Features
- Output ratings up to 32 Amps at 600 VAC
- Built-in overvoltage protection
- Contactor configuration
- Integral heat sink eliminates the need for complex thermal calculations
- DBC substrate for superior thermal performance
- IP20 touch-safe housing
- AC or DC control
- Relays are C-UL-US and TUV approved (see TABLE 3)
Applications
- Industrial ovens
- Plastic injection molding equipment
- Packaging equipment
- Professional cooking equipment
- Lighting control
- HVAC&R PRODUCT SELECTION SPECIFICATIONS Description 27 A 32 A Operating Voltage (47-440 Hz) [Vrms] 48-600 48-600 Transient Overvoltage [Vpk] (2) 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 1 1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/sec] 500 500 Load Current, General Use UL508/LC A IEC 62314 @ 40°C [Arms] 30 35 Minimum Load Current [mArms] 100 150 Maximum 1 Cycle Surge Current (50/60 Hz) [Apk] 716/750 1290/1350 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 1.30 Maximum 1/2 Cycle I²t for Fusing (50/60 Hz) [A²sec] 2563/2343 8320/7593 Minimum Power Factor (at Maximum Load) (4) 0.5 0.5 Output (1) Nova22 DR22C Series are last generation DIN Rail mount Solid State Relays in a 22.5mm wide industrial package. These SSRs come with an integral low depth heat sink and a robust back-to-back SCR output rated for up to 32 Amps at 600 VAC. This provides users with a compact solution to switch small and medium AC loads, allowing to reduce cabinet space without sacrificing performance. These powerful and ready to use SSRs are perfect for applications where the depth of the control panel is limited, and they are UL and TUV approved and CE compliant.
www.sensata.com Page 2 Copyright © 2024 Sensata Technologies, Inc. Description DR22C60DxxJ DR22C60AxxJ Control Voltage Range [VDC] 4-32 VDC (4) 90-280 VAC/VDC (4) Maximum Reverse Voltage -32 VDC - Minimum Turn-On Voltage 4 VDC 90 VAC/VDC Must Turn-Off Voltage 1 VDC 5 VAC/VDC Minimum Input Current (for on-state) 7 mA 6 mA Maximum Input Current 15 mA 10 mA Nominal Input Impedance Current Regulated Current Limited Maximum Turn-On Time [msec] 1/2 Cycle (6) 20 Maximum Turn-Off Time [msec] 1/2 Cycle 30 Description Parameters Dielectric Strength, Input to Output (50/60 Hz) 4000 Vrms Dielectric Strength, Input/Output to Case (50/60 Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -40 to 80 °C Ambient Storage Temperature Range -40 to 100 °C Weight (typical) 9.17 oz (260 g) Housing Material UL94 V-0 Heat Sink Material Aluminum DIN Rail Clip Material Zink Plated Steel Hardware Finish Nickel Plating Load Terminal Screw Torque Range (lb-in/Nm) 18-20 / 2-2.2 Humidity 95% non-condensing LED Input Status Indicator Green Input (1) General (2) ww w .sensata.com Page 3 Copyright © 2019 Sensata T echnologies, Inc. 4-32 VDC Input 90-280 VAC/VDC Input DR22C60x27J DR22C60x32J (8) DR22C60x27J DR22C60x32J 1 0 1 5 2 0 2 5 3 0 2 0 2 5 3 0 4 0 5 0 6 0 7 0 8 0 L o a d C u r r e n t ( A m p s ) A m b i e n t T e m p e r a t u r e ( °C ) S i n g l e u n i t M u l t i p l e u n i t s 1 0 1 5 2 0 2 5 3 0 3 5 2 0 2 5 3 0 4 0 5 0 6 0 7 0 8 0 L o a d C u r r e n t ( A m p s ) A m b i e n t T e m p e r a t u r e ( °C ) S i n g l e u n i t M u l t i p l e u n i t s INPUT CURRENT INFORMATION
www.sensata.com Page 3 Copyright © 2024 Sensata Technologies, Inc. ww w .sensata.com Page 3 Copyright © 2019 Sensata T echnologies, Inc. 4-32 VDC Input 90-280 VAC/VDC Input DR22C60x27J DR22C60x32J (8) DR22C60x27J DR22C60x32J 1 0 1 5 2 0 2 5 3 0 2 0 2 5 3 0 4 0 5 0 6 0 7 0 8 0 L o a d C u r r e n t ( A m p s ) A m b i e n t T e m p e r a t u r e ( °C ) S i n g l e u n i t M u l t i p l e u n i t s 1 0 1 5 2 0 2 5 3 0 3 5 2 0 2 5 3 0 4 0 5 0 6 0 7 0 8 0 L o a d C u r r e n t ( A m p s ) A m b i e n t T e m p e r a t u r e ( °C ) S i n g l e u n i t M u l t i p l e u n i t s ww w .sensata.com Page 3 Copyright © 2019 Sensata T echnologies, Inc. 4-32 VDC Input 90-280 VAC/VDC Input DR22C60x27J DR22C60x32J (8) DR22C60x27J DR22C60x32J 1 0 1 5 2 0 2 5 3 0 2 0 2 5 3 0 4 0 5 0 6 0 7 0 8 0 L o a d C u r r e n t ( A m p s ) A m b i e n t T e m p e r a t u r e ( °C ) S i n g l e u n i t M u l t i p l e u n i t s 1 0 1 5 2 0 2 5 3 0 3 5 2 0 2 5 3 0 4 0 5 0 6 0 7 0 8 0 L o a d C u r r e n t ( A m p s ) A m b i e n t T e m p e r a t u r e ( °C ) S i n g l e u n i t M u l t i p l e u n i t s SURGE CURRENT INFORMATION THERMAL DERATE INFORMATION (7) EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM ww w .sensata.com Page 4 Copyright © 2019 Sensata T echnologies, Inc. AD/DC Control DC Control
Copyright © 2024 Sensata Technologies, Inc. Please read all installation instructions before using your DR22C Series Solid State Relay (SSR).
- Install the relay on the DIN Rail (as shown in fig. 1)
- Maximum recommended terminal screw torque load terminal: 18-20 lb-in (2.0-2.2 Nm)
- If multiple units are installed be sure to follow derating curves
- To achieve maximum ratings, there must be a minimum spacing of 0.89 in (22.5 mm) between the devices in free air (as shown in fig. 2)
- Recommended wire sizes as shown in TABLE 1 WARNING! Removing product from 35 mm rail incorrectly by not using the appropriate tool would damage the latching system. SUD To install on DIN rail To remove on DIN rail fig.1 SSR mounted on DIN rail
TABLE 1. Recommended Wire Sizes standard not provided with SSR. TABLE 2. Compatible Terminals
Copyright © 2024 Sensata Technologies, Inc. TABLE 3. Assemblies Detail
www.sensata.com Page 6 Copyright © 2024 Sensata Technologies, Inc. ACCESSORIES Recommended Accessories Connectors ID Marker CP201 CP202 CNLB CNLN CNL2 AGENCY APPROVALS & CERTIFICATIONS Certification in accordance with: United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. TUV Certified in accordance to EN62314 Agency certifications are for relay only (not for complete assembly) Vibration Resistance: (10) IEC 60068-2-6: Amplitude Range 10-500 Hz, Displacement 0.75 mm Shock Resistance: (10) IEC 60068-2-27: Peak Acceleration 50g, Duration 11 ms. Electromagnetic Compatibility Generic Standard Inmunity Tests Test Specification Level Performance IEC 61000-6-2 Immunity for Industrial Environments Electrostatic Discharge IEC 61000-4-2 8 kV air discharge Criterion B 6 kV contact discharge Criterion A Fast transients (burst) IEC 61000-4-4 Output 2 kV, 5 kHz, 100 kHz Criterion B Input 1 kV, 5 kHz, 100 kHz Criterion B Surge IEC 61000-4-5 Output 1 kV Line to Earth Criterion B 2 kV Line to Earth Criterion B AC Input Option 1 kV Line to Earth Criterion B 2 kV Line to Earth Criterion B
www.sensata.com CONTACT US Americas +1 (800) 350 2727 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2024 Sensata Technologies, Inc. Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 11/19/2024 ECN 21163 FDE-07-01 Rev. B WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury. GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads. (3) High inductive loads requires nominal control voltage; AC input models only. (4) Increase minimum voltage by 1 V for operations from -20 to -40°C. (5) For ambient temperatures above 40°C the maximum control voltage must not exceed 220 VAC/VDC. (6) Turn-on time for Instantaneous turn-on versions is 0.1 msec. (7) AC input models operating range is -20 to 60 °C. (8) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by √2 (1.414). (9) Minimum spacing to obtain max. current is 22.5 mm between adjacent units. (10) Test made with a unit fixed between DIN RAIL Stoppers. Multiple devices mounted close each other, results may vary.