AC Output DIN Rail Mount SSRs  Output ratings up to 35 Amps at 600 VAC  Built-in overvoltage protection  Relay or Contactor configuration  Integral heat sink eliminates the need for complex thermal calculations  DBC substrate for superior thermal performance  "Elevator" screw option to allow the use of ring or lug type terminals  IP20 touch-safe housing  AC or DC control  C-UL-US Listed and TUV approved PRODUCT SELECTION Control Voltage 20A 90-280 VAC/VDC DR2260A20x 4-32 VDC DR2260D20x 18-52 VAC/VDC DR2260U20x 30A DR2260A30x DR2260D30x DR2260U30x 35A DR2260A35x DR2260D35x DR2260U35x AVAILABLE OPTIONS Required for valid part number For options only and not required for valid part number Operating Voltage 60: 48-600 VAC Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On (Motor Rating Certified) Control Voltage (1) A: 90-280 VAC/VDC D: 4-32 VDC Series DR22 60 A R Rated Load Current 20: 20 Amps 30: 30 Amps 35: 35 Amps [High I2t] U Terminal Layout U: Relay Configuration V: Contactor Configuration (std. screw) W: Contactor Configuration (elevator screw) Input Connector Blank: Screw Terminal J: Spring Terminal (V and W suffixes only) V20 J OUTPUT SPECIFICATIONS (2) Description 30A Operating Voltage (47-440Hz) [VRMS] 48-600 Transient Overvoltage [Vpk] (3) 1200 Maximum Off-State Leakage Current @ Rated Voltage [mARMS] 1 Minimum Off-State dV/dt @ Maximum Rated Voltage [V//uni03BCsec] 500 Load Current, General Use UL508/LC A IEC62314 @ 40°C [ARMS] 30 Minimum Load Current [mARMS] 100 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 716/750 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 2563/2343 35A20A 48-600 48-600 1200 1200 1 1 500 500 20 35 Load Current, Motor Starting UL508 FLA/LC B IEC62314 @ 40°C [ARMS] 14/7.68.5/4.8 26/14 100 150 286/300 1290/1350 1.35 1.3 409/375 8320/7593 Minimum Power Factor (at Maximum Load) 0.50.5 0.5 Motor Rating UL 508/IEC62314 [HP (kW)]: 120 VAC 1 (0.74)0.5 (0.37) 2 (1.5) Motor Rating UL 508/IEC62314 [HP (kW)]: 240 VAC 3 (2.2)1.5 (1.1) 5 (3.73) Motor Rating UL 508/IEC62314 [HP (kW)]: 480 VAC 5 (3.7)3 (2.24) 10 (7.4) INPUT SPECIFICATIONS (2) Description DR2260Axxx Control Voltage Range 90-280 VAC/VDC Maximum Reverse Voltage - Minimum Turn-On Voltage 90 VAC/VDC Must Turn-Off Voltage 5 VAC/VDC Minimum Input Current (for on-state) 6 mA Maximum Input Current 10 mA Nominal Input Impedance Current Limited Maximum Turn-On Time [msec] 20 Maximum Turn-Off Time [msec] 30 DR2260Dxxx 4-32 VDC -32 VDC

4 VDC

1 VDC

(4) (5) (6) DataSheetDIN Rail Mount Do not forget to visit us at: www.crydom.com Copyright © 2015 Crydom Inc. Specifications subject to change without notice.

GENERAL SPECIFICATIONS (2) ParametersDescription Dielectric Strength, Input to Output (50/60Hz) 4000 VRMS Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Dielectric Strength, Input/Output to Case (50/60Hz) 4000 VRMS Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -40 to 80 °C Ambient Storage Temperature Range -40 to 100 °C Short Circuit Current Rating (8) 100kA Weight (typical) Option “U” 10.5 oz (298 g), Option “V”,“W” 10.6 oz (301 g) Housing Material UL94 V-0 Heat Sink Material Aluminum Hardware Finish Nickel Plating Input Terminal Screw Torque Range (in-lb/Nm) Option “U” 13-15/1.5-1.7, Option “V”,“W” 5/0.5 Load Terminal Screw Torque Range (in-lb/Nm) Option “U” 13-15/1.5-1.7, Option “V”,“W” 18-20/2-2.2 Humidity 85% non-condensing LED Input Status Indicator Green (9) INPUT CURRENT INFORMATION 0 5 10 15 20 25 30 35 4-32 VDC Input Input Current (mA) Input Voltage (VDC) 0 40 80 120 160 200 240 280 90-280 VAC/VDC Input Input Current (mA) Input Voltage (VAC/VDC) Do not forget to visit us at: www.crydom.com Copyright © 2015 Crydom Inc. Specifications subject to change without notice. SURGE CURRENT INFORMATION Single Pulse (10) 100 150 200 250 300 0.01 0.1 1 10 Surge Current (Amp) AC Peak Surge Duration (sec) DR2260x20x 100 200 300 400 500 600 700 0.01 0.1 1 10 Surge Current (Amp) AC Peak Surge Duration (sec) DR2260x30x 200 400 600 800 1000 1200 1400 0.01 0.1 1 10 Surge Current (Amp) AC Peak Surge Duration (sec) DR2260x35x DataSheetDIN Rail Mount

Do not forget to visit us at: www.crydom.com Copyright © 2015 Crydom Inc. Specifications subject to change without notice. EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM DC Trigger Circuit Current Limiter AC -4/A2 V +3/A1 2/T1 1/L1 INPUT OUTPUT V Load Load A B Load can be wired in position A or B AC/DC Trigger Circuit Current Limiter INPUT AC/DC Converter OUTPUT ACV Load Load A B V Load can be wired in position A or B +3/A1 -4/A2 1/L1 2/T1 Recommended Wire Sizes Terminal Configuration Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Output/Input (12) Relay “U” suffix Output Contactor suffixes Input Contactor suffixes

18 AWG (1 mm 2) Stranded

10 AWG (6 mm 2) Stranded

20 AWG (0.5 mm 2) [minimum] 2 x 10 AWG (5.3 mm 2) 2 x 8 AWG (8.4 mm 2) [maximum] 30 AWG (0.2 mm 2) [minimum] 12 AWG (2.5 mm 2) [maximum] 26 AWG (0.2 mm 2) [minimum] 12 AWG (2.5 mm 2) [maximum] 20 [88] 60 [266] 25 [111] 110 [490] 90 [400] 4.5 [20] 55 [245] 5 [22] 20 [89] Screw Spring DC Control AC/DC Control THERMAL DERATE INFORMATION 20 30 40 50 60 70 80 Load Current (Amps) Ambient Temperature (ºC) DR2260x35x Single unit (11) Multiple units 20 30 40 50 60 70 80 Load Current (Amps) Ambient Temperature (ºC) DR2260x30x Single unit (11) Multiple units 20 30 40 50 60 70 80 Load Current (Amps) Ambient Temperature (ºC) DR2260x20x Single unit (11) Multiple units (7)

Copyright © 2015 Crydom Inc. Specifications subject to change without notice. TABLE 1. Compatible Terminals TABLE 1 for Compatible Terminals.

Do not forget to visit us at: www.crydom.com Copyright © 2015 Crydom Inc. Specifications subject to change without notice. ACCESSORIES Rev. 100715 GENERAL NOTES (1) Control voltage 18-52 VAC/VDC is available upon request. (2) All parameters at 25°C unless otherwise specified. (3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads. (4) Increase minimum voltage by 1 V for operations from -20 to -40°C. (5) For ambient temperatures above 40°C the maximum control voltage must not exceed 250 VAC/VDC. (6) Turn-on time for Instantaneous turn-on versions is 0.1 msec. (7) AC input models operating range is -20 to 60 °C. (8) When protected with the appropriate class and rated fuse. For detailed info please contact Crydom Technical Support. (9) Input torque only for contactor (V,W) with screw terminals Connector. (10) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by √2 (1.414). (11) Minimum spacing to obtain max. current is 22.5mm between adjacent units. (12) For 35 Amp Relay (”U”) layout models, use Pin Terminals (L 0.410 in x Ø 0.102 in) to install 8 AWG wire. Lug TerminalID Marker Recommended Accessories CNLB CNLN CNL2 Connectors CP201 CP202 TRM0 TRM6 New Accessories! Connectors Part number: CP201, CP202 Pluggable input connectors, 2 position, with screw terminals (CP201) or spring type terminals (CP202). Compatible with Contactor Configuration NOVA22 SSRs. Lug Terminal Part number: TRM0 Copper wire lug for AWG 6 (13.3 mm²) to AWG 0 (53.5 mm²) wire size. For use with "Elevator" screw option ("W" suffix) NOVA22 SSRs. NOVA22 series has Environmental Product declarations type III conforming to ISO 14025. E116949 AGENCY APPROVALS United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. TUV Certified in accordance to EN62314 Electromagnetic Compatibility: IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 Vibration Resistance: IEC 60068-2-6: Amplitude Range 10-55 Hz, Displacement 0.75mm Shock Resistance: IEC 60068-2-27: Peak Acceleration 15g, Duration11ms. Certification in accordance with:

DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • Disconnect all power before installing or working with this equipment.
  • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
  • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
  • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
  • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
  • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
  • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
  • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
  • Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
  • Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie 存在电击、 爆炸或电弧 闪烁危险
  • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / ࠂܯ RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE  The product's side panels may be hot, allow the product to cool before touching.  Follow proper mounting instructions including torque values.  Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER  Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.  Respecter les consignes de montage, et notamment les couples de serrage.  Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG  Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.  Beachten Sie die Montageanweisungen,  Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD  Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.  Respetar las instrucciones de montaje, y en particular los pares de apretado.  No dejar que penetren líquidos o cuerpos extraños en el producto. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO  I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.  Seguire le istruzioni di montaggio corrette.  Non far entrare liquidi o oggetti estranei in questo apparecchio. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性  产品的一侧面板可能很热,在其冷却前请 不要触碰。  遵照正确的安装说明,包括扭矩值。  请勿让液体及其他异物进入本产品。 Do not forget to visit us at: www.crydom.com Copyright © 2015 Crydom Inc. Specifications subject to change without notice. DataSheetDIN Rail Mount

ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder Ќྐ༏ ሰྛြѓሙ4+5 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 Do not forget to visit us at: www.crydom.com Copyright © 2015 Crydom Inc. Specifications subject to change without notice. DataSheetDIN Rail Mount