Technical content
Power Entry Modules with Line Filter DD2 www.schurter.com/pg06 EMC Products IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole Standard- or Medical-Filter C14 70° C
Description
- Panel Mount: Screw-on from front side - 4 Functions: Appliance Inlet Protection class I, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter DD11 - Alternative: version for snap-in mounting KMF Approvals - VDE License Number: 40001522 - UL License Number: E72928 Characteristics - Ultra-compact design. Ideal for low profile designs Aluminum case provides good shielding - All single elements are already wired - Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front For added safety "Extra-Safe" fuse drawers are available - Ideal for application with high transient loads Designed for standard and medical applications - Qualified for use in equipment according IEC/EN 60950 Other versions on request - Solder terminals - Fuse drawer 1-pole, plus spare fuse case - Fuse drawer 2-pole, with shorting bar - Other rocker marking - Line switch, illuminated - Line switch 1-pole - Medical version M80 - Class X1- and Y1-capacitors for enhanced withstand voltage - Protection class II, 70°C References General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories T echnical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 8 A @ Ta 40 °C / 250 VAC; 60 Hz Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (1 min/50 Hz) Allowable Operation Temp. -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 Degree of Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class 1 acc. to IEC 61140 Terminal Quick connect terminals 6.3 x 0.8 mm Panel Thickness s Screw-on mounting: max 8 mm Mounting screw torque max 0.5 Nm Material: Housing Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C14 acc. to IEC/EN 60320-1 UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 Fuseholder 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Power Acceptance @ Ta > 23°C Admissible power acceptance at hig- her ambient temperature see derating curves Line Switch Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical details Line Filter Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details MTBF > 2'000'000 h acc. to MIL-HB-217 F
Power Entry Modules with Line FilterDD2 www.schurter.com/pg06 EMC Products Dimensions 55.4 mm Screw version 46.7 31.5 27.7 3.25 10.3 ±0.10 90˚ 45.39.8 3.4 55 5.9 29.8 49.3 ±0.15 ±0.10 R 4.6 ±0.10 3.4 PEN 15.1 1.3 48.5 L T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 10 100 2.2 1 2 Standard Version 2 x 4 100 2.2 1 4 Standard Version 2 x 1.5 100 2.2 1 6 Standard Version 2 x 0.8 100 2.2 1 8 Standard Version 2 x 0.6 100 2.2 1 10 Standard Version 2 x 0.3 100 2.2 1
1 Medical Version (M5) 2 x 10 100 - 1
2 Medical Version (M5) 2 x 4 100 - 1
4 Medical Version (M5) 2 x 1.5 100 - 1 6 Medical Version (M5) 2 x 0.8 100 - 1 8 Medical Version (M5) 2 x 0.6 100 - 1 10 Medical Version (M5) 2 x 0.3 100 - 1 Diagrams Standard version non illuminated 1) Line 2) Load Medical version M5 non illuminated 1) Line 2) Load Derating Curves 1-poleAdmissible power ac- ceptance in Watt 0 2 0 4 0 6 0 8 0 100 I = << In I = 0.7 In I = 1.0 In 2.0 1.5 1.0 0.5 0.0 Ambient air temperature Ta °C 2-poleAdmissible power ac- ceptance in Watt per pole0 2 0 4 0 6 0 8 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.6 0.6 0.4 0.8 1.2 1.0 1.4 Ambient air temperature Ta °C
Power Entry Modules with Line Filter DD2 www.schurter.com/pg06 EMC Products Attenuation Loss - - - - differential mode _____ common mode Standard version 1 A 2 A 4 A 6 A 8 A 10 A Medical version (M5) 1 A 2 A 4 A 6 A 8 A 10 A Variants Fuse drawer must be ordered separately (see accessories). Fingergrip and Extra Safe. The same drawer as used by type KEA. Rated Current [A] Filter-Type Fuseholder Line Switch Order Number 1 Standard Version 1-pole 2-pole DD12.1111.111 2 Standard Version 1-pole 2-pole DD12.2111.111 4 Standard Version 1-pole 2-pole DD12.4111.111 6 Standard Version 1-pole 2-pole DD12.6111.111 8 Standard Version 1-pole 2-pole DD12.8111.111 10 Standard Version 1-pole 2-pole DD12.9111.111 1 Standard Version 2-pole 2-pole DD12.1121.111 2 Standard Version 2-pole 2-pole DD12.2121.111 4 Standard Version 2-pole 2-pole DD12.4121.111 6 Standard Version 2-pole 2-pole DD12.6121.111 8 Standard Version 2-pole 2-pole DD12.8121.111 10 Standard Version 2-pole 2-pole DD12.9121.111 1 Medical Version (M5) 2-pole 2-pole DD12.1321.111 2 Medical Version (M5) 2-pole 2-pole DD12.2321.111 4 Medical Version (M5) 2-pole 2-pole DD12.4321.111 6 Medical Version (M5) 2-pole 2-pole DD12.6321.111 T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 10 100 2.2 1 2 Standard Version 2 x 4 100 2.2 1 4 Standard Version 2 x 1.5 100 2.2 1 6 Standard Version 2 x 0.8 100 2.2 1 8 Standard Version 2 x 0.6 100 2.2 1 10 Standard Version 2 x 0.3 100 2.2 1 4 Medical Version (M5) 2 x 1.5 100 - 1 6 Medical Version (M5) 2 x 0.8 100 - 1 8 Medical Version (M5) 2 x 0.6 100 - 1 10 Medical Version (M5) 2 x 0.3 100 - 1
Power Entry Modules with Line FilterDD2 www.schurter.com/pg06 EMC Products Rated Current [A] Filter-Type Fuseholder Line Switch Order Number 8 Medical Version (M5) 2-pole 2-pole DD12.8321.111 10 Medical Version (M5) 2-pole 2-pole DD12.9321.111 10 A version only approved up to 8 A at UL. Packaging unit 20 Pcs Required Accessory Fusedrawer with and without Voltage Selector Insert Fingergrip, 2-pole 4301.1401 Extra-Safe, 2-pole 4301.1403 Fingergrip, 1-pole 4301.1405 Extra-Safe, 1-pole 4301.1407 ... Accessories Assorted Covers Rear Cover 0859.0076 Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 5092 Appliance Outlet further types to DD12 Connector Overview complete IEC Connector C15, Rewireable, Straight 0101 IEC Connector C15A, Rewireable, Straight 0102 IEC Connector C15A, Rewireable, Straight 0102-G IEC Connector C15A, Rewireable, Angled 0112 IEC Connector C13, Rewireable, Angled 4012 Connector further types to DD12 ...
Power Entry Modules with Line Filter DD2 www.schurter.com/pg06 EMC Products Category / Description Power Cord Overview complete Power Cord with IEC Connector C13, Angled 0311 Power Cord with IEC Connector C13, Angled 3011 Power Cord with IEC Connector C13, Angled 3012 Power Cord with IEC Connector C13, Angled 3013 Power Cord with IEC Connector C13 3020 Power Cord further types to DD12 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments.