Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Highlights & Features – Protection Class II, Double Isolation (No Earth connection is required) – Universal AC input voltage and full power up to 55°C – Power will not de-rate for the entire input voltage range – Efficiency > 88.0% @ 115Vac & 230Vac – NEC Class 2 / Limited Power Source (LPS) certified – Overvoltage / Overcurrent / Over Temperature Protections Safety Standards CB Certified for worldwide use Model Number: DRC-24V60W1AZ Unit Weight: 0.22 kg Dimensions (L x W x D): 91 x 71 x 55.6 mm General Description The DRC-24V60W1AZ is part of the Chrome DIN Rail Power Supply series, which is designed for use in compact cabinets for home automations and the food and beverage industry. Delta’s Chrome DIN Rail Power Supply series offers double isolated input. Thi s means that no Earth connection is required thus resul ting in low leakage current. This product provides a universal input voltage range of 90-264Vac, and a wide temperature range of -2 5°C to 7 1°C. The Chrome series is certified to safety standard according to IEC/EN/UL 60950-1 Information Technology Equipment (ITE) and UL 508 Industrial Control Equipment (ICE). The series is also fully compliant with RoHS Directive 2011/65/EU for environmental protection. NEC Class 2 and Limited Power Source (LPS) approvals are available for this product. Model Information Chrome DIN Rail Power Supply Model Number Input Voltage Range Output Voltage Output Current DRC-24V60W1AZ 90-264Vac (125-375Vdc) 24Vdc 2.50A Model Numbering DR C – 24V 60W 1 A Z DIN Rail Isolation Class II Power Supply Output Voltage Output Power Single Phase Chrome Series Plastic Case
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 90-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Nominal DC Input Voltage* 125-375Vdc Input Current < 1.50A @ 115Vac, < 1.00A @ 230Vac Efficiency at 100% Load > 88.0% @ 115Vac & 230Vac Max Inrush Current (Cold Start) < 30A @ 115Vac, < 60A @ 230Vac Power Factor Conform to EN 61000-3-2 Leakage Current < 0.25mA @ 240Vac *Fulfills the test conditions for this range. Output Ratings / Characteristics Nominal Output Voltage 24Vdc Output Voltage Tolerance ± 2% (initial set point tolerance from factory) Output Voltage Adjustment Range 24-28Vdc Output Current 2.50A Output Power 60W Line Regulation < 1% typ. (@ 90-264Vac, 100% load) Load Regulation < 2% typ. (@ 90-264Vac, 100% load) PARD (20MHz) 150mVpp Rise Time < 100ms @ nominal input (100% load) Start-up Time < 3,000ms @ nominal input (100% load) Hold-up Time > 16ms @ 115Vac, > 30ms @ 230Vac (100% load) Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 10-100% load Start-up with Capacitive Loads 3,000µF Max Mechanical Case Cover Plastic Dimensions (L x W x D) 91 x 71 x 55.6 mm Unit Weight 0.24 kg Indicator Green LED (DC OK) Cooling System Convection Terminal Input 2 Pins (Rated 300V/25A) Output 4 Pins (Rated 300V/25A) Wire Input / Output AWG 22-12 Mounting Rail Standard TS35 DIN Rail in accordance with EN 60715 Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 25dBA
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Environment Surrounding Air Temperature Operating -25°C to +71°C Storage -25°C to +85°C Power De-rating > 55°C de-rate power by 2.5% / °C Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 2,000 Meters Shock Test (Operating) IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms, 3 shocks for each 3 directions, 9 times in total Vibration (Operating) IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/S² (2G peak); 10 min per cycle, 60 min for all X, Y, Z directions Pollution Degree 2 Protections Overvoltage < 34.8V, SELV Output, Latch-off Mode Overload / Overcurrent > 110% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Over Temperature < 75°C Surrounding Air Temperature @ 100% load, Latch-off Mode Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Degree of Protection IP20 Protection Against Shock Class II (No PE* connection is required) *PE: Primary Earth Reliability Data MTBF > 500,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% load, Ta: 35°C Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40°C)
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Safety Standards / Directives Electrical Safety TUV to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, Limited Power Source (LPS) Industrial Control Equipment UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 Class 2 Power Supply UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.0KVac EMC EMC / Emissions CISPR 22, EN 55022, FCC Title 47: Class A* Immunity to EN 55024 Electrostatic Discharge IEC 61000-4-2 Level 3 Criteria A1) Air Discharge: 8kV Contact Discharge: 4kV Radiated Field IEC 61000-4-3 Level 2 Criteria A1) 80MHz-1GHz, 3V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 2kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Conducted IEC 61000-4-6 Level 2 Criteria A1) 150kHz-80MHz, 3Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 1A/Meter Voltage Dips IEC 61000-4-11 > 95% dip; 0.5 cycle (10ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Voltage Fluctuation and Flicker IEC/EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) *Warning: This is a Class A product. In a residential, commercial or light industrial environment it may cause radio interference. This product is not intended to be installed in a residential environment; in a commercial and light industrial environment with connection to the public mains supply, the user may be required to take adequate measures to reduce interference.
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Block Diagram Device Description 1) Input terminal block connector 2) Output terminal block connector 3) DC voltage adjustment potentiometer 4) DC OK control LED (Green) 5) Universal mounting system
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Dimensions L x W x D: 91 x 71 x 55.6 mm Engineering Data De-rating Note 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature > 55°C, the device may run into Over Temperature Protection. When activated, the output voltage will go into latch- off mode and recoverable by AC power recycle. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 25mm with adjacent units while the device is in operation. 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. If the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. Fig. 1 De-rating for Vertical Mounting Orientation > 55°C de-rate power by 2.5% / °C
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Output De-rating VS. Input Voltage Assembly & Installation The power supply unit (PSU) can be mounted on 35mm DIN rails in accordance with EN 60715. The device should be installed with input terminal block at the bottom. Each device is delivered ready to install. Mounting No output power de -rating across the entire input voltage range Dismounting Fig. 2.1 Mounting Snap on the DIN rail as shown in Fig. 2.1: 1. Tilt the unit upwards and insert it onto the DIN rail. 2. Push downwards until stopped. 3. Press against the bottom front side for locking. 4. Shake the unit slightly to ensure that it is secured. Fig. 2.2 Dismounting To uninstall, pull or slide down the latch with screw driver as shown in Fig. 2.2. Then slide the power supply unit (PSU) in the opposite direction, release the latch and pull out the power supply unit (PSU) from the rail.
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Safety Instructions Functions ■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its set value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 90% of its set value, after the input voltage is removed. – ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit. If mains are not turned OFF, there is risk of explosion / severe damage. – To guarantee sufficient convection cooling, keep a distance of 50mm above and below the device as well as a lateral distance of 25mm to other units. – Note that the enclosure of the device can become very hot depending on the surrounding air temperature and load of the power supply. Risk of burns! – DO NOT insert any objects into the unit. – Hazardous voltages may be present for up to 5 minutes after the input mains voltage is disconnected. Do not touch the unit during this time. – The power supplies unit should be installed in minimum IP54 rated enclosure. – The power supplies are built in units and must be instal led in a cabinet or room (condensation free environment and indoor location) that is relatively free of conductive contaminants.
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 10 to 100% of its rated current. Overvoltage Protection The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. Overload & Overcurrent Protections The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated when output current exceeds 110% of IO (Max load). In such occurrence, once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into latch-off mode until the component temperature cools down and the AC power is recycled. Short Circuit Protection The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed.
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Operating Mode Redundancy Operation In order to ensure proper redundancy operation for the power supply unit (PSU), ensure that the output voltage difference bet ween the two units is kept at 0.45~0.50V for 24V supplies. Follow simple steps given below to verify: Step 1. Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then V O of PSU 1 must be higher than PSU 2. In order to set the output voltage, connect the power supply to 50% load and set the PSU 1 and PSU 2 output voltage. Step 2. Connect the right DRR module, 20A as per the system requirement to the power supply units PSU 1 and PSU 2 at V in 1 & V in 2 respectively. Step 3. Connect the system load from V out. Please note that output voltage V out from DRR module will be = V O (output voltage of power supply) – Vdrop* (in DRR module). Parallel Operation + 2.5A + 2.5A = 7.5A) or current sharing, and thus increasing the power supply and system reliability. Though the DRC -24V60W1AZ is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple steps as below (Refer to Fig. 3 for the Connection Diagram). Fig. 3 Redundancy / Parallel Operation Connection Diagram Step 1. Set output load condition for both supplies at 50% and measure the output voltages. Step 2. Adjust output voltages to the same level or within ±25mV difference. Step 3. Connect PSU 1 and PSU 2 with the DRR -20A module and measure at Vin 1 & Vin 2 to verify the voltage difference. Ensure the voltages are within ±25mV. Step 4. Output voltage from DRR module V out will be = V O (output voltage of power supply) – Vdrop* (in DRR module). *Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature.
Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1AZ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (July 2014, Rev. 00) Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for “Restriction of the use of cer tain hazardous substances in electrical and electronic equipment”. This product conforms to this standard.