DR06D12XR_17 CRYDOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

  • Ratings of 6 & 12 Amps
  • Load voltage ratings of 1-60 VDC, 1-100 VDC, 24-280 VAC and 48-600 VAC
  • Fits standard 35mm DIN Rail
  • LED input status indicator
  • AC or DC control
  • Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output
  • UL and cUL Listed, HP Rated CE & RoHS Compliant
  • UL 508 Endurance Rating for Enhanced Reliability
  • UL Class I and II, Division 2, for Hazardous Locations PRODUCT SELECTION Control Voltage 280, 6 A 280V, 12 A 600V, 6 A 600V, 12 A 60V, 6 A 60V, 12 A 100V, 6 A 100V, 12 A 4-32 VDC DR24D06 DR10D12 90-140 VAC DR24B06 200-280 VAC DR24A06 AVAILABLE OPTIONS OUTPUT SPECIFICATIONS AC Output (2) Description DR24x06 DR24x12 DR48x06 DR48X12 Operating Voltage Range (47-63Hz) [Vrms] 24-280 24-280 48-600 48-600 Transient Overvoltage [Vpk] 600 600 1200 1200 Maximum Load Current, resistive [Arms] (3) 6 12 6 12 150 150 150 150 0.1 0.1 0.1 0.1 Minimum Load Current [mArms] 500 500 500 500 Maximum Surge Current (50/60Hz, 1 cycle) [Apk] 1.3 1.3 1.3 1.3Maximum On-State Voltage Drop @ Rated Current [Vrms] 285/300 715/750 285/300 715/750 400/375 2560/2330 410/375 2560/2330Maximum I²t for Fusing (50/60 Hz, 1/2 cycle) [A² sec] 18-36 VAC DR24D12 DR24B12 DR24A12 DR48D06 DR48B12 DR48E12 DR48A12 DR48D12 DR06D06 DR06D12 DR10D06 DR24E06 DR24E12 AC Output Only Series Operating Voltage 06: 1-60 VDC 10: 1-100 VDC 24: 24-280 VAC 48: 48-600 VAC Rated Load Current 06: 6 Amps 12: 12 Amps Control Voltage D: 4-32 VDC A: 200-265 VAC B: 90-140 VAC E: 18-36 VAC (1)

1206 DDR X

X: ATEX II 3G Ex nA IIC T4 Gc approved Switching Type Blank: Zero Voltage Turn-On (AC Output Only) R: Instantaneous Turn-On (AC Output, D suffix Only) R Required for valid part number For options only and not required for valid part number Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (4) HP Rating UL 508/IEC60947 [HP (KW)] @ 240V Minimum Power Factor (at Maximum Load) Min/Max stranded wire HP Rating UL 508/IEC60947 [HP (KW)] @ 380V HP Rating UL 508/IEC60947 [HP (KW)] @ 480V Min/Max solid wire Weight (Typical) 0.5 0.5 0.5 0.5 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG22/14 AWG 22/14 AWG 22/14 AWG Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DCAC

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. INPUT SPECIFICATIONS (2) DRxxExxDRxxBxxDRxxDxxDescription Control Voltage Range (5) 4-32 VDC 200-265 Vrms 18-36 Vrms (1) Minimum Turn-On Voltage 4.0 VDC 200 Vrms 18 Vrms Must Turn-Off Voltage 1.0 VDC 40 Vrms 4 Vrms Minimum Input Current for [mA] (6) 9 2.5 3.5 Maximum Input Current for [mA] (6) 11 3.3 8 1/2 Cycle 20 msec 20 msecMaximum Turn-on Time [msec] (7) (8) 1/2 Cycle 30 msec 30 msecMaximum Turn-off Time [msec] (9) 22/16 AWG 22/16 AWG 22/16 AWG GENERAL SPECIFICATIONS(2) Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms (10) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -30 to 80 °C Ambient Storage Temperature Range -30 to 100 °C Recommended Terminal Screw Torque Range

109 Ohm

OUTPUT SPECIFICATIONS DC Output (2) Description DR06D06 DR10D06 DR06D12 DR10D12 Operating Voltage [VDC] 1-60 1-100 1-60 1-100 Maximum Load Current [Adc] (3) 6 6 12 12 Minimum Load Current [mAdc] 2.5 2.5 2.5 2.5 0.1 0.1 0.1 0.1 0.6 0.6 0.6 0.6 Maximum Off-State Leakage Current @ Rated Voltage [mA] Maximum On-State Voltage Drop @ Rated Current [Vpk] 60 60 On-State resistance at rated current [Ohms] 0.1 0.1 Min/Max stranded wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Min/Max solid wire Weight (typical) Maximum Surge Current (10ms) [Apk] 100 100 0.45 22/14 AWG 22/14 AWG 3.17 oz (90g) 0.45 22/14 AWG 3.17 oz.(90g) 22/14 AWG Min/Max stranded/solid wire DRxxAxx 90-140 Vrms

90 Vrms

10 Vrms

(2) All parameters at 25°C unless otherwise specified. (1) E option is UL certified for AC control voltage, but it works also with 18-36 VDC input range. (3) See Derating curves (4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (5) DC control includes reverse polarity protection. (6) Input circuitry incorporates active current limiter. (7) Turn-on time for DC control random turn-on versions is 0.1 msec. (8) Turn-on time for DC output 600 µsec. (9) Turn-off time for DC output 300µsec. (10) 2500Vrms for DC output. LC A, Resistive or Slightly Inductive Load Ratings: 12 A @40°C ambient for DR24x12, 12 A @ 40°C ambient for DR48x12 LC A, Resistive or Slightly Inductive Load Ratings: 6 A @ 40°C ambient for DR24x06, 6 A @ 40°C ambient for DR48x06 LC B, Motor Loads Ratings: 0.75KW @ 240 VAC for DR24x06 and 2.2KW @ 480 VAC DR48x12 LC B, Motor Loads Ratings: 0.375KW @ 240 VAC for DR24x06 and 1.5KW @ 480 VAC DR48x12 Standards of Compliance IEC 62314 Shock and Vibration (Applies to all part numbers) Vibration Resistence according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz Shock Resistance according to IEC 60068-2-27: 15g/11ms EMC (Applies to all part numbers) IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ANSI / ISA 12.12.01-2013 Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for Class I, Division 2

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. MECHANICAL SPECIFICATIONS (2) EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS Installed single unit, distance to adjacent components ≥ 11 mm for DRxxx06 & ≥ 18mm for DRxxx12

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Rev 052516 100 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) DRxxx06 100 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) DRxxx12 Installed single unit, distance to adjacent components ≥ 11 mm for DRxxx06 & ≥ 18mm for DRxxx12 Multiple units, no minimum spacing between components AGENCY APPROVALS THERMAL DERATE INFORMATION E116949 IND. CONT. EQ. 4WB8

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. ACCESORIES

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • Disconnect all power before installing or working with this equipment.
  • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
  • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
  • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
  • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
  • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
  • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
  • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
  • Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
  • Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie 存在电击、 爆炸或电弧 闪烁危险
  • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
  • The product's side panels may be hot, allow the product to cool before touching.
  • Follow proper mounting instructions including torque values.
  • Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
  • Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
  • Respecter les consignes de montage, et notamment les couples de serrage.
  • Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
  • Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
  • Beachten Sie die Montageanweisungen,
  • Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
  • Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
  • Respetar las instrucciones de montaje, y en particular los pares de apretado.
  • No dejar que penetren líquidos o cuerpos extraños en el producto. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
  • I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
  • Seguire le istruzioni di montaggio corrette.
  • Non far entrare liquidi o oggetti estranei in questo apparecchio. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
  • 产品的一侧面板可能很热,在其冷却前请 不要触碰。
  • 遵照正确的安装说明,包括扭矩值。
  • 请勿让液体及其他异物进入本产品。

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点