Multilayer Band Pass Filter For 2400-2500MHz DEA162450BT-1288B1 1.6x0.8mm [EIA 0603]* * Dimensions Code JIS[EIA] RF Components
- All specifications are subject to change without notice.
- Before using these products, be sure to request the delivery specifications. 20150601 / rf_bpf_dea162450bt-1288b1_en.fm20150601 / rf_bpf_dea162450bt-1288b1_en.fm Multilayer Band Pass Filter For 2400-2500MHz SHAPES AND DIMENSIONS RECOMMENDED LAND PATTERN DEA162450BT-1288B1 Conformity to RoHS Directive Dimensions in mm 1 IN
2 GND
3 OUT
(2)( 3)(1) 0.70max.1.60±0.15 0.80±0.10 Marking [Top view] [Bottom view] 0.50±0.10 0.60±0.10 Dimensions in mm0.25 0.25 0.245 0.50 0.21 0.70 RoHS Directive Compliant Product: See the following for more details related to RoHS Directive compliant products. http://product.tdk.com/en/environment/rohs/
- All specifications are subject to change without notice.
- Before using these products, be sure to request the delivery specifications. 20150601 / rf_bpf_dea162450bt-1288b1_en.fm20150601 / rf_bpf_dea162450bt-1288b1_en.fm DEA162450BT -1288B1
ELECTRICAL CHARACTERISTICS
ɾTa: +25±5°C TEMPERATURE RANGE Item Frequency Range (MHz) Min. Typ. Max. Insertion Loss (dB) 2400 to 2500 — 1.03 1.3 2400 to 2500 — — 1.6 (–40 to +85°C) Return Loss (dB) 2400 to 2500 10 19.9 — Attenuation (dB) 800 25 26 — 3200 17 19 — 4800 to 5000 20 40 — 7200 to 7500 20 25 — Characteristic Impedance (/g58) 50 (Nominal) Operating temperature Storage temperature ʢ°Cʣ ʢ°Cʣ –40 to +85 –40 to +85
- All specifications are subject to change without notice.
- Before using these products, be sure to request the delivery specifications. 20150601 / rf_bpf_dea162450bt-1288b1_en.fm20150601 / rf_bpf_dea162450bt-1288b1_en.fm DEA162450BT -1288B1 FREQUENCY CHARACTERISTICS INSERTION LOSS ATTENUATION RETURN LOSS 2200 2700 2300 2400 2500 2600 Frequency(MHz) 3.0 1.0 1.5 2.0 2.5 0.5 0.0 Insertion Loss(dB) 500 75001500 2500 3500 4500 5500 6500 Attenuation(dB) Frequency(MHz) 2200 2700 2300 2400 2500 2600 Frequency(MHz) Return Loss(dB)
- All specifications are subject to change without notice.
- Before using these products, be sure to request the delivery specifications. 20150601 / rf_bpf_dea162450bt-1288b1_en.fm20150601 / rf_bpf_dea162450bt-1288b1_en.fm DEA162450BT -1288B1 RECOMMENDED REFLOW PROFILE Soaking Working Soldering Peak Temp. Time Temp. Time Temp. Time Temp. T1 T2 t1 T3 t2 T4 t3 T5 150°C 180°C 60 to 120s 230°C more than 30s 247 to 253°C within 10s 260°C max. Soaking Working T3 T3 T4T4 T5 t: Time Soldering T: Temperature Peak
- All specifications are subject to change without notice.
- Before using these products, be sure to request the delivery specifications. 20150601 / rf_bpf_dea162450bt-1288b1_en.fm20150601 / rf_bpf_dea162450bt-1288b1_en.fm REMINDERS FOR USING THESE PRODUCTS Before using these products, be sure to request the delivery specifications. SAFETY REMINDERS Please pay sufficient attention to the warnings for safe designing when using these products. The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equi pment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment, industrial robots) under a normal operation and use condition. The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society, person or property. Please understand that we are not responsible for any damage or liability caused by use of the products in any of the applicati ons below or for any other use exceeding the range or conditions set forth in this catalog. (1) Aerospace/Aviation equipment (2) Transportation equipment (cars, electric trains, ships, etc.) (3) Medical equipment (4) Power-generation control equipment (5) Atomic energy-related equipment (6) Seabed equipment (7) Transportation control equipment (8) Public information-processing equipment (9) Military equipment (10) Electric heating apparatus, burning equipment (11) Disaster prevention/crime prevention equipment (12) Safety equipment (13) Other applications that are not considered general-purpose
applications
When using this product in general-purpose applications, you are kindly requested to take into consideration securing protectio n circuit/ equipment or providing backup circuits, etc., to ensure higher safety. REMINDERS