DD14_V01 SCHURTER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Power Entry Modules with Line Filter DD14https://www.schurter.com /PG06 EMC Products IEC Appliance Inlet C14 with Filter 2-Stages, Fuseholder 1- or 2-pole, Line Switch 2-pole Screw-on mounting horizontal (version B) Screw-on mounting vertical (version A) Snap-in mounting See below: Approvals and Compliances C14 70° C
Description
- Panel mount : Snap-in or screw-on mounting front side - 4 Functions : Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for fuse-links 5 x 20 mm 1- or 2-pole , 2-Stages line filter in standard and medical version - V-Lock notch standard - Quick connect terminals 6.3 x 0.8 mm Unique Selling Proposition - Most compact power entry module with 2-stages filter - Attractive flat design - Various mounting options - V-Lock cord retaining Characteristics - Ultra-compact design. Ideal for low profile designs Aluminum case provides good shielding - All single elements are already wired - Ideal for application with high transient loads - Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP , 1 MOPP) For applications according IEC/UL 62368-1 we recommend variants with bleed resistor Other versions on request - Solder terminals - Fuse drawer 1-pole, plus spare fuse case - Fuse drawer 2-pole, with shorting bar - Other rocker marking - Line switch, illuminated - Line switch 1-pole - Medical Version (M80) - Class X1- and Y1-capacitors for enhanced withstand voltage References Alternative: version without line filter DD11 Alternative: version with 1-stage filter DD12 Weblinks pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 8 A @ Ta 40 °C / 250 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) Allowable Operation Tempe- rature -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 IP-Protection front side IP40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class I acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw-on mounting: max 8 mm Mounting screw torque max 0.5 Nm Snap-in version: 1 mm - 3 mm Material: Housing Thermoplastic, black, UL 94V-0 Appliance inlet/-outlet C14 acc. to IEC 60320-1 UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Fuseholder 1-/2-pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Power Acceptance @ Ta > 23°C Admissible power acceptance at higher ambient temperature see derating cur- ves Line Switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Line Filter Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details MTBF > 2'000'000 h acc. to MIL-HB-217 F Approvals and Compliances
Power Entry Modules with Line FilterDD14 https://www.schurter.com /PG06 EMC Products Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree- ments by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DD14 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40001522 UL Approvals UL UL File Number: E72928 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 62368-1 Audio/video, information and communication technology equipment - Part 1: Safety requirements Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 & -13.
Power Entry Modules with Line Filter DD14https://www.schurter.com /PG06 EMC Products Compliances The product complies with following Guide Lines Identification Details Initiator Description RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. White Paper Glow wire test SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP , 1 MOPP) Dimension [mm] Screw version A 15.1 1.3 31.5 9.8 60 5.9 3.4 56 ±0.15 ±0.10 ±0.10 ±0.5 29.8 R 3.5 3.4/M3 49.3 90° N PE L 3.25
Power Entry Modules with Line FilterDD14 https://www.schurter.com /PG06 EMC Products Screw version B N PE L 49.3 ±0.10 29.8 ±0.10 R 3.5 3.4/M3 ±0.5 9.8 1.315.1 3.4 5.9 90° ±0.15 3.25 Snap-in mounting from front side 49.3 61.51.315.1 32.5 9.8 4.4 29.5 R 3.5 ±0.10 ±0.10 ±0.5 N PE L
Power Entry Modules with Line Filter DD14https://www.schurter.com /PG06 EMC Products Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacity Cy1 [nF] Capacity Cy2 [nF] R [MΩ] 1 Standard version 2 x 10 220 1.5 1 1 2 Standard version 2 x 4 220 1.5 1 1 4 Standard version 2 x 1.5 220 1.5 1 1 6 Standard version 2 x 0.8 220 1.5 1 1 8 Standard version 2 x 0.6 220 1.5 1 1 10 Standard version 2 x 0.3 220 1.5 1 1
1 Medical Version (M5) 2 x 10 220 - - 1
2 Medical Version (M5) 2 x 4 220 - - 1
4 Medical Version (M5) 2 x 1.5 220 - - 1 6 Medical Version (M5) 2 x 0.8 220 - - 1 8 Medical Version (M5) 2 x 0.6 220 - - 1 10 Medical Version (M5) 2 x 0.3 220 - - 1 Diagrams Standard version N PE L Cx Cy2 Cy2 PE’ R Cx Cy1 Cy1 1) 2) 1) Line 2) Load Standard version N PE L Cx Cy2 Cy2 PE’ R Cx Cy1 Cy1 1) 2) 1) Line 2) Load Medical Version (M5) N PE L Cx PE’ R Cx 1) 2) 1) Line 2) Load Medical Version (M5) N PE L Cx PE’ R Cx 1) 2) 1) Line 2) Load Derating Curves 1-pole Admissible power acceptance in Watt02 04 06 08 0 100 I = << In I = 0.7 In I = 1.0 In 2.0 1.5 1.0 0.5 0.0 Ambient air temperature Ta °C 2-pole Admissible power acceptance in Watt 02 04 06 08 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.6 0.6 0.4 0.8 1.2 1.0 1.4 Ambient air temperature Ta °C
Power Entry Modules with Line FilterDD14 https://www.schurter.com /PG06 EMC Products Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version 1 A 2 A 4 A 6 A 8 A 10 A Medical version (M5) 1 A 2 A 4 A 6 A 8 A 10 A All Variants Rated Current [A] Filter-Type Mounting Fuseholder Line Switch Illumination Color Order Number
1 Standard version Screw-on A 2-pole 2-pole non-illuminated black 3-103-776 █
2 Standard version Screw-on A 2-pole 2-pole non-illuminated black 3-103-777 █
4 Standard version Screw-on A 2-pole 2-pole non-illuminated black 3-103-778 █
6 Standard version Screw-on A 2-pole 2-pole non-illuminated black 3-102-850 █
6 Standard version Screw-on B 2-pole 2-pole non-illuminated black 3-102-852 █
6 Standard version Snap-in 2-pole 2-pole non-illuminated black 3-102-854 █
8 Standard version Screw-on A 2-pole 2-pole non-illuminated black 3-103-779 █
10 Standard version Screw-on A 2-pole 2-pole non-illuminated black 3-103-780 █
10 Standard version Snap-in 2-pole 2-pole non-illuminated black 3-103-789 █
10 Standard version Screw-on B 2-pole 2-pole non-illuminated black 3-105-326 █
1 Medical Version (M5) Screw-on A 2-pole 2-pole non-illuminated black 3-104-202
2 Medical Version (M5) Screw-on A 2-pole 2-pole non-illuminated black 3-104-203
4 Medical Version (M5) Screw-on A 2-pole 2-pole non-illuminated black 3-104-204
6 Medical Version (M5) Screw-on A 2-pole 2-pole non-illuminated black 3-104-205
8 Medical Version (M5) Screw-on A 2-pole 2-pole non-illuminated black 3-104-206
Power Entry Modules with Line Filter DD14https://www.schurter.com /PG06 EMC Products Rated Current [A] Filter-Type Mounting Fuseholder Line Switch Illumination Color Order Number
10 Medical Version (M5) Screw-on A 2-pole 2-pole non-illuminated black 3-104-207 █
█ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER 10 A version only IEC approval. The fuse drawer is not included and must be ordered separately (see required accessory). Packaging unit 10 Pcs Required Accessory Fusedrawer for Fuse Links 5x20 mm, with or without Voltage Selector Insert Accessories Wire Harness Wire harness for SCHURTER products Assorted Covers Rear Cover RC320 Rear Cover for Power Entry Module
Power Entry Modules with Line FilterDD14 https://www.schurter.com /PG06 EMC Products Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete 4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with pro- tection class I 4787 4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder / Quick Connect, 10 A, Suitable for appliances with protection class I 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4782
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06
4781 Mounting: Power Cord, Cable, Connector: IEC C15 4781
4784 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C15 4784
... Mating Outlets/Connectors shuttered Connector Overview complete
4783 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4783
Power Cord Overview complete VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black VAC13KS The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 04.01.2022