DR67 SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 10

Technical content

Features

  • 3-Phase AC Output DIN Rail Mount SSRs
  • Output ratings up to 30 Amps at 600 VAC
  • 2 & 3 controlled Legs option
  • Over Temperature protection w/alarm (optional)
  • Built-in overvoltage protection
  • IP20 touch-safe housing
  • AC or DC control
  • cULus listed and VDE approved The DR67 is a compact 3-phase solid state relay in a DIN rail 67.5mm wide package with output ratings up to 30 Amps per channel @ 40°C. Its built-in overvoltage protection and the optional overtemperature protection make it suitable for demanding heating, motion and lighting applications. It’s easy to install and its large cage clamp terminals allow connecting wires up to 2 AWG size on the output terminals without the use of any additional accessories, therefore reducing installation cost and time. UL listed and VDE certified, the DR67 is a powerful and versatile solid state relay with superior performance when compared to previous generations and competitor products. PRODUCT SELECTION Control Voltage 25A 30A 4-32 VDC DR6760D25P DR6760D30P 90-280 VAC/VDC DR6760A25P DR6760A30P

Applications

  • Plastic injection molding equipment
  • Packaging equipment
  • Industrial ovens
  • Lighting control
  • Professional cooking equipment
  • Pump control
  • Conveyor drives
  • HVAC&R

www.sensata.comCopyright © 2019 Sensata Technologies, Inc. SPECIFICATIONS Output (2) Description 25A 30A Operating Voltage (47-440Hz) [VRMS] 48-600 48-600 Transient Overvoltage [Vpk] (3) 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mARMS] 1 1 Minimum Off-State dV/dt @ Maximum Rated Voltage [V/ μsec] 500 500 Load Current, General Use UL508/LC A IEC62314 @ 40°C [ARMS] 25 30 Load Current, Motor Starting UL508 FLA/LC B IEC62314 @ 40°C [ARMS] 12/6.8 12/6.8 Minimum Load Current [mARMS] 100 100 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 716/750 716/750 Maximum On-State Voltage Drop @ Rated Current [VRMS] 1.15 1.20 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 2563/2343 2563/2343 Minimum Power Factor (at Maximum Load) 0.5 0.5 ORDERING OPTIONS Example : DR6760A25RPTA Description of part number example Operating Voltage Control Voltage Family Rated Load Current Switching Type Overvoltage Protection D = 4-32 VDC (4-28 VDC for TA option) A = 90-280 VAC/VDC DR67 60 x xx x 25 = 25A, 3-legs 30 = 30A, 2-legs Blank = Zero voltage turn on R = Instantaneous turn on P = With internal overvoltage protection 48-600 VAC Over Temperature Protection(1) Blank = No Over Temperature protection TA = With Over Temperature Protection and Alarm Output P xx Required for valid part number For options only and not required for valid part number

www.sensata.comCopyright © 2019 Sensata Technologies, Inc. General (2) Description Parameters Dielectric Strength, Input to Output (50/60Hz) 4k VRMS Dielectric Strength, Input/Output to Case (50/60Hz) 4k VRMS Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 25 pF Ambient Operating Temperature Range -40 to 80 °C Ambient Storage Temperature Range -40 to 100 °C Short Circuit Current Rating (6) 100 kA Weight (typical) 31 oz (880 g) Housing Material UL94 V-0 Heat Sink Material Aluminum DIN Rail Clip Material Zinc Plated Steel Hardware Finish Nickel Plating Input Terminal Screw Torque Range (lb-in/Nm) 5/0.5 Load Terminal Screw Torque Range (lb-in/Nm) 18-20/2.0-2.2 Humidity per IEC 60068-2-78 (7) 93% LED Input Status Indicator See status chart Overvoltage Category III Impulse Withstand Voltage According to IEC 60664-1 6 kV Input (1) Alarm (2) Description DR6760Dxxx DR6760Axxx wo-TA Option w-TA Option wo-TA Option w-TA Option Control Voltage Range 4-32 VDC (4) 4-28 VDC(4) 90-280 VAC/VDC Maximum Reverse Voltage -32 VDC - Minimum Turn-On Voltage 4 VDC 90 VAC/VDC Must Turn-Off Voltage 1 VDC 5 VAC/VDC Minimum Input Current (for on-state) 25 mA 20 mA 1 mA 1 mA Maximum Input Current 40 mA 50 mA 4 mA 8 mA Nominal Input Impedance Current Limited Switching mode Maximum Turn-On Time [msec] 1/2 Cycle (5) 10 Maximum Turn-Off Time [msec] 1/2 Cycle 20 Description DR6760Dxxx DR6760Axxx Output type Solid State Solid State Maximum Output Voltage 60 VDC 400 VDC / 265 VAC Maximum Alarm Output Current [mA] 60 60

www.sensata.comCopyright © 2019 Sensata Technologies, Inc. EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS / > / > / > Short circuit and overload current protection T1 T2 T3 T1 T2 T3 T1 T2 T3 M DR6760X30 MAIN CIRCUIT DR6760X25 MAIN CIRCUIT L1 L2 L3 +A1 T1 T2 T3 -A2 L1 L2 L3 +A1 T1 T2 T3 -A2 ( 2 CONTROLLED LEGS ) ( 3 CONTROLLED LEGS ) CONTROL INPUT DR6760X25 DR6760X30 48-600 VAC, 47-440 Hz INPUT CTRL 4-32VDC L1 L2 L3 48-600VAC T1 T2 T3 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 INPUT Motor Controller Application General Use Application

www.sensata.comCopyright © 2019 Sensata Technologies, Inc. DR6760X25TA DR6760X30TA CONTROL INPUT / > / > / > Short circuit and overload current protection T1 T2 T3 T1 T2 T3 T1 T2 T3 M L1 L2 L3 +A1 T1 T2 T3 -A2 +A1 -A2 L1 L2 L3 T1 T2 T3 ALARM OUTPUT 48-600 VAC, 47-440 Hz A1 A2 A3 A4 INPUT CTRL 4-32VDC L1 L2 L3 48-600VAC T1 T2 T3 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 INPUT Motor Controller Application DR6760X30TA (2 CONTROLLED LEGS ) ALARM OUTPUT ALARM OUTPUTMAIN CIRCUIT MAIN CIRCUIT DR6760X25TA (3 CONTROLLED LEGS ) General Use Application

www.sensata.comCopyright © 2019 Sensata Technologies, Inc. MECHANICAL SPECIFICATIONS 4.04 102.6 1.96 49.7 Tolerances: ±0.02 in / 0.5 mm All dimensions are in inches [mm] INPUT CTRL 4-32VDC L1 L2 L3 48-600VAC T1 T2 T3 2/T1 4/T2 6/T3 1/L1 3/L2 5/L3 INPUT 5.82 147.8 4.39 111.5 3.61 91.8 2.93 74.5 .87 22.2 2.66 67.5 3X Ø .17 4.4 MOUNTING HOLE1.11 28.2 5.12 130.11.45 36.8 2.31 58.6

www.sensata.comCopyright © 2019 Sensata Technologies, Inc. SURGE CURRENT INFORMATION(8) 25A & 30A THERMAL DERATE INFORMATION STATUS CHART Conditions Description 1,11 Initial Condition. 2, 4 Control Input is On, Output is activated, temperature rises, Green LED is On. 3, 7 Control Input is Off, Output is Off. 5 LED changes to solid Orange color. 6, 9 Output is Off due to overtemperature, Alarm is latched On, LED changes to solid red. While Control Input is Off: Output, Alarm and LED remains Off. (Control Input Min. 100ms Off to reset values)

8 Control Input is On, Output is on and

temperature rises. 6, 10 Alarm will reset until Control Input is Off. LED Color Green Red Yellow * Max. 60 ms OFF when applying PWM on Control Input. Output On Alarm Pre-Alarm (only for models with overtemperature protection) TA SUFFIX MODELS

www.sensata.comCopyright © 2019 Sensata Technologies, Inc.

  • Locate rail and align with non moveable end of DR67 DIN clip.
  • Using reasonable force, push DR67 in the direction of the arrow (as shown in fig.1).
  • For removal pull release tag by moving blade of screwdriver in direction of arrow and pull it away from DIN rail. Mounting on Panel
  • Locate the panel section on which the DR67 SSR will be mounted on (as shown in fig.2)
  • DIN clip includes tabs for this type of mounting. Tab holes have a diameter of 4.5 mm. You will need three screws (not included) no larger than that to mount the SSR onto panel.
  • Align SSR tabs with panel surface and screw both top and bottom sides. Recommended torque is 12 lb-in (1.36 Nm). Wiring Instructions
  • Recommended wire sizes as shown in TABLE 1
  • Maximum terminal screw torque input terminal 5 lb-in (0.5 Nm) (screw terminal only)
  • Maximum terminal screw torque load terminal 18-20 lb-in (2.0-2.2 Nm)
  • Strip lenght for input terminals: Per manufacturer specifications
  • Strip lenght for load terminals: 10mm min.
  • Use only copper conductors rated for 75°C
  • If multiple units are installed be sure to follow derating curves. WARNING!!
  • Removing product from 35mm Rail incorrectly by not using the appropriate tool, would damage the latching system. fig.2 SSR mounted on panel fig.1 SSR mounted on DIN rail Pull to remove from DIN rail Push to install on DIN rail

Table 1. Wire Size & Pull Out Strength 32 UNC standard not provided with SSR. avoid the need of a further PE connection.

www.sensata.comCopyright © 2019 Sensata Technologies, Inc. AGENCY APPROVALS & CERTIFICATIONS Approvals (Tested and Certified According To) E116949 40047491 UL 508 and C22.2 No. 14 EN 62314 CONFORMANCES ENVIRONMENTAL Vibration Resistance IEC 60068-2-6 (9)(10) Shock Resis- tance IEC IEC 60068-2-27 (9)(10) Resistances to heat and fire Amplitude Range: 10-55 Hz, Displace- ment 0.75mm Peak Acceleration: 15g, Duration 11ms. IEC 60335-1, Section 30 Directive 2006/95/EC Directive 2011/65/EU GBT 26572-2011 Electromagnetic Compatibility Generic Standard Immunity Tests Test Specification Level Performance IEC 61000-6-2 Immunity for Industrial Envi- ronments" Electrostatic Discharge IEC 61000-4-2 8kV air discharge Criterion A 6kV contact discharge Criterion A Fast transient (burst) IEC 61000-4-4 Output 2kV, 5kHz, 100kHz Criterion B Input 1kV, 5kHz, 100kHz Criterion B Surge IEC 61000-4-5 Output 1kV Line to Line Criterion B 2kV Line to Earth Criterion B AC Input Option 1kV Line to Line Criterion A 2kV Line to Earth Criterion A (1) Option available upon demand. Please contact your local Sensata representative for additional information. (2) All parameters at 25°C unless otherwise specified per Channel. (3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads. (4) Increase minimum voltage by 1 V for operations from -20 to -40°C. (5) Turn-on time for Instantaneous turn-on versions is 0.1 msec. (6) When protected with the appropriate class and rated fuse. For detailed info please contact Sensata Technical Support. (7) No freezing or condensation allowed. (8) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by 2 (1.414). (9) Except when device is attached to a panel or flat surface with screws. (10) Test conditions: Din Rail stoppers side by side between a single SSR. GENERAL NOTES

+1 (877) 502 5500 – Option 2 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 www.sensata.com CONTACT USCopyright © 2019 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev:08/09/19 ERN 20741 FDE-07-01 Rev.B WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.