DR24D03 SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
Features
Applications
- Ratings of 3, 6 & 12 Amps
- Load voltage ratings of 24-280 VAC and 48-600 VAC
- Fits standard 35mm DIN Rail
- LED input status indicator
- AC or DC control
- Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output
- UL and cUL Listed, HP Rated, CE & RoHS Compliant
- UL 508 Endurance Rating for Enhanced Reliability
- UL Class I and II, Division 2, for Hazardous Locations
- Industrial ovens
- Plastic injection molding equipment
- Packaging equipment
- Professional cooking equipment
- Lighting control
- HVAC&R Sensata | Crydom SeriesOne DR family of DIN Rail mount Solid State Relays incorporate proprietary thermal management technology to achieve exceptional output ratings of 3, 6 and 12 Amps at 24 to 600 VAC in compact 11mm and 18mm wide housings. These compact SSRs are ideal for use in demanding applications where space may be limited, providing greater power density than other DIN Rail Solid State Relays. Control Voltage 280V, 3 A 280V, 6 A 280V, 12 A 600V, 3 A 600V, 6 A 600V, 12 A 4-32 VDC DR24D03 DR24D06 DR24D12 DR48D03 DR48D06 DR48D12 90-140 VAC DR24B03 DR24B06 DR24B12 DR48B12 200-280 VAC DR24A03 DR24A06 DR24A12 DR48A12 18-36 VAC DR24E03 DR24E06 DR24E12 DR48E12 PRODUCT SELECTION 3, 6 Amps
12 Amps
www.sensata.comCopyright © 2021 Sensata Technologies, Inc. Input (1) Description DRxxDxx DRxxBxx DRxxAxx DRxxExx Control Voltage Range (3) 4-32 VDC 90-140 Vrms 200-265 Vrms 18-36 Vrms (5) Minimum Turn-On Voltage 4.0 VDC 90 Vrms 200 Vrms 18 Vrms Must Turn-Off Voltage 1.0 VDC 10 Vrms 40 Vrms 4 Vrms Minimum Input Current for [mA] (4) 9 3 2.5 3.5 Maximum Input Current for [mA] (4) 11 5 3.3 8 Maximum Turn-on Time [msec] (5) 1/2 Cycle 20 msec 20 msec 20 msec Maximum Turn-off Time [msec] 1/2 Cycle 30 msec 30 msec 30 msec Min/Max stranded/solid wire 22/16 AWG 22/16 AWG 22/16 AWG 22/16 AWG SPECIFICATIONS Output (1) Description DR24x03 DR24x06 DR24x12 DR48x03 DR48x06 DR48X12 Operating Voltage Range (47-63Hz) [Vrms] 24-280 24-280 24-280 48-600 48-600 48-600 Transient Overvoltage [Vpk] 600 600 600 1200 1200 1200 Maximum Load Current, resistive [Arms] (2) 3 6 12 3 6 12 Minimum Load Current [mArms] 150 150 150 150 150 150 Maximum Off-State Leakage Current @ Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] (3) 500 500 500 500 500 500 Maximum On-State Voltage Drop @ Rated Maximum Surge Current (50/60Hz, 1 cycle) [Apk] 285/300 285/300 715/750 285/300 285/300 715/750 Maximum I²t for Fusing (50/60 Hz, 1/2 cycle) [A² sec] 410/375 410/375 2560/2330 410/375 410/375 2560/2330 HP Rating UL 508/IEC60947 [HP (KW)] @ HP Rating UL 508/IEC60947 [HP (KW)] @ HP Rating UL 508/IEC60947 [HP (KW)] @ Min/Max stranded wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Min/Max solid wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG
www.sensata.comCopyright © 2021 Sensata Technologies, Inc. General (2) Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz)
4000 Vrms
Minimum Insulation Resistance (@ 500 V DC)
109 Ohms
Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -30 to 80 °C Ambient Storage Temperature Range -30 to 100 °C Recommended Terminal Screw Torque Range MECHANICAL SPECIFICATIONS (1)
3 A , 6 A 12 A
EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS
www.sensata.comCopyright © 2021 Sensata Technologies, Inc. THERMAL DERATE INFORMATION Single and multiple units (for DRxxx03) Single unit, distance to adjacent components ≥ 11 mm for DRxxx06 and ≥ 18 mm for DRxxx12 Multiple units, no minimum spacing between components STANDARDS OF COMPLIANCE IEC 62314 LC A, Resistive or Slightly Inductive Load Ratings: 3A @40°C ambient for DR24x03, 3A @ 40°C ambient for DR48x03 LC A, Resistive or Slightly Inductive Load Ratings: 12 A @40°C ambient for DR24x12, 12 A @ 40°C ambient for DR48x12 LC A, Resistive or Slightly Inductive Load Ratings: 6 A @ 40°C ambient for DR24x06, 6 A @ 40°C ambient for DR48x06 LC B, Motor Loads Ratings: 0.18KW @ 240VAC for DR24x03 and 0.375KW @ 480VAC DR48x03 LC B, Motor Loads Ratings: 0.75KW @ 240 VAC for DR24x06 and 2.2KW @ 480 VAC DR48x12 LC B, Motor Loads Ratings: 0.375KW @ 240 VAC for DR24x06 and 1.5KW @ 480 VAC DR48x12 Shock and Vibration (Applies to all part numbers) Vibration Resistance according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz Shock Resistance according to IEC 60068-2-27: 15g/11ms EMC (Applies to all part numbers) IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ANSI / ISA 12.12.01-2013 Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for Class I, Division 2
www.sensata.comCopyright © 2021 Sensata Technologies, Inc. Series DR Operating Voltage 24: 24-280 VAC 48: 48-600 VAC Control Voltage D: 4-32 VDC A: 200-265 VAC B: 90-140 VAC E: 18-36 VAC (1) Rated Load Current 03: 3 Amps 06: 6 Amps 12: 12 Amps ATEX Approvals Blank: Not ATEX approved X: ATEX II 3G Ex nA IIC T4 Gc approved Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On (D suffix Only) ORDERING OPTIONS Example : DR24D12R Required for valid part number For options only and not required for valid part number (1) All parameters at 25°C unless otherwise specified. (2) See Derating curves (3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (4) DC control includes reverse polarity protection. (5) E option is UL certified for AC control voltage, but it works also with 18-36 VDC input range. (6) Input circuitry incorporates active current limiter. (7) Turn-on time for DC control random turn-on versions is 0.1 msec. GENERAL NOTES AGENCY APPROVALS & CERTIFICATIONS DR 24 D 12 X R
+1 (877) 502 5500 – Option 2 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Rev:05/28/2021 ECN 21137 FDE-07-01 Rev. B www.sensata.com CONTACT USCopyright © 2021 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. ACCESSORIES WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury. ID Marker Strips CNLB, CNLN, CNL2 Black Strips Part no.: CNLB Numbered 1 to 10 Strips Part no.: CNLN Numbered 11 to 20 Strips Part no.: CNL2 A package of 10 plastic strips comprising 10 individual unprinted markers which can be placed on sockets’ terminal block for easy identification during the use of multiple units. A package of 10 plastic strips comprising 10 markers printed individually from 1 to 10 which can be placed on sockets’ terminal block for easy identification during the use of multiple units. A package of 10 plastic strips comprising 10 markers printed individually from 11 to 20 which can be placed on sockets’ terminal block for easy identification during the use of multiple units.