Power entry modules without line filter DF11https://www.schurter.com /PG05 Connectors IEC Appliance Inlet C14 or C18 with recessed Circuit Breaker TA45 Approvals and Compliances C14 70° C C18 70° C

Description

  • Panel Mount : Screw-on version from front or rear side, snap-in version from front side - 2 Functions : Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired - Circuit Breaker non-illuminated or illuminated - Suitable for use in equipment according to IEC/UL 60950 Other versions on request - Unwired versions - Other rocker marking - Variant with notch for V-Lock mating Cordsets References Alternative: version with line filter DF12 Substitute for type 6145 Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product, Microsite Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC 10 A / 250 VAC; 50 Hz Ratings UL/CSA 1 - 15 A / 250 VAC; 60 Hz Dielectric Strength > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) Allowable Operation Tempe- rature -10 °C to 55 °C IP-Protection from front side IP 40 acc. to IEC 60529 Insulation cover Suitable for appliances with protection class I or II acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.5/2/2.5/3 mm Material: Housing Thermoplastic, black, UL 94V-0 appliance inlet/-outlet C14 / C18 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or non- illuminated. Optional with undervoltage- or remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In ≥ 3A/240VAC : 300A Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals

Power entry modules without line filterDF11 https://www.schurter.com /PG05 Connectors Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DF11 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40011305 UL Approvals UL UL File Number: E96454 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. MicrositeV-Lock SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

Power entry modules without line filter DF11https://www.schurter.com /PG05 Connectors Dimensions [mm] Screw-on Version R 2.8 R4.7 28.2 29 R 2.55 ø 3.6/M3 R 2.95 4.5 82.5 73.5 ±0.10±0.05 ±0.10 ±0.05 ±0.10 76.7 9.7 37.1 91.5 82.5 32.5 28.7 9.15 73.2 4.5 Ø 3.3 Ø 6.4 2.3 41.710.6 4.827.9 0.8 9.4 9.45 72.7 Snap-in version R 2.8 R4.7 28.2 29 R 2.55 R 2.95 73.5 ±0.10 ±0.05 ±0.10 76.7 9.7 37.1 32.5 28.7 1.9 73.2 2.3 41.710.6 4.827.9 S ±0.1 2.15 9.45 72.7 * --- Version TA45 with undervoltage release

Power entry modules without line filterDF11 https://www.schurter.com /PG05 Connectors Diagrams 1) 2) L' P1 N' P2 N L PE PE' 1) Line 2) Load

Power entry modules without line filter DF11https://www.schurter.com /PG05 Connectors ABT W F 150 C0 Colours Switch front Rocker W black white – B black black – 6 black – orange transp. F embossed / Relief H printed / bedruckt white / weiss K printed / bedruckt black / schwarz L printed / bedruckt white / weiss Surface Illustration Colour of print Rocker legend l O ON OFF ON OFF l O M printed black P printed white R printed black Surface Illustration Colour of print Rated current circuit breaker of equipment Without release: code C0 Undervoltage release Remote trip release UE ZA Code Rated voltage Un

  • • •
  • • •
  • • •

240 V AC

230 V AC

120 V AC

l O OI OI Position of the r ocker legend e.g F In Code 0,1 J01 0,2 J02 0,3 J03 0,4 J04 0,5 J05 0,6 J06 0,7 J07 0,8 J08 0,9 J09 1,0 J10 1,1 J11 1,2 J12 In Code 1,3 J13 1,4 J14 1,5 J15 1,6 J16 1,7 J17 1,8 J18 1,9 J19 2,0 J20 2,1 J21 2,2 J22 2,3 J23 2,5 J25 In Code 2,8 J28 3,0 030 3,5 035 4,0 040 4,5 045 5,0 050 6,0 060 6,5 065 7,0 070 7,5 075 8,0 080 9,0 090 In Code 10,0 100 11,0 110 12,0 120 13,0 130 14,0 140 15,0 150 20,0 200 Table 1 Selection for type T A45 Order example

  • Circuit Breaker of Equipment
  • 2-pole, rocker actuated
  • Quick connect terminal Other types on r equest Without illumination With illumination 220…240 V 110…120 V Diagram Thermal overload pr otection 1-pole 2-pole ABT ABD A12 A32 A14 A34 P2 P1 P2 P1 P2 P1 P2 P1b P2 P1b a P2 P1c

Power entry modules without line filterDF11 https://www.schurter.com /PG05 Connectors Technical data (continued) Circuit breaker Tripping characteristics In < 3 A Tripping characteristics Effect of ambient temperatur e 1) The unit is calibrated for an ambient temperatur e of +23 °C. To deter mine the rated curr ent for a lower or higher ambient tempera- ture, use a correction factor fr om the table below. * Ambient temperatur e [°C] Correction factor –10 0,89 – 5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 * Temperature must be measur ed at the rear of the breaker next to the terminals after equipment operating temperatur e has been reached. Optional Variants 0 standard

9 V-Lock

0 Screw mounting

1 Snap-in mounting s = 1.0 mm 2 Snap-in mounting s = 1.5 mm 3 Snap-in mounting s = 2.0 mm 4 Snap-in mounting s = 2.5 mm 5 Snap-in mounting s = 3.0 mm Terminal PE 0 without terminal (PCII) 1 Quick-connect terminal 6.3x0.8 mm Terminal N 1 Quick-connect terminals 6.3x0.8mm, without connection to T A45 3 connection to TA45 non insulated Terminal L 1 Quick-connect terminals 6.3x0.8mm, without connection to T A45 3 connection to TA45 non insulated 1) Example Rated current at +23 °C 6,0 A Ambient temperatur e +40 °C Correction factor 1,08 Chosen rated curr ent at + 40 °C ambient temperatur e 6 A x 1,08 = 6,5 A 10’000 2000 1000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 Multiple of rated current [ x In ] 10854321,32 Tripping time Type TA45 Rated current In < 3 A 1-pole protected 2-pole protected Ambient temp. +23 °C 10’000 2’000 1’000 500 200 100 0,5 0,3 0,2 0,1 [ sec ][ min ] 1,05 [ x In ] 10854321,32 Type TA45 Rated current I > 3... < 15 A 1-pole protected 2-pole protected Ambient temp. +23 °C Multiple of rated current Tripping time n Configuratorcode (example) DF11 - ABTWF150C0 - 000 - 111 - 009 Order code TA 45 (2-pole rocker-switch without accessories) Type see table 1

Power entry modules without line filter DF11https://www.schurter.com /PG05 Connectors Packaging unit 20 Pcs Accessories Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to DF11 Connector Overview complete

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782

4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to DF11 ... Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS Power Cord further types to DF11 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 01.12.2017