DD22_17 SCHURTER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
Power Entry Modules with Line Filter DD22https://www.schurter.com /PG06 EMC Products IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole, for PCB Mounting Order required accessories separately Approvals and Compliances C14 70° C
Description
- Panel Mount : Screw-on mounting on PCB , from rear-side - 4 Functions : Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for fuse-links 5 x 20 mm 1- or 2-pole , Line filter in standard and medical version - V-Lock notch standard - PCB terminals Unique Selling Proposition - Most compact power entry module - Attractive flat design - Switch for highest inrush current - V-Lock cord retaining Characteristics - Ultra-compact design. Ideal for low profile designs - All single elements are already wired - For added safety "Extra-Safe" fuse drawers are available - Ideal for application with high transient loads - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Fuse drawer 1-pole, plus spare fuse case - Fuse drawer 2-pole, with shorting bar - Other rocker marking - Line switch, illuminated - Line switch 1-pole - Medical version M80 - Protection class II, 70°C References Alternative: version without line filter DD21 Alternative: Standard version Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor- Stock-Check, Accessories, Detailed request for product, Microsite Technical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 250 VAC; 50/60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (1 min/50 Hz) Allowable Operation Tempe- rature -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 IP-Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Terminal For PCB mounting 3 mm additional quick connect 6.3 x 0.8 mm Panel Thickness S Screw-on mounting: max 3 mm Mounting screw torque max 0.5 Nm Material: Housing Thermoplastic, black, UL 94V-0 appliance inlet/-outlet C14 acc. to IEC 60320-1 UL 498 CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Fuseholder 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Power Acceptance @ Ta > 23°C Admissible power acceptance at higher ambient temperature see derating cur- ves Line Switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Line Filter Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details MTBF > 2'000'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals
Power Entry Modules with Line FilterDD22 https://www.schurter.com /PG06 EMC Products Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DD22 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40001522 UL Approvals UL UL File Number: E72928 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the en- hanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. MicrositeV-Lock SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1
Power Entry Modules with Line Filter DD22https://www.schurter.com /PG06 EMC Products Dimension [mm] Screw version 49.2 29.72.15 3.4 11.55 R 4.35 3.55 11.5 14.75 58.5 66.3 4.5 17 ±0.10 2.8 47.69.8 3.5 0.85 30.8 16.25 30.1 58.5 49.6 ±0.15 ±0.10 R 4.5 ±0.05 3.6 60.931.5 57.5 6.2 ±0.2030.8 3.6 6.641 3.4 1.6 1.6+0.10 57.5 +0.10 ±0.2 R 4.4 1.6+0.10 3.6 11.5 ±0.15 14.75±0.15 ±0.16.05 3.55 ±0.1 1) all terminals with 1.25 x 0.8 2) Quick connect terminal 6.3 x 0.8 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 10 100 2.2 1 2 Standard Version 2 x 4 100 2.2 1 4 Standard Version 2 x 1.5 100 2.2 1 6 Standard Version 2 x 0.8 100 2.2 1 10 Standard Version 2 x 0.3 100 2.2 1
1 Medical Version (M5) 2 x 10 100 - 1
2 Medical Version (M5) 2 x 4 100 - 1
4 Medical Version (M5) 2 x 1.5 100 - 1 6 Medical Version (M5) 2 x 0.8 100 - 1 10 Medical Version (M5) 2 x 0.3 100 - 1
Power Entry Modules with Line FilterDD22 https://www.schurter.com /PG06 EMC Products Diagrams Filter Standard non-illuminated L PE N Cx Cy Cy PE’ R 1) 2)F1 PE” S 1) Line 2) Load Filter Medical M5 non-illuminated L PE N Cx L2 Cy PE’ RS 1) 2)F1 PE” 1) Line 2) Load Derating Curves 1-pole Admissible power acceptance in Watt02 04 06 08 0 100 I = << In I = 0.7 In I = 1.0 In 2.0 1.5 1.0 0.5 0.0 Ambient air temperature Ta °C 2-pole Admissible power acceptance in Watt 02 04 06 08 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.6 0.6 0.4 0.8 1.2 1.0 1.4 Ambient air temperature Ta °C Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version 1 A 2 A 4 A 6 A 10 A
Power Entry Modules with Line Filter DD22https://www.schurter.com /PG06 EMC Products Medical version (M5) 1 A 2 A 4 A 6 A 10 A All Variants Rated Current [A] Filter-Type Fuseholder Line Switch Illumination Order Number 1 Standard Version 1-pole 2-pole non-illuminated DD22.1111.1111 █ 2 Standard Version 1-pole 2-pole non-illuminated DD22.2111.1111 4 Standard Version 1-pole 2-pole non-illuminated DD22.4111.1111 6 Standard Version 1-pole 2-pole non-illuminated DD22.6111.1111 10 Standard Version 1-pole 2-pole non-illuminated DD22.9111.1111 1 Standard Version 2-pole 2-pole non-illuminated DD22.1121.1111 2 Standard Version 2-pole 2-pole non-illuminated DD22.2121.1111 █ 4 Standard Version 2-pole 2-pole non-illuminated DD22.4121.1111 6 Standard Version 2-pole 2-pole non-illuminated DD22.6121.1111 10 Standard Version 2-pole 2-pole non-illuminated DD22.9121.1111 █ 1 Medical Version (M5) 2-pole 2-pole non-illuminated DD22.1321.1111 2 Medical Version (M5) 2-pole 2-pole non-illuminated DD22.2321.1111 4 Medical Version (M5) 2-pole 2-pole non-illuminated DD22.4321.1111 █ 6 Medical Version (M5) 2-pole 2-pole non-illuminated DD22.6321.1111 10 Medical Version (M5) 2-pole 2-pole non-illuminated DD22.9321.1111 █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 20 Pcs Required Accessory Fusedrawer für Fuse Links 5x20 mm, with or without Voltage Selector Insert Fingergrip, 2-pole 4301.1401 Extra-Safe, 2-pole 4301.1403 Fingergrip, 1-pole 4301.1405 Extra-Safe, 1-pole 4301.1407 ...
Power Entry Modules with Line FilterDD22 https://www.schurter.com /PG06 EMC Products Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to DD22 Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to DD22 ... Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS Power Cord further types to DD22 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 02.12.2017