DR22_V01 SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
Features
- Output ratings up to 30 Amps at 280 VAC
- Relay configuration
- Compact 22.5 mm wide package
- Snubber circuit
- Built-in overvoltage protection
- IP20 touch-safe housing
- Wide 3-32 VDC control input
- Integrated low-profile heatsink
- C-UL-US approved
Applications
- Industrial ovens
- Plastic injection molding equipment
- Packaging equipment
- Professional cooking equipment
- Lighting control
- HVAC&R PRODUCT SELECTION SPECIFICATIONS Description 20 A 30 A Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 Transient Overvoltage [Vpk] (2) 600 600 Minimum Off-State dV/dt @ Maximum Rated Voltage [V/μsec] 500 500 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 2 2 Load Current, General Use UL508 @40°C [Arms] 20 30 Load Current, Motor Starting UL508 FLA @40°C [Arms] 9.8 13.8 Minimum Load Current [mArms] 100 100 Maximum 1 Cycle Surge Current (50/60 Hz) [Apk] 400/440 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.2 1.3 Output (1) Nova22 DR22 Series are last generation DIN Rail mount Solid State Relays in a 22.5mm wide industrial package. “Low-profile” versions come with an integral low-profile heat sink and a TRIAC output rated for up to 30 Amps at 280 VAC. This provides users with a cost-effective solution to switch small and medium AC loads that allows to reduce manufacturing cost and cabinet space without sacrificing performance, and to optimize equipment operation time. These powerful and ready to use SSRs are perfect for applications where the depth of the control panel is limited, and they are UL approved and CE compliant.
www.sensata.com Page 2 Copyright © 2023 Sensata Technologies, Inc. Description DR2224Dxxxx Control Voltage Range [VDC] (3) 3-32 Minimum Turn-On Voltage [VDC] 3 Must Turn-Off Voltage [VDC] 1 Minimum Input Current (for on-state) [mA] 8 Maximum Input Current [mA] 15 Nominal Input Impedance Current Regulated Maximum Turn-On Time (4) 1/2 Cycle Maximum Turn-Off Time 1/2 Cycle Maximum Turn-Off Time [μsec] 100 Description Parameters Dielectric Strength, Input to Output (50/60 Hz) 3750 Vrms Dielectric Strength, Input/Output to Case (50/60 Hz) 2500 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80 °C Ambient Storage Temperature Range -40 to 100 °C Weight (typical) 9.17 oz (260 g) Housing Material UL94 V-0 Heat Sink Material Aluminum DIN Rail Clip Material Zink Plated Steel Hardware Finish Nickel Plating Humidity 95% non-condensing Input and Output Terminal Screw Torque Range (lb-in/Nm) 13-15 / 1.5-1.7 LED Input Status Indicator Green Input (1) General (1) Maximum 1/2 Cycle I²t for Fusing (50/60Hz) [A²sec] 800/806 Motor Rating UL 508 [HP (kW)]: 120 VAC 0.5 (0.37) 0.75 (0.55) Motor Rating UL 508 [HP (kW)]: 240 VAC 1.5 (1.1) 2 (1.5)
www.sensata.com Page 3 Copyright © 2023 Sensata Technologies, Inc. SURGE CURRENT INFORMATION THERMAL DERATE INFORMATION Single units (5) Multiple units, no minimum spacing between components 11 100 2 10 3 100 200 300 400 500 number of cycles (n) ITSM (A) IT T j(init) = 25 ˚C max ITSM T t f = 50 Hz INPUT CURRENT INFORMATION 3-32V Control Current Amps Voltage DC Non-repetitive peak on-state current as a function of the number of sinusoidal current cycles; maximum values.
www.sensata.com Page 4 Copyright © 2023 Sensata Technologies, Inc. EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM *Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Load can be wired to either terminal 1 or terminal 2. Recommended Wire Sizes Terminal Configuration Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Output Relay “U” suffix 2 x 18 AWG (1 mm2) Stranded 20 [88] 2 x 10 AWG (6 mm2) Stranded 60 [266] Input Relay “U” suffix 2 x 18 AWG (1 mm2) Stranded 20 [88] 2 x 12 AWG (4 mm2) Stranded 40 [177] Compatible Terminal Terminal W D Fork Lug Width [W] in (mm) 0.45 (11.4) Stud Size Dia [D] (in) #8 (0.168) MECHANICAL SPECIFICATIONS Protective Earth Connection 10-32 Thread Protective Earth (PE) Screw Type recommended is 10-32 UNC standard not provided With SSR. Through the use if a DIN rail ground (protective conductor_ Therminal block, the DIN rail clip of DR22 models, permits as secure path to ground and avoid the need of further PE protection. ACCESSORIES Recommended Accessories ID Marker CNLB CNLN CNL2
www.sensata.com Page 5 Copyright © 2023 Sensata Technologies, Inc. AVAILABLE OPTIONS Example : DR2224D20UR DR22 24 D 20 U R Series DR22 Operating Voltage 24: 24-280 VAC Control Voltage D: 3-32 VDC Rated Load Current 20: 20 Amps 30: 30 Amps Terminal Layout U: Relay Configuration Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On (Motor Rating Certified) GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) Internal protection will activate between 440-540 Vpk, intended to protect power semiconductor for high frequency transient only. Internal damage can occur if device is operated beyond voltage limits. (3) Increase minimum voltage by 1 V for operations from -20 to -40°C. (4) Turn-on time for instantaneous turn-on versions is 0.1 msec. (5) Minimum spacing to obtain maximum current is 22.5mm between adjacent units. Required for valid part number For options only and not required for valid part number AGENCY APPROVALS & CERTIFICATIONS Certification in accordance with: United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. Electromagnetic Compatibility Generic Standard Inmunity Tests Test Specification Level Performance IEC 61000-6-2 Immunity for Industrial Environments Electrostatic Discharge IEC 61000-4-2 4kV air discharge Criterion A 4kV contact discharge Criterion A Fast transients (burst) IEC 61000-4-4 Output 2kV, 5kHz, 100kHz Criterion B Input 1kV, 5kHz, 100kHz Criterion B Surge IEC 61000-4-5 Output 1kV Line to Earth Criterion B 2kV Line to Earth Criterion B
www.sensata.com CONTACT US Americas +1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2023 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 03/01/2023 ECN 21163 FDE-07-01 Rev. B WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.