DEA162690LT-5051B1 TDK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 6

Technical content

Multilayer Low Pass Filter For 673-2690MHz DEA162690LT-5051B1 1.6x0.8mm [EIA 0603]* * Dimensions Code JIS[EIA] RF Components

  • All specifications are subject to change without notice.  Before using these products, be sure to request the delivery specifications. 20180918 / rf_lpf_dea162690lt-5051b1_en.fm Multilayer Low Pass Filter For 673-2690MHz SHAPES AND DIMENSIONS RECOMMENDED LAND PATTERN EVALUATION BOARD DEA162690LT-5051B1 Conformity to RoHS Directive 0.30±0.050.40±0.05 Dimensions in mm (3) (2) (4) (1) 0.60±0.101.60±0.10 0.80±0.10 Marking [Top view] [Bottom view] 0.225±0.05 0.65±0.05 0.22±0.050.21±0.05

1 In/Out Port

2 GND

3 Out/In Port

4 GND

(3) (4) (2) (1) 0.275 0.450 0.700 0.210 Dimensions in mm 0.245 0.250 Line width should be designed to match 50Ω characteristic impedance, depending on PCB material and thickness. Thru hole Resist Surface Pattern Material, Layer Top Resist Copper Surface Pattern FR-4 Copper Inner GND FR-4 Copper Bottom GND Thickness Resist 0.035mm 0.10mm 0.018mm 0.30mm 0.035mm RoHS Directive Compliant Product: See the following for more details.https://product.tdk.com/info/en/environment/rohs/index.html

 All specifications are subject to change without notice.  Before using these products, be sure to request the delivery specifications. 20180918 / rf_lpf_dea162690lt-5051b1_en.fm DEA162690LT -5051B1

ELECTRICAL CHARACTERISTICS

ɾTa: +25±5°C TEMPERATURE RANGE Item Frequency Range (MHz) Min. Typ. Max. Insertion Loss (dB) 673 to 2690 — 0.37 0.50 673 to 2690 — — 0.60 (–40 to +85°C) Ripple (dB) (Over any 200 MHz range) 673 to 2690 — 0.07 0.20 Group Delay Ripple (ns) (Over any 20 MHz range) 673 to 2690 — 0.01 — Return Loss (dB) 673 to 2690 9.54 14.3 — Attenuation (dB) 4950 to 6000 35 42.3 — 6000 to 12750 45 49.0 — Power Handling (dBm) — — 35 Characteristic Impedance () 50 (Nominal) Operating temperature Storage temperature ʢ°Cʣ ʢ°Cʣ –40 to +85 –40 to +85

 All specifications are subject to change without notice.  Before using these products, be sure to request the delivery specifications. 20180918 / rf_lpf_dea162690lt-5051b1_en.fm DEA162690LT -5051B1 FREQUENCY CHARACTERISTICS INSERTION LOSS ATTENUATION RETURN LOSS 40003500 Frequency(MHz) 500 1000 20001500 30002500 3.0 0.5 1.0 2.0 2.5 1.5 0.0 Insertion Loss(dB) 140002000 Frequency(MHz) 0 4000 6000 10000 12000 8000 Attenuation(dB) Return Loss(dB) 40003500 Frequency(MHz) 500 1000 20001500 30002500

 All specifications are subject to change without notice.  Before using these products, be sure to request the delivery specifications. 20180918 / rf_lpf_dea162690lt-5051b1_en.fm DEA162690LT -5051B1 RECOMMENDED REFLOW PROFILE t3 : Time within 5°C of actual peak temperature The maximum number of reflow is 3. Preheating Soldering Critical zone (T3 to T4) Peak Temp. Time Temp. Time Temp. Time T1 T2 t1 T3 t2 T4 t3 150°C 200°C 60 to 120sec 217°C 60 to 120sec 240 to 260°C 30sec max. Preheating Soldering T3 T3 t: Time T: Temperature Peak 6°C/sec or lower 3°C/sec or lower

 All specifications are subject to change without notice.  Before using these products, be sure to request the delivery specifications. 20180918 / rf_lpf_dea162690lt-5051b1_en.fm REMINDERS FOR USING THESE PRODUCTS Before using these products, be sure to request the delivery specifications. SAFETY REMINDERS Please pay sufficient attention to the warnings for safe designing when using these products. The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equi pment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment, industrial robots) under a normal operation and use condition. The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society, person or property. Please understand that we are not responsible for any damage or liability caused by use of the products in any of the applicati ons below or for any other use exceeding the range or conditions set forth in this catalog. (1) Aerospace/Aviation equipment (2) Transportation equipment (cars, electric trains, ships, etc.) (3) Medical equipment (4) Power-generation control equipment (5) Atomic energy-related equipment (6) Seabed equipment (7) Transportation control equipment (8) Public information-processing equipment (9) Military equipment (10) Electric heating apparatus, burning equipment (11) Disaster prevention/crime prevention equipment (12) Safety equipment (13) Other applications that are not considered general-purpose

applications

When using this product in general-purpose applications, you are kindly requested to take into consideration securing protection circuit/ equipment or providing backup circuits, etc., to ensure higher safety. REMINDERS