Doc #97035 DATA DELAY DEVICES, INC. 12/10/97 3 Mt. Prospect Ave. Clifton, NJ 07013 5-TAP, ECL-INTERFACED FIXED DELAY LINE (SERIES DDU11H)
FEATURES
Five equally spaced outputs Fits standard 16-pin DIP socket Auto-insertable Input & outputs fully 10KH-ECL interfaced & buffered FUNCTIONAL DESCRIPTION The DDU11H-series device is a 5-tap digitally buffered delay line. The signal input (IN) is reproduced at the outputs (T1-T5), shifted in time by an amount determined by the device dash number (See Table). For dash numbers less than 10, the total delay of the line is measured from T1 to T5. The nominal tap-to-tap delay increment is given by one-fourth of the total delay, and the inherent delay from IN to T1 is nominally 1.5ns. For dash numbers greater than or equal to 10, the total delay of the line is measured from IN to T5. The nominal tap-to-tap delay increment is given by one-fifth of this number. SERIES SPECIFICATIONS Minimum input pulse width: 20% of total delay Output rise time: 2ns typical Supply voltage: -5VDC ± 5% Power dissipation: 200mw typical (no load) Operating temperature: -30° to 85° C Temp. coefficient of total delay: 100 PPM/°C 25% 25% 25% 25% VCC GND IN Functional diagram for dash numbers < 10 1.5ns 20% 20% 20% 20% 20% VCC GND IN Functional diagram for dash numbers >= 10 1997 Data Delay Devices data delay devices, inc. GND N/C IN N/C N/C VEE GND N/C N/C N/C N/C GND IN VEE GND DDU11H-xx DIP DDU11H-xxM Military DIP DDU11H-xxC3 SMD DDU11H-xxMC3 Mil SMD PIN DESCRIPTIONS IN Signal Input T1-T5 Tap Outputs VEE -5 Volts GND Ground DASH NUMBER SPECIFICATIONS Part Number Total Delay (ns) Delay Per Tap (ns) DDU11H-4 2 ± 1.0 * 0.5 ± 0.3 DDU11H-5 4 ± 1.0 * 1.0 ± 0.3 DDU11H-8 6 ± 2.0 * 1.5 ± 0.4 DDU11H-10 10 ± 2.0 2.0 ± 0.4 DDU11H-20 20 ± 3.0 5.0 ± 1.0 DDU11H-25 25 ± 3.0 5.0 ± 2.0 DDU11H-50 50 ± 3.0 10.0 ± 2.0 DDU11H-75 75 ± 4.0 15.0 ± 2.0 DDU11H-100 100 ± 5.0 20.0 ± 2.0 DDU11H-150 150 ± 7.5 30.0 ± 2.0 DDU11H-200 200 ± 10.0 40.0 ± 2.0 DDU11H-250 250 ± 12.5 50.0 ± 2.5 DDU11H-300 300 ± 15.0 60.0 ± 3.0 DDU11H-400 400 ± 20.0 80.0 ± 4.0 DDU11H-500 500 ± 25.0 100.0 ± 5.0 * Total delay is referenced to first tap output Input to first tap = 1.5ns ±± 1ns NOTE: Any dash number between 4 and 500 not shown is also available.
Doc #97035 DATA DELAY DEVICES, INC. 12/10/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com APPLICATION NOTES HIGH FREQUENCY RESPONSE The DDU11H tolerances are guaranteed for input pulse widths and periods greater than those specified in the test conditions. Although the device will function properly for pulse widths as small as 20% of the total delay and periods as small as 40% of the total delay (for a symmetric input), the delays may deviate from their values at low frequency. However, for a given input condition, the deviation will be repeatable from pulse to pulse. Contact technical support at Data Delay Devices if your application requires device testing at a specific input condition. POWER SUPPLY BYPASSING The DDU11H relies on a stable power supply to produce repeatable delays within the stated tolerances. A 0.1uf capacitor from VEE to GND, located as close as possible to the VEE pin, is recommended. A wide VEE trace and a clean ground plane should be used. DEVICE SPECIFICATIONS TABLE 1: ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL MIN MAX UNITS NOTES DC Supply Voltage VEE -7.0 0.3 V Input Pin Voltage VIN VEE - 0.3 0.3 V Storage Temperature TSTRG -55 150 C Lead Temperature TLEAD 300 C 10 sec TABLE 2: DC ELECTRICAL CHARACTERISTICS (0C to 75C) PARAMETER SYMBOL MIN TYP MAX UNITS NOTES High Level Output Voltage VOH -1.020 -0.735 V VIH = MAX,50Ω to -2V Low Level Output Voltage VOL -1.950 -1.600 V VIL = MIN, 50Ω to -2V High Level Input Voltage VIH -1.070 V Low Level Input Voltage VIL -1.480 V High Level Input Current IIH 475 µA VIH = MAX Low Level Input Current IIL 0.5 µA VIL = MIN
Doc #97035 DATA DELAY DEVICES, INC. 12/10/97 3 Mt. Prospect Ave. Clifton, NJ 07013 PACKAGE DIMENSIONS DDU11H-xx (Commercial DIP) DDU11H-xxM (Military DIP) .150 ±.030 .800 TYP. .320 MAX. .018 TYP. .400 TYP. .300 TYP. .010 TYP. .700 TYP. .020 TYP. .100 TYP. DDU11H-xxC3 (Commercial SMD) DDU11H-xxMC3 (Military SMD) .880±.020 .882 ±.005 .020 TYP. .040 TYP. .100 .090 .700 .280 MAX. .590 MAX. .010±.002 .050 ±.010 .710 ±.005 .007 ±.005
Doc #97035 DATA DELAY DEVICES, INC. 12/10/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com DELAY LINE AUTOMATED TESTING TEST CONDITIONS INPUT: OUTPUT: Ambient Temperature: 25oC ± 3oC Load: 50Ω to -2V Supply Voltage (Vcc): -5.0V ± 0.1V Cload: 5pf ± 10% Input Pulse: Standard 10KH ECL Threshold: (VOH + VOL) / 2 levels (Rising & Falling) Source Impedance: 50Ω Max. Rise/Fall Time: 2.0 ns Max. (measured between 20% and 80%) Pulse Width: PWIN = 1.5 x Total Delay Period: PERIN = 10 x Total Delay NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. OUT TRIG IN REF TRIG Test Setup DEVICE UNDER TEST (DUT) OSCILLOSCOPE PULSE GENERATOR IN Timing Diagram For Testing TRISE TFALL PERIN PWIN TRISE TFALL 20% 20% 50% 50% 80% 80% 50% 50% VIH VIL VOH VOL INPUT SIGNAL OUTPUT SIGNAL