Features
- 10mm Single Channel DIN Rail Mount SSR Assembly
- AC Ratings up to 380 VAC and 10 Amps
- 3-15 VDC, 15-32VDC, 18-36 VAC and 90-140 VAC Control
- Cage style screw terminals for easy connection
- Fits standard 35mm DIN rail
- Includes LED Status Indicator (DC Control Only) Description 3A 5A 6A 10A(5) 10A(5) Operating Voltage [VDC] 1 - 200 1 - 60 1 - 100 1 - 60 1 - 100 Maximum Off-Sate Leakage Current @ Rated Voltage [µAdc] 100 100 100 100 (2) 100 Maximum Load Current [A] (3) 3 5 6 10 10 Minimum Load Current [A] 0 0 0 0 0 Maximum Surge Current (10msec) [Apk] 30 60 100 100 100 Maximum On-State Voltage Drop Control Voltage 3A 5A 6A 10A(5) 10A(5) 3 - 10 VDC DRA1-CMX200D3 DRA1-CMX60D5 DRA1-CMX100D6 DRA1-CMX60D10 DRA1-CMX100D10 20 - 28 VDC DRA1-CMXE200D3 DRA1-CMXE60D5 DRA1-CMXE100D6 DRA1-CMXE60D10 DRA1-CMXE100D10 DRA1 SERIES | CMX DC OUTPUT DIN RAIL MOUNT PRODUCT SELECTION
sensata.comCopyright © 2022 Sensata Technologies, Inc. Description DRA1-CMX DRA1-CMXE Control Voltage Range 3.0 - 10.0 VDC 20.0 - 28.0 VDC Must Turn-On Voltage 3.0 VDC 3.0 VDC Must Turn-Off Voltage 1.0 VDC 1.0 VDC Typical Input Current 15 mAdc @ 5 Vdc 12 mAdc @ 20 Vdc Nominal Input Impedance 300 Ohm 240 Ohm Maximum Turn-On Time [msec] (5) 1 1 Maximum Turn-Off Time [µsec] 300 300 Description Parameters Dielectric Strength (4) 2500 Vrms Maximum Insulation Resistance (@ 500 VDC) (4) 109 Ohm Maximum Capacitance, Input/Output 15 pF Ambient Operating Temperature Range -20 to 80°C Ambient Storage Temperature Range -20 to 125°C Weight (Typical) 0.063 oz (28.6 g) Encapsulation Thermally Conductive Epoxy Input (1) General (1) WIRING DIAGRAMS (A) (A) Wiring diagram is identical for each individual section whether it is a single or four channel assembly. (B) Load can be placed on either side of “Power” (C) DC inductive loads must be diode suppressed to prevent damage to SSR. For additional information or specific questions, contact Sensata Technical Support.
sensata.comCopyright © 2022 Sensata Technologies, Inc. MECHANICAL SPECIFICATIONS Tolerances: ±0.02 in / 0.5 mm All dimensions are in inches [millimeters] GENERAL NOTES THERMAL DERATE INFORMATION (1) All parameters at 25 °C unless otherwise specified. (2) At 55 Vdc. (3) See Derating Chart on page 4. (4) Dielectric and insulation resistance is measured between input and output (5) Steady state load Current exceeding 10 amps will damage socket. For additional information or specific questions, contact Sensata Technical Support. AGENCY APPROVALS & CERTIFICATIONS
- Designed in accordance with the requirements of IEC 62314
- UL: E116950 (3, 6, and 10 CMX Relays Only) 2.30 [58.5]
+1 (877) 502 5500 – Option 2 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Rev: 09/21/22 ECN 517202 FDE-07-01 Rev. B sensata.com CONTACT USCopyright © 2022 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.