DGP30E48S5 POWER-ONE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

DESCRIPTION

The single output DGP30 Series is designed to accept an extended 2:1 input voltage range for use in industrial and telecom applications. The output of the converter is electrically isolated, thereby allowing the output to be configured as a positive or negative output voltage. For additional system utility output Trim and Remote ON/OFF are featured. Overcurrent protection, overtemperature protection, and output overvoltage transient protection allow safe, reliable operation.

FEATURES

  • Remote ON/OFF and TRIM
  • Low OFF Current
  • Overcurrent and Overtemperature Protection
  • Efficiencies to 86%
  • Transient Output Overvoltage Protection
  • 1544V Isolation
  • Five-Side Shielded Case
  • Extended Range Input (2:1) DGP30 SERIES SINGLE OUTPUT Mechanical tolerances unless otherwise noted: X.XX dimensions: ±0.020 inches X.XXX dimensions: ±0.005 inches NOTES (1) All parameters measured at Tc = 25°C, nominal input voltage and full rated load unless otherwise noted. Refer to the Technical Reference Section for the definition of terms, measurement circuits and other information. (2) ON/OFF pin is referenced to pin 2, -Input. See DGP30 Series Application Notes for the specific requirements of this feature. (3) The Case is electrically connected to Pin 1, +Input. (4) Full output trim range may not be available at minimum input voltage and full load. Full trim is guaranteed from minimum input voltage, plus 5%, and full load. (5) The case thermal impedance is specified as the case temperature rise over ambient per package watt dissipated. BOTTOM VIEW SIDE VIEW 0.000 0.000 0.3 0.000 2.02 (51.31) (7.62) 0.040 (1.02) DIA

6 PLACES

0.55 1.62 (13.97) (41.15)2 3 7 51.800 0.11 0.700 0.400 0.100 0.600 0.300 0.31 (10.16) (2.54) (7.62) (7.9) (17.78) (15.24) (2.8) (45.72) Rev. 04/2000

DGP30 SERIES – SINGLE OUTPUT NOTES (1) All parameters measured at Tc=25 ° C case temperature, nominal input voltage and full rated load unless otherwise noted. Refer to the Technical Reference Section for definition of terms, measurement circuits and other information. (2) Minimum load required for rated regulation only. Module will not be damaged if run at less than minimum load. (3) Short term stability is specified after a 30 minute warm-up at full load, and with constant line, load and ambient conditions. (4) The input ripple rejection is specified for DC to 120Hz ripple with a modulation amplitude of 1% Vin. (5) Noise is measured per Technical Reference Section. Output noise is measured with a 1µF tantalum capacitor connected 1” from the output pins. www.power-one.comwww.power-one.com For the Most Up-To-Date Information

24 Hours/Day—7 Days/Week

NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems , equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. Specifications are subject to change without notice.

DGP30 SERIES – SINGLE OUTPUT DGP30 SERIES BLOCK DIAGRAM 5 + OUTPUT SHIELDED ISOLATION TRANSFORMER

7 TRIM

REFERENCESIX SIDED SHIELDED COPPER CASE 2– INPUT ON/OFF ON/OFF C D 5 270 /H9262F6 . 8 V 12 40 /H9262F 15V 15 40 /H9262F 18V + INPUT CURRENT MODE PWM THERMAL SHUTDOWN DC - OUT 40 45 50 55 60 OUTPUT POWER DERATING AMBIENT TEMPERATURE POWER OUTPUT 35 65 100% LOAD 50% LOAD 45 75 EFFICIENCY Vs. LINE INPUT VOLTAGE LINE INPUT (VOLTS) EFFICIENCY (%) 08 0 905020 30 40 60 7010 100 EFFICIENCY Vs. LOAD LOAD (%) EFFICIENCY (%) 1.2 100% LOAD 75% LOAD 50% LOAD 0.7 0.2 0.3 0.4 0.5 0.6 0.8 0.9 1.0 1.1 30 70 40 50 60 80 INPUT RIPPLE Vs. LINE INPUT VOLTAGE LINE INPUT (VOLTS) INPUT RIPPLE (RMS) 1.4 100% LOAD 50% LOAD 0.0 0.4 0.2 0.6 0.8 1.0 1.2 07 0 10 20 30 40 50 60 80 INPUT CURRENT Vs. LINE INPUT VOLTAGE LINE INPUT (VOLTS) INPUT CURRENT (AMPS) 120 100 110 0 18020 40 60 80 100 120 140 160 200 OUTPUT VOLTAGE Vs. OUTPUT LOAD OUTPUT LOAD (%) OUTPUT VOLTAGE (%) Typical Performance: (Tc=25°C, Vin=Nom VDC, Rated Load) www.power-one.comwww.power-one.com For the Most Up-To-Date Information