chart GENERAL SPECIFICATIONS (1) Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) (6) 3750 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohm Maximum Capacitance, Input/Output 20 pF Ambient Operating Temperature Range (7) -10 to 70 °C Ambient Storage Temperature Range -40 to 70 °C Weight (typical) 2 Controlled Legs (7.4 oz [210 g]) / 3 Controlled Legs (8.5 oz [242 g]) Housing Material UL94 V-0 Housing Color Black and Light Gray LED Status Indicator (color) See Status Chart Short Circuit Current Rating (8) 100kA Control and Auxiliary Contact Terminal Screw Torque Range (in-lb/Nm) 12 / 1.36 Load Terminal Screw Torque Range (in-lb/Nm) 15 / 1.7 Input Terminal Wire Capacity 18-12 AWG (IEC 1-4 mm2) (stranded /solid) Output Terminal Wire Capacity 18-10 AWG (IEC 1-6 mm2) (stranded /solid) Humidity 85% non-condensing Protection Degree (9) IP20 Pollution Degree 2 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DatasheetDIN Rail Mount

+A3 13 +A1 -A4 14 -A2 L1 L2 L3 T1 T2 T3 XXXX IND. CONT. EQ. DRH3P60xxx CONTROL INPUT / > / > / > Power Supply 90-265 VAC/VDC (for A Control Voltage) 8-32 VDC (for D Control Voltage) Alarm Output (0.5 A/200 VDC, 120 VAC) Normally Open T1 T2 T3 General Use / AC-51 ApplicationT1 T2 T3 T1 T2 T3 M Motor Controller / AC-53a Application DRHP60x18 (3 controlled legs model) Main Circuit +A1 -A2 +A3 -A4 DRHP60x20 (2 controlled legs model) Main Circuit +A1 -A2 +A3 -A4 Alarm Output (DRHP60x18 & DRHP60x20) 48-600 VAC, 50-60Hz Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DatasheetDIN Rail Mount

SHORT CIRCUIT AND OVERLOAD PROTECTION FOR ALL DEVICES IEC standard 60947-4-1 make a distinction between two different types of protection, (called “coordination”), which are designated types “1” and "2". Any short-circuit that occurs is cleared safely by either type of coordination. The only difference between the 2 categories concerns the extent of the SSR damage caused by the short-circuit. Type "1" coordination requires that in the event of a short-circuit, the Solid State Contactor does not endanger personnel or installations, but permanent damage to the SSC is permissible. In this case the SSC may need to be replaced. For this type of co-ordination, the use of fusing or circuit breakers adequate to protect the system and wiring from short circuits, (but not specifically considering SSC protection), can be used. Type "2" coordination requires that under a short-circuit condition, the circuit is interrupted, the SSC does not endanger persons or installations, and in addition the SSR will be able to operate after the fault condition is repaired. Type of coordination 1 Protection by Thermal Magnetic Circuit Breaker or by Fuse Nominal Motor Current Class gG fuses (example from Littlefuse) Solid State Contactor 2 controlled legs Solid State Contactor 3 controlled legs 0.40-0.63 A CY14X51G16 DRH3P60x20 DRH3P60x18 0.63-1 A CY14X51G16 DRH3P60x20 DRH3P60x18 1-1.6 A CY14X51G25 DRH3P60x20 DRH3P60x18 1.6-2.5 A CY14X51G25 DRH3P60x20 DRH3P60x18 2.5-4 A CY14X51G25 DRH3P60x20 DRH3P60x18 4-6.3 A CY14X51G40 DRH3P60x20 DRH3P60x18 DRH3P60x18 (up to 7.6A)6.3-10 A CY14X51G40 DRH3P60x20 (up to 7.6A) GV2ME04 / GV2P04 GV2ME05 / GV2P05 GV2ME06 / GV2P06 GV2ME07 / GV2P07 GV2ME08 / GV2P08 GV2ME10 / GV2P10 GV2ME14 / GV2P14 Thermal Magnetic Circuit Breaker (Schneider Electric) Type of coordination 2 0.15-20 A CY14X51G25 DRH3P60x20 DRH3P60x18 (up to 18A) Nominal Current Class gG fuses (example from Littlefuse) Solid State Contactor 2 controlled legs Solid State Contactor 3 controlled legs Protection by Thermal Magnetic Circuit Breaker or by Fuse Protection by Fuse Nominal Current Semiconductor fuses with less than 2330 A2s Littlefuse Solid State Contactor 2 controlled legs Solid State Contactor 3 controlled legs 0.15-20 A LA50QS35-4 DRH3P60x20 DRH3P60x18 (up to 18A) 50 058 06.32 Z093908 Ferraz (Cylindric)SIBA1 (Cylindric) Protection by Fuse Nominal Motor Current Semiconductor fuses with less than 2330 A2s Littlefuse Solid State Contactor 2 controlled legs Solid State Contactor 3 controlled legs 0.15-7.6 A LA50QS40-4 DRH3P60x20 DRH3P60x1850 058 06.40 A093909 Ferraz (Cylindric)SIBA1 (Cylindric) For resistive loads: For motor loads: For resistive loads: For motor loads: Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DatasheetDIN Rail Mount (11) (11) (11) (11)

Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Top/Bottom view (Fig. 1) Fig. 1 TERMINAL SCREW TYPE INPUT STATUS XXXX IND. CONT. EQ. DRH3 1.23 [31.3] 2.29 [58.3] 2.58 [65.5] 1.68 [42.7] 3.41 [86.7] 1.78 [45.3] 3.76 [95.6] 3.51 [89] 2.91 [73.9] 0.23 [5.8] +A1 -A2 13+A3 14-A4 Blue LED Color Green Red1, 15 2, 14 4, 12 5, 11 6, 10 Initial Condition Stand by condition. LED is blinking Blue. Fan is activated at full speed for 2 seconds after power is applied to A3 A1 is On, Output is activated, temperature rises. LED is Green Fan is activated at 50% speed. If A1 is disabled, LED changes to blinking Blue Fan is at 75% speed LED changes to blinking Red, fan is at full speed Output is Off, Alarm Output is On, LED changes to solid Red If A1 is disabled while alarm output is active, LED alternates between Blue and Red LED is solid Red, temperature starts to fall Fan is activated at 50% speed, temperature is steady DescriptionStep Fan Speed LED Color Alarm Output Over Temperature Output Power Supply A3 Control Input A1 Alarm Pre-alarm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 3s 3s2s 50% 50%75% 75%100% 100%0%3s Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DatasheetDIN Rail Mount

Rev. 052616 GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) Relay will self trigger between 950-1200V, Not suitable for capacitive loads. (3) Mounted in the Vertical position. (4) Turn-on time for Instantaneous turn-on version is 4 msec. (5) Decrease Maximun Current 15mA/°C above 40°C ambient temperature. (6) For input to alarm output the dielectric strength is 1.5kV. (7) UL approval up to 40°C surrounding temperature. (8) 100kA, 480 VAC, when protected with CC class fuses rated 600VAC, 20 A or equivalent. (9) IP20 rating is not associated with the UL approval. (10) Minimum spacing to obtain max. current is 22mm between adjacent units. (11) Combination of these Protective Devices and Solid State Contactor have not been evaluated by UL. ID Marker ID Marker CNLB CNLN CNL2 Package of 10 plastic strip comprising 10 individual markers which can be placed for easy identification during the use of multiple units. E116949 AGENCY APPROVALS United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. China Compulsory Certification for AC Semiconductor Motor Controller-GB14048.6-2008 DRH series conforms to the harmonized EN standard EN/IEC 60947-4-2 Electromagnetic Compatibility: IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 Vibration Resistance: IEC 60068-2-6: Amplitude Range 10-55 Hz, Displacement 0.75mm Shock Resistance: IEC 60068-2-27: Peak Acceleration 15g, Duration 11msec. Certification in accordance with: Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DatasheetDIN Rail Mount s

DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • Disconnect all power before installing or working with this equipment.
  • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
  • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
  • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
  • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
  • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
  • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
  • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
  • Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
  • Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie 存在电击、 爆炸或电弧 闪烁危险
  • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
  • The product's side panels may be hot, allow the product to cool before touching.
  • Follow proper mounting instructions including torque values.
  • Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
  • Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
  • Respecter les consignes de montage, et notamment les couples de serrage.
  • Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
  • Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
  • Beachten Sie die Montageanweisungen,
  • Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
  • Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
  • Respetar las instrucciones de montaje, y en particular los pares de apretado.
  • No dejar que penetren líquidos o cuerpos extraños en el producto. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
  • I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
  • Seguire le istruzioni di montaggio corrette.
  • Non far entrare liquidi o oggetti estranei in questo apparecchio. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
  • 产品的一侧面板可能很热,在其冷却前请 不要触碰。
  • 遵照正确的安装说明,包括扭矩值。
  • 请勿让液体及其他异物进入本产品。 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DatasheetDIN Rail Mount

ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DatasheetDIN Rail Mount