DR22 SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
Features
- O utput ratings up to 30 Amps at 200 VDC
- I ntegral heat sink eliminates the need for complex thermal calculations
- D BC substrate for superior thermal performance
- L ED input status indicator
- I P20 touch-safe housing
- 1 kHz Maximum PWM Frequency
- 3
750 VAC optical isolation
- C -UL-US approved PRODUCT SELECTION Description 20 A 30 A Absolute Maximum Rating [VDC] 200 200 Recommended Operating Voltage [VDC] 1-150 1-150 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.2 Load Current, DC General Use UL508 @ 40°C [ADC] 20 30 Load Current, DC Motor Starting UL508 FLA @ 40°C [ADC] 4.1 5.4 Minimum Load Current [mA] 2 5 5 Maximum Surge Current [ADC] (10ms) 58 86 Maximum On-State Voltage Drop @ Rated Current [VDC] 0.680 0.535 Maximum On-State Resistance [RDS-ON][Ohms] 0.034 0.016 Maximum Pulse Width Modulation Frequency [Hz] 3 1000 900 Motor Rating UL 508 [HP (kW)]: 120 VDC 1/3 (0.25) 1/2 (0.37) SPECIFICATIONS Output (1)
www.sensata.com Page 2 Copyright © 2018 Sensata Technologies, Inc. Description DC Control Control Voltage Range 4-32 VDC Maximum Reverse Voltage -32 VDC Minimum Turn-On Voltage 4 4 VDC Must Turn-Off Voltage 1 VDC Minimum Input Current (for on-state) 11 mA Maximum Input Current 15 mA Nominal Input Impedance Current Regulated Maximum Turn-On Time [μsec] 75 Maximum Turn-Off Time [μsec] 100 Description Parameters Dielectric Strength, Input to Output (50/60Hz) 3750 Vrms Dielectric Strength, Input/Output to Case (50/60Hz) 2500 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80 °C Ambient Storage Temperature Range -40 to 100 °C Weight (typical) 10.5 oz (298 g) Housing Material UL94 V-0 Heat Sink Material Aluminum Din Rail Clip Material Zinc Plated Steel Hardware Finish Nickel Plating Input Terminal Screw Torque Range (lb-in/Nm) 13-15/1.5-1.7 Load Terminal Screw Torque Range (lb-in/Nm) 13-15/1.5-1.7 Humidity 95% non-condensing LED Input Status Indicator Green Input (1) General (1)
www.sensata.com Page 3 Copyright © 2018 Sensata Technologies, Inc. INPUT CURRENT INFORMATION SURGE CURRENT INFORMATION THERMAL DERATE INFORMATION 4-32 VDC Input DR2220D20U DR2220D30U DR2220D20U DR2220D30U
www.sensata.com Page 4 Copyright © 2018 Sensata Technologies, Inc. EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM *Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Load can be wired in position A or B inductive loads must be diode suppressed. Recommended Wire Sizes Terminal Configuration Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Output Relay “U” suffix 2 x 18 AWG (1 mm2) Stranded 20 [88] 2 x 10 AWG (6 mm2) Stranded 60 [266] Input Relay “U” suffix 2 x 18 AWG (1 mm2) Stranded 20 [88] 2 x 12 AWG (4 mm2) Stranded 40 [177] MECHANICAL SPECIFICATIONS Protective Earth Connection Protective Earth (PE) screw type recommended is 10-32 UNC standard not provided with SSR. Through the use of a DIN rail ground (protective conductor) terminal block, the DIN rail itself can be used as the grounding bus bar. In this case, the zinc plated steel material used for the DIN rail clip of DR22 models, permits a secure path to ground and avoid the need of a further PE connection. 10-32 Thread
www.sensata.com Page 5 Copyright © 2018 Sensata Technologies, Inc. ORDERING OPTIONS Example : DR2220D20U DR22 20 D 20 U Series DR22 Operating Voltage 20: 1-200 VDC Control Voltage D: 4-32 VDC Rated Load Current 20: 20 Amps 30: 30 Amps Terminal Layout U: Relay Configuration GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) Low current loads and high ambient temperature can affect turn-on time. (3) 8 VDC Minimum control voltage. Resistive loads only. Consider switching losses; at maximum frequency reduce to 75% output current. Recommended suppressor diode connected at load side, see wiring diagram. (4) Increase minimum voltage by 1 V for operations from -20 to -40°C. (5) Minimum spacing to obtain max. current is 22.5mm between adjacent units. Required for valid part number For options only and not required for valid part number ACCESSORIES Recommended Accessories ID Marker CNLB CNLN CNL2
www.sensata.com CONTACT US Americas +1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2019 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 09/10/19 ECN 20756 FDE-07-01 Re v. C WARNINGS AGENCY APPROVALS & CERTIFICATIONS Certification in accordance with: United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. Electromagnetic Compatibility Generic Standard Inmunity Tests Test Specification Level Performance IEC 61000-6-2 Immunity for Industrial Environments Electrostatic Discharge IEC 61000-4-2 4kV air discharge Criterion A 4kV contact discharge Criterion A Fast transients (burst) IEC 61000-4-4 Output 2kV, 5kHz, 100kHz Criterion B Input 1kV, 5kHz, 100kHz Criterion B Surge IEC 61000-4-5 Output 1kV Line to Earth Criterion B 2kV Line to Earth Criterion B RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.