DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
,QGXVWULDO 7HVW 120W - 480W Single Output DIN Rail Mount Power Supplies DRF Series (provisional datasheet) 1 www.uk.tdk-lambda.com/drf Specifications MODELS DRF-120-24-1 DRF-240-24-1 DRF-480-24-1 AC Input voltage range V AC 85-264 Input frequency Hz 47-63 Inrush cold (typ) A 20 40 Output voltage V 24 Output current A 5 10 20 Peak output current (1) A 7.5 15 30 Peak output power (1) W 180 360 720 Line regulation mV <96 Load regulation mV <240 Ripple and noise (2 & 3) mV <240 Over current protection (4) - >105% peak output current Over voltage protection (5) V 30-35.5 Hold up time (230V AC) ms 20 Efficiency (typ) (230VAC) % 91 94 Average efficiency (230VAC) % 88.6 92.4 92 Standby input power (230V AC) W <0.5 <0.5 <0.75 Parallel operation (6) - Possible Series operation (6) - Possible LED indicators - DC OK signal - green (Vout > 80% rated output voltage): Peak power mode - red DC OK relay (24V model only) - Relay contact 30V/1A Operating temperature °C -25°C to +70°C(60 to 70°C derate linearly to 75% load) Storage temperature °C -40°C to +85°C Operating humidity - 5-95% RH (non condensing) Cooling - Convection Withstand voltage - I/P to FG:1.5kVAC (20mA), I/P to O/P 3kVAC (20mA), O/P to FG: 500VAC (100mA) for 1 min Isolation resistance MΩ I/P to FG, IP to O/P and O/P to FG: >100MOhms (500VDC) at 25°C & 70%RH V ibration - Non-operating,10-55Hz(sweep for 1 min.):19.6 m/s2 constant, X,Y,Z axis 1 hour each Shock - <196m/s2 Safety agency approvals (7) - IEC/EN/UL60950-1, CE, UL508 listed, ATEX, IEC Ex, GL Emissions - EN55022 Class B, CISPR22-B W eight (typ) g 600 900 1300 Size (W x H x D) mm 36.5 x 123.4 x 1 15 49 x 123.4 x 1 15 82 x 123.4 x 1 15 Case material - Metal Warranty yrs 5 See Page 2 for Notes %URDGFDVW Features Benefits
- 150% Peak Power, 4 sec • Better Start-up of Capacitive & Inductive Loads
- Efficiency up to 94% • Cooler Applications - Improved Thermal Performance
- Ultra Compact Footprint • Saves Space on Rail and Cabinet Cost
- ErP Referenced Design • Better “Environmental Footprint”
- Remote On/Off • For Intelligent System Implementation
- Remote Programming • Wide Range of Applications
DRF Series (provisional datasheet)2 Model Selector Output Output Adjust Max Output Max Output Efficiency at Model V oltage Range (V) Current (A) Power (W) 1 15/230VAC (%) DRF120-24-1 24 24-28 5 120 89/91 DRF240-24-1 24 24-28 10 240 92.5/94 DRF480-24-1 24 24-28 20 480 92.5/94 Optional Models Suffix Description /HL Conformally Coated (A TEX, IEC EX, GL) Notes from page 1 1. Operating period at peak output current is 4 sec, max duty cycle<35% &< rated output power 2. At 115/230VAC, Ta = 25°C, nominal output voltage, rated output power 3. Ripple & noise is measured at 20MHz using 300mm twisted pair of load wires terminated with 0.1µF film cap & 47µF electrolytic cap 4. Constant current (CC) limit for >101% of peak output current. CC limit with auto recovery within 4 sec, unit will shutdown at >4sec 5. Output will shutdown, manual reset by mains cycle off/on or CNT on/off 6. Refer to instruction manual 7. Select /HL model for ATEX, IEC Ex and GL (Germanischer Lloyd) approvals (see optional models table) *Signal connectors are found on the topside of the unit. See product outline drawings for locations Signal Connector Pin Assignment PIN Function Detail 1 CB For parallel operation cut the link between pins 1 & 2 for droop mode current share
2 CB-COM
3 N/C
4 N/C
5 CNT+
Remote ON/OFF control, when CNT+ is pulled to TTL low the power supply turns ON, otherwise it turns OFF
6 CNT -
Programming voltage range 5 - 6V presets the output to 24 - 28V
8 COMM
DRF120 example* Terminal Explanation Connection 1 +V : +Output terminal 2 –V : –Output terminal 3 V .ADJ: Output voltage adjust trimmer The output voltage rises when a trimmer is turned clockwise 4 L: AC Input terminal. Live line (fuse in line) 5 N: AC Input terminal. Neutral line 6 –V : Protective Earth Connect to safety ground of apparatus or equipment
7 DC OK:
Green LED lights when output voltage is > 80% of rated output voltage
8 PEAK:
Red LED lights when unit is in peak power mode
9 DC OK: Relay contact
10 DC OK: Relay contact
DRF Series (provisional datasheet) 3 DRF120-24-1 Outline Drawing
DRF Series (provisional datasheet)4 DRF240-24-1 Outline Drawing
DRF480-24-1 Outline Drawing DRF Series (provisional datasheet) 5
www.emea.tdk-lambda.com TDK-Lambda France SAS ZAC des Delaches CS 41077 9 rue Thuillere
91978 Villebon Courtaboeuf
Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com Italy Sales Office Via dei Lavoratori 128/130
20092 Cinisello Balsamo (MI)
Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com Netherlands info@tdk-lambda.nl www.tdk-lambda.nl TDK-Lambda Germany GmbH Karl-Bold-Strasse 40
77855 Achern
Tel: +49 7841 666 0 Fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com Austria Sales Office Aredstrasse 22
2544 Leobersdorf
Tel: +43 2256 655 84 Fax: +43 2256 645 12 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com Scandinavia Sales Office Valdemarsgade 7
4100 Ringsted
Tel: +45 24 63 95 65 Fax: +45 69 80 44 99 info@de.tdk-lambda.com www.emea.tdk-lambda.com Switzerland Sales Office Bahnhofstrasse 50
8305 Dietlikon
Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 info@de.tdk-lambda.com www.de.tdk-lambda.com TDK-Lambda UK Ltd. Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com TDK-Lambda Ltd. Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 info@tdk-lambda.co.il www.tdk-lambda.co.il Russia Technical Support: St Petersburg Tel: +7 (812) 6580463 Sales: Moscow info@tdk-lambda.ru www.tdk-lambda.ru Local Distribution DRF Dec13 v4 DRF Series (provisional datasheet)6 RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach / Germany Tel. +49.69.984047-0 Fax +49.69.984047-77 info@rsg-electronic.de www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice.