TG-L1006-0E NOV. 2009K TG-L1006-1E SEP. 2010K GENERAL Developed from the well accepted DIR-500, the RoHS compatible DIR-530 is a panel mount type compact digital tank data indicator. Connecting to any TOKYO KEISO's 2-wire digital tank data transmit- ters as well as tank top type servo operated tank gauges, DIR-530 serves for the following applications. 1. Dedicated receiving instrument for full time monitoring of one tank 2. Inexpensive receiving instrument for moderate size tank farm with a few tanks 3. Interfacing with supervisory system At low cost, DIR-530 constitutes the simple, reliable, accurate digital monitoring and control system of the tank farm in combination with TOKYO KEISO's various tank monitoring 2-wire transmitters.
FEATURES
❏ DIR-530 indicator receives signals from any TOKYO KEISO's 2- wire digital tank data transmitters as well as tank top type servo operated tank gauges. ❏ DIR-530 indicator provides two 4 -20mADC output signals and two alarm relay output signals when it is used as one tank moni- toring. ❏ DIR-530 indicator is able to receive 4 transmitters which have single directional data transmission capability with 2-wire system common to power and signal. ❏ DIR-530 indicator is able to receive 16 transmitters which have bi- directional data transmission capability, i.e. both from indicator to transmitter and vice versa, with 2 independent wirings of power and signal. ❏ DIR-530 indicator is able to be connected to supervisory systems such as personal computer, DCS and sequencer via pre-installed serial and parallel communication ports, RS-232C or RS-485 with Modbus-RTU. ❏ DIR-530 indicator is interchangeable with the current 1 tank re- ceiver i.e. TOKYO KEISO's DIR-200 receiver and DIR-400 re- ceiver, except alarm reset input of DIR-200. It makes your factory renovation much easier. ❏ DIR-530 indicator indicates the operating status of itself as well as level and temperature at the same time. ❏ DIR-530 indicator, its all operation parameters can be set from menu selection through three key switches. ❏ DIR-530 indicator has the compact DIN 96 x 96 mm size to save panel space. DIR-530 DIGITAL TANK DATA INDICATOR
DIR-530 DIGITAL TANK DATA INDICATOR 2T OKYO KEISO CO., LTD. TG-L1006-1E STANDARD SPECIFICATION and OUTLINE OF FUNCTION CONNECTABLE TRANSMITTERS Connectable transmitters Tokyo Keiso's single direction type : DM4-1 Tokyo Keiso's bi-direction type : FW-9000N/DM4-2-1 Number of connectable transmitters Standard : 1 Single direction type : max. 4 Bi-direction type : max.16 Item Specification Including transmission format compatible transmitter Can not be connected at the same time to transmitters with different transmission format. Remark OUTPUT SIGNALS 4-20mA output 1) 2 contacts 2) For output of level and temperature 3) Output range 3.6 to 21.6mA 4) Source standard. Sink is also available. 5) External power supply DC 24V at the time of sink. 6) Load resistance Max. 500Ω. 7) Accuracy : better than /H11006 0.1% (F .S.) 8) Temperature coefficient : less than /H11006 0.01%(F .S.) / °C Relay output for alarm 1) 2 contacts 2) For alarm of level, temperature and transmitter abnormal conditions 3) Contact type : NO, NC (C contact output) 4) Contact capacity : AC125V 0.3A : DC 30V 0.3A Both are load resistance. Item Specification Applicable only when one transmitter is connected. Zero and span can be changed or set freely. Applicable only when one transmitter is connected. Any 2 point alarms are selected freely from 4 level alarms, 2 temperature alarms and transmitter abnormal condition by the setting. Serial output Parallel output 1) Interface : RS-232C signal level or RS-485 2) Protocol Modbus (RTU mode) 3) Baud rate : 2400/4800/9600/19200bps 1) Type 1 or Type 2 2) I/O insulated type by photo coupler To be connected to terminals. Changes of I/O assignment are not allowed. Type 1 : Request is provided, Ready is provided Type 2 : Request is not provided, Ready is provided Remark FUNCTION AND RATING Indication Tank No. : 1 digit Level : 6 digits [mm] : Indicated in 0.1 mm unit for FW-9000 Temperature : 4 digits [°C] in 0.1 unit Status : 2 digits Indicates alarm/error/displacer status of the tank that is currently indicated in symbols. Others : 24 digits LED Indicates operation mode/displacer status/alarm status of the tank that is currently indicated in LED individually. Key operation UP , RIGHT, ENTER total 3 keys, membrane type, 8 mm diameter Item Specification When multiple tanks are connected, automatic scanning is conducted and tank data on indication is updated with every data entry. Alarm setting and alarm determination Displacer control Following alarm points can be set for each tank 4 points of level alarms (HH/H/L/LL) and 2 points of temperature alarms (TH/TL) Remote operation of displacer such as measuring, lifting, stoppage. Alarms are determined by comparing input signals and setting values when signals enter. However, alarm indication is shown only for the selected current tank. Alarm operation is of non-lock type. Applicable only when FW-9000N is connected. Status of displacer is shown on status and LED. Avoid condensation. Metal fitting for panel mounting is attached. Supply voltage AC85 ∼ 250V, 50/60Hz Rated power 20VA at steady state Ambient environment on operation Installation Temperature : 10 to 40°C Humidity : 20 to 80% Panel mount Panel cut 90.5 mm (W) /H11003 90.5 mm (H) with tolerance +1,–0 Except rear terminalOutline dimension 96(W) /H11003 96(H) /H11003 265(D) Painting color Panel : Black Body : SPCC chrome plating Weight Approx. 2kg Accessory Fuse : 1 set (1.0A /H11003 2, 0.5A /H11003 2) Metal fitting for panel installation : 1 set Terminal construction Plug-in screw clamping type terminal Applicable standard RoHS Conformable wire Power supply, grounding : 0.5~2.5mm2 Other signals : 0.5 ∼1.5mm2 Remark OUTLINE DIMENSIONS DIR-530 FRONT VIEW SIDE VIEW PANEL CUT DIMENSION Panel Metal fitting for panel installation REAR VIEW 96.6 96.6 252 30 90.5+1 90.5+1 This drawing shows DIR-532 witch has parallel output connectors behind the body.
TOKYO KEISO CO., LTD. 3TG-L1006-1E DIR-530 DIGITAL TANK DATA INDICATOR NAMES OF PARTS
- FRONT PANEL No. No. C B A PARALLEL HOST MONITOR SERIAL HOST MONITOR TRANSMITTER SCAN MONITOR TEMP . DATA INDICATION LED STATUS DATA INDICATION LED LEVEL DATA INDICATION LED TANK NO. INDICATION LED Description Description ENTER KEY RIGHT KEY UP KEY ALARM MODE LED DISPLACER OPERATION MODE LED DATA SETTING MODE LED Host(S) Up Stop Meas3 Meas2 Meas1 Float Scan Adjust Span Alarm Float Data Mode Host(P) TH TL HH H L LL Alarm 10 9 8 DIR-530 CN1, CN2 F3, 4 F1, 2 PW No. Connector for parallel output I/O terminal for signal line Input terminal for power supply line Fuse for signal line of transmitter Fuse for power supply line Power switch
Description
1 3 5 7 9 111315 17 19 21 23 25 27 29 31 33 2 4 6 8 101214 16 18 20 22 24 26 28 30 32 34 TYPE: DIR-532 TAG No. : MFG. No. : S/N No. : DATE: TOKYO KEISO CO., LTD.
- REAR PANEL (DIR-532) 2 wire single directional digital transmitters (3) Bi-directional transmitters For 16 tanks monitoring (2) Single directional transmitters For 4 tanks monitoring 2 wire bi-directional digital transmitters /H20851DM4-2 (FW-9000 format)/H20852 JB AC supply AC supply DIR-500 mn o C or Parallel output Serial (Modbus) (1) For 1 tank monitoring DC4 - 20mA output (2 points) Alarm output (2 points) (DM4) (FW-9000N) Control RoomField 2 wire digital tank data transmitters Tank Top Type Servo Operated Gauge (DM4-1) AC supply or Parallel output Serial (Modbus) AC supply ... ... Tank Top Type Servo Operated Gauges Tank Top Type Servo Operated Gauges (FW-9000N) Supervisory system HOST COMPUTER DCS PERSONAL COMPUTER Supervisory system HOST COMPUTER DCS PERSONAL COMPUTER Supervisory system HOST COMPUTER DCS PERSONAL COMPUTER Serial (Modbus) or Parallel output DIR-500 mn o C DIR-500 mn o C DIR-500 mn o C Can be connected to 4 transmitters which have the same signal format Can be connected to 16 transmitters which have FW-9000 format APPLICATION EXAMPLES
4T OKYO KEISO CO., LTD. TG-L1006-1E DIR-530 DIGITAL TANK DATA INDICATOR
ORDERING INFORMATION
- MODEL /H17040DIR-531 Parallel output is not provided /H17040DIR-532 Parallel output is provided
- SPECIFICATION 1.Connecting transmitter 1) Connecting transmitter 2) Transmitter format 3) Numbers of connecting transmitters Bi-directional type /L50482FW-9000N /L50482DM4-2 /L50482FW-9000 Single directional type /L50482DM4-1 /L50482FW-9000N /L50482DM /L50482DB-M /L50482DB-ML /L50482DM /L50482Others ( ) Specifications /L50482 Level /L50482 Temperature /L50482 None /L50482 Level /L50482 Temperature /L50482 None /L50482 LL /L50482 L /L50482 H /L50482 HH /L50482 TL /L50482 TH /L50482 ER /L50482 None /L50482 LL /L50482 L /L50482 H /L50482 HH /L50482 TL /L50482 TH /L50482 ER /L50482 None /L50482 Without connection /L50482 With connection Interface /L50482 RS232C /L50482 RS485 Protocol Modbus RTU (Slave) Address ____ Baud rate /L50482 2400 /L50482 4800 /L50482 9600 /L50482 19200 Bit pattern /L50482 N81 /L50482 E81 /L50482 O81 /L50482 Requested /L50482 Not requested Type /L50482 Type 1 ( Request is provided, Ready is provided) /L50482 Type 2 (Request is not provided, Ready is provided) Connector /L50482 CN1 only (Level output only) /L50482 CN1+CN2(Level and Temperature output) Output 1 Output 2 Level setting value Temperature setting value Relay 1 Relay 2 Item 4 to 20mA output Alarm set values when being used as 1 tank monitoring Relay output ✽1, ✽2 Serial output Parallel output Default values at delivery if not specified Level Temperature 0 [mm] 20,000 [mm] 0.0 [°C] 100.0 [°C] 999,999 [mm] 20,000 [mm] 0 [mm] –99,999 [mm] 999,9 [°C] –199,9 [°C] H L RS232C 9600 N81 Type 1 Only CN1 ✽1 : Applicable only when one transmitter is connected. ✽2 : LL.,L,H,HH are used for level alarms. TL, TH for temperature alarms. ER for status alarms. Part name Metal fitting for panel installation Fuses for signal Fuses for power source Serial communication cable Parallel communication cable-1 Parallel communication cable-2 Terminal block for parallel communication Part No. DIR530-MF DIR530-FS05 DIR530-FS20 DIR530-SCB-/L50482m DIR530-PCB1-/L50482m DIR530-PCB2-/L50482m DIR530-PTB Remark 1 unit 0.5A 2 pieces 2.0A 2 pieces D-Sub 9pin connector with a connector at one end with two connectors at both ends For cable with connectors at both ends Head Office : Shiba Toho Building, 1 – 7 – 24 Shibakoen, Minato-ku, Tokyo 105 – 8558 Tel : +81-3 – 3431 – 1625 (KEY) ; Fax : +81-3 – 3433 – 4922 * Specification is subject to change without notice. 2.Output OPTION