DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 1/16 OPTREX Type No. Apr 9, 1999 First Edition Final Revision Quality Assurance Div. Production Div. Checked by Checked by Approved by Production Div. Design Engineering Div. Prepared by LCD Module Specification DMC16105NY-LYDMC16105NY-LYDMC16105NY-LYDMC16105NY-LY Table of Contents
Revision History
Rev. Date Page Comment
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 2/16 OPTREX 1.General Specifications Operating Temp. : min. 0 ℃ ~ max. 50 ℃ Storage Temp. : min. -20 ℃ ~ max. 70 ℃ Display Format : 16 characters × 1 line Display Fonts : 5 × 8 dots ( 1 character ) Viewing Area : 64.5 (W) × 13.0 (H) mm Outline Dimensions : 80.0 (W) × 36.0 (H) × 15.0 max. (D) mm Weight : 45g max. LCD Type : NTD-7305 ( STN / Yellow-mode / Transmissive ) Viewing Angle : 6:00 Backlight : LED Backlight / Yellow-green Drawings : Dimensional Outline UE-32055C
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 3/16 OPTREX 2.Electrical Specifications 2.1.Absolute Maximum Ratings VSS=0V Parameter Symbol Conditions Min. Max. Units Supply V oltage (Logic) VCC-VSS - -0.3 7.0 V Supply V oltage (LCD Drive) VCC-VEE - 0 13.0 V Input V oltage V I - -0.3 V CC+0.3 V 2.2.DC Characteristics Ta=25℃, VSS=0V Parameter Symbol Conditions Min. Typ. Max. Units Supply V oltage (Logic) VCC-VSS - 4.5 - 5.5 V Supply V oltage (LCD Drive) VCC-VEE Shown in 3.1 V High Level Input V oltage VIH V CC=5.0V±10% 2.2 - V CC V Low Level Input V oltage VIL V CC=5.0V±10% 0 - 0.6 V High Level Output V oltage VOH I OH=-0.205mA 2.4 - V CC V Low Level Output V oltage VOL I OL=1.2mA 0 - 0.4 V Supply Current I CC V CC-VSS=5.0V - 1.8 2.5 mA
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 4/16 OPTREX 2.3.AC Characteristics VCC=5.0V±10% Parameter Symbol Conditions Min. Max. Units Enable Cycle Time tCYC Fig.1, 2 500 - ns Enable Pulse Width PW EH Fig.1, 2 230 - ns Enable Rise/Fall Time tEr, tEf Fig.1, 2 - 20 ns Address Setup Time tAS Fig.1, 2 40 - ns Address Hold Time tAH Fig.1, 2 10 - ns Write Data Setup Time tDSW Fig.1 80 - ns Write Data Hold Time tDHW Fig.1 10 - ns Read Data Delay Time tDDR Fig.2 - 160 ns Read Data Hold Time tDHR Fig.2 5 - ns Fig.1 Write Operation Timing Fig.2 Read Operation Timing E R/W VIH VIL PWEH VIL tCYC tEr tEf tDSW tDHW tAHtAS VIL RS DB0~DB7 Valid Data VIH VIL VIH VIL VIH VILVIL VIH VIL VIH VIL E R/W VIHVIH VIH PWEH tDDR tEf tCYC tDHR tEr tAHtAS VIL RS DB0~DB7 Valid Data VIH VIL VIH VIL VIH VILVIL VOH VOL VOH VOL
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 5/16 OPTREX 2.4.Lighting Specifications 2.4.1.Absolute Maximum Ratings Ta=25℃ Parameter Symbol Conditions Min. Typ. Max. Units Foward Current I F Note 1 - - 275 mA Reverse V oltage V R - - - 8 V LED Power Dissipation P D - - - 1.2 W Note 1 : Refer to the foward current derating curve. 2.4.2.Operating Characteristics Ta=25℃ Parameter Symbol Conditions Min. Typ. Max. Units Foward V oltage V F I F = 110mA 3.8 4.0 4.2 V Luminance of Backlight Surface L I F = 110mA 80 - - cd/ ㎡
50250 Ta (℃)
IF (mA)
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 6/16 OPTREX 3.Optical Specifications 3.1.LCD Driving Voltage Parameter Symbol Conditions Min. Typ. Max. Units Recommended Ta= 0 ℃ - - 5.3 V LCD Driving V oltage V CC-VEE Ta=25 ℃ 4.4 4.7 5.0 V Note 1 Ta=50 ℃ 4.1 - - V Note 1 : V oltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range. 3.2.Optical Characteristics Ta=25℃, 1/16 Duty, 1/5 Bias, V D=4.7V (Note 4), θ= 0 ゚, φ=-゚ Parameter Symbol Conditions Min. Typ. Max. Units Contrast Ratio Note 1 CR θ= 0 ゚, φ=-゚ - 8 - Viewing Angle Shown in 3.3 Response Rise Note 2 T ON - - 120 200 ms Time Decay Note 3 T OFF - - 200 300 ms Note 1 : Contrast ratio is definded as follows. CR = LOFF / LON LON : Luminance of the ON segments LOFF : Luminance of the OFF segments Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 : Definition of Driving V oltage VD Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage V D is definded as follows. VD = (Vth1+Vth2) / 2 Vth1 : The voltage VO-P that should provide 50% of the saturation level in the luminance at the segment which the ON signal is applied to. Vth2 : The voltage VO-P that should provide 50% of the saturation level in the luminance at the segment which the OFF signal is applied to. VO-P 1 / fF ( B-2 )×VO-P / B 1 / ( fF×A ) 〈OFF SIGNAL〉〈ON SIGNAL〉
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 7/16 OPTREX 3.3.Definition of Viewing Angle and Optimum Viewing Area ・Point ● shows the point where contrast ratio is measured. : θ= 0 ゚, φ=-゚ ・Driving condition : 1/16 Duty, 1/5 Bias, VD=4.7V , fF=84.4Hz ・A r e a s h o w s t y p . C R≧2 3.4.System Block Diagram 90゚ 180゚ 270゚ θ φ 270゚ 135゚ 315゚225゚ 45゚ 180゚ 90゚ θ (φ= 0゚) φ 10 20 30 40 50 φ Halogen bulb Computer Rotation Table (θ,φ) Temperature Chamber LCD Optical Fiber Waveform Generator Control Unit & #1980A WB Photometer θ
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 8/16 OPTREX 4.I/O Terminal 4.1.Pin Assignment No. Symbol Level Function
1 V SS - Power Supply (0V , GND) & LED Cathode Terminal
2 V CC - Power Supply for Logic
3 V EE - Power Supply for LCD Drive
4 RS H / L Register Select Signal
5 R/W H / L H : Read L : Write
6 E H, H →L Enable Signal (No pull-up Resister)
7 DB0 H / L Data Bus Line / Non-connection at 4-bit operation
8 DB1 H / L Data Bus Line / Non-connection at 4-bit operation
9 DB2 H / L Data Bus Line / Non-connection at 4-bit operation
10 DB3 H / L Data Bus Line / Non-connection at 4-bit operation
11 DB4 H / L Data Bus Line
12 DB5 H / L Data Bus Line
13 DB6 H / L Data Bus Line
14 DB7 H / L Data Bus Line
15 LED : Anode - LED Anode Terminal
4.2.Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. MODULE VCC VEE VSS VCC (+Voltage) VR=10~20KΩ VSS (0V) VR
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 9/16 OPTREX 4.3.Block Diagram E RS R/W Control LSI or equivalent HD44780 L C D P 16 characters × 1 line LED Backlight DB7 DB0 Cathode SEG 40 COM 8 LED : Anode VEE VSS VCC To LSIBias Circuit SEG 40 COM 8
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 10/16 OPTREX 5.Test No change on display and in operation under the following test condition. No. Parameter Conditions Notes
1 High Temperature Operating 50 ℃±2℃, 96hrs (operation state)
2 Low Temperature Operating 0 ℃±2℃, 96hrs (operation state) 3
3 High Temperature Storage 70 ℃±2℃, 96hrs 4
4 Low Temperature Storage -20 ℃±2℃, 96hrs 3, 4
5 Damp Proof Test 40 ℃±2℃, 90~95%RH, 96hrs 3, 4
6 Vibration Test Total fixed amplitude : 1.5mm 5 Vibration Frequency : 10 ~55Hz One cycle 60 seconds to 3 directions of X, Y , Z for each 15 minutes
7 Shock Test To be measured after dropping from 60cm high on
the concrete surface in packing state. Note 1 : Unless otherwise specified, tests will be conducted under the following condition. Temperature : 20 ±5℃ Humidity : 65 ±5% Note 2 : Unless otherwise specified, tests will be not conducted under functioning state. Note 3 : No dew condensation to be observed. Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 5 : Vibration test will be conducted to the product itself without putting it in a container. E A G D C F 60cm Concrete Surface Dropping method corner dropping E,F,G face : once B,C,D edge : once A corner : once Face dropping Edge dropping B
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 11/16 OPTREX 6.Appearance Standards 6.1.Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45 ゚against perpendicular line. 6.2.Definition of applicable Zones A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area A Zone B Zone C Zone Bezel Flame 45゚
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 12/16 OPTREX 6.3.Standards No. Parameter Criteria
1 Black and (1) Round Shape
White Spots, Zone Acceptable Number Foreign Substances Dimension (mm) A B C D ≦ 0.1 * * * 0.3 < D 0 0 * D = ( Long + Short ) / 2 * : Disregard (2) Line Shape Zone Acceptable Number X(mm) Y(mm) A B C 2.0 ≧L 0.03 ≧W 3 3 * 1.0 ≧L 0.04 ≧W 1 2 * 1.0 ≧L 0.05 ≧W 0 2 * - 0.05 <W In the same way (1) X : Length Y : Width * : Disregard Total defects shall not exceed 5.
2 Air Bubbles
(between glass Zone Acceptable Number & polarizer) Dimension (mm) A B C D ≦0.15 * * * 0.3 < D ≦0.5 1 2 * 0.5 < D ≦1.0 0 1 * * : Disregard Total defects shall not exceed 3.
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 13/16 OPTREX No. Parameter Criteria
3 The Shape of Dot (1) Dot Shape (with Dent)
As per the sketch of left hand. (2) Dot Shape (with Projection) Should not be connected to next dot. (3) Pin Hole (X+Y) / 2 ≦0.2mm (Less than 0.1mm is no counted.) Total defects shall not exceed 5. 4 Polarizer Scratches Not to be conspicuous defects.
5 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not
defective. 6 Color Variation Not to be conspicuous defects. 0.15≧ Y X
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 14/16 OPTREX 7.Code System of Production Lot The production lot of module is specified as follows : Factory Number Factory Code (Alphabet) Production Week (1~5) Production Month (1~9, X, Y , Z) Production Year (Lower 2 digits) 8.Type Number The type number of module is specified on the back of module as follows : DMC16105 NY -LY Etching Stamp 9.Applying Precautions Please contact us when questions and/or new problems not specified in this specifications arise.
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 15/16 OPTREX 10.Precautions Relating Product Handling The Following precautions will guide you in handling our product correctly. 1) Liquid crystal display devices ① The liquid crystal display device panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care. ② The polarizer adhering to the surface of the LCD is made of a soft material. Guard against scratching it. 2) Care of the liquid crystal display module against static electricity discharge. ① When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. ② Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. ③ Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity. 3) When the LCD module alone must be stored for long periods of time: ① Protect the modules from high temperature and humidity. ② Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. ③ Protect the modules from excessive external forces. 4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature. 5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity. 7) For models which use CFL: ① High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. ② Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. ③The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life.
DMC16105NY-LY (AD) No.99-0086 OPTREX CORPORATION Page 16/16 OPTREX 8) For models which use touch panels: ①Do not stack up modules since they can be damaged by components on neighboring modules. ②Do not place heavy objects on top of the product. This could cause glass breakage. 9) For models which use COG,TAB,or COF: ①The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. ②Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact. 10) Models which use flexible cable, heat seal, or TAB: ①In order to maintain reliability, do not touch or hold by the connector area. ②Avoid any bending, pulling, or other excessive force, which can result in broken connections. 11.Warranty This product has been manufactured to your company’s specifications as a part for use in your company’s general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. ① We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. ② We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. ③ We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company’s acceptance inspection procedures. ④ When the product is in CFL models, CFL service life and brightness will vary according to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. ⑤ We cannot accept responsibility for industrial property, which may arise through the use of your product, with exception to those issues relating directly to the structure or method of manufacturing of our product. ⑥ Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later.