DCG12-200 POWER-SONIC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

TERMINALS: (mm) DIMENSIONS: inch (mm) PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) Nominal Capacity 20-hr. (10.0A to 10.80 volts) 10-hr. (18.6A to 10.50 volts) 5-hr. (32.0A to 10.50 volts) 3-hr. (49.0A to 10.50 volts) 1-hr. (110A to 10.00 volts) 200.0 AH 186.0 AH 160.0 AH 147.0 AH 110.0 AH Approximate Weight 138.7 lbs. (62.9 kg) Internal Resistance (approx.) 3.4 milliohms Shelf Life (% of nominal capacity at 68°F (20°C)

1 Month

3 Month

6 Month

97% 91% 83% Operating Temperature Range Charge Discharge Case ABS Plastic Recommended Power Sonic Chargers PSC-1220000-PC www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation

7550 Panasonic Way, San Diego,

T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA)

3 Buckingham Square,

Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com

FEATURES

  • Thixotropic gel electrolyte for enhanced performance
  • Valve regulated, maintenance free spill proof construction
  • Specifically engineered for cyclic applications
  • Power/volume ratio yielding excellent energy density
  • Gas recombination technology
  • Rugged vibration and impact resistant ABS case and cover (UL94-HB) Also available to UL94-V0 APPROVALS and C.A.B. certified
  • U.L recognized
  • ISO9001:2015 – Quality management systems Solar Wind Mobility Golf Carts RECHARGEABLE DCG 12-200 12 Volt 200 A.H. @ 20-hr. rate to 1.80V 186 A.H. @ 10-hr. rate to 1.80V GEL BATTERY Power-Sonic Corporation BAT TE RYMUST B EREC YC LED Pb NONSPILLABLE www.power-sonic.com MH20845 L HT W H Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. POWER-GEL SERIES L: 20.55 (522) W: 9.45 (240) H: 8.58 (218) HT: 8.82 (224) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. Rev1: 11/18 DCG12-200 12V 200.0 AH @ 20-hr. 12V 186.0 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery DCG – Deep Cycle Gel Series T11: Threaded insert with 8mm stud fastener Torque: 11.0~14.7 Nxm 20mm 7mm

www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com DCG12-200 12V 200.0 AH @ 20-hr. 12V 186.0 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery DCG – Deep Cycle Gel Series CYCLE LIFE IN RELATION TO DEPTH OF DISCHARGE GENERAL RELATION OF CAPACITY VS. STORAGE TIME 100 Number of Cycles Extracted Capacity (%) 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Acc. to IEC 896-2 (25°C/77°F) Residual average capacity as % of C20 Cycle Life in Relation to Depth of Discharge 0 5 10 15 20 25 100 120 Storage Time (months) Available Capacity (%) 40°C 30°C 20°C 10°C General Relation of Capacity vs. Storage Time CHARGING Cycle Applications: Apply constant voltage charge at Initial charging current should be set at less than 0.25C Amps. Switch to float charge to avoid overcharging. “Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifications.

APPLICATIONS

A whole range of CYCLIC applications including but not limited to: 100 Number of Cycles Extracted Capacity (%) 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Acc. to IEC 896-2 (25°C/77°F) Residual average capacity as % of C20 Cycle Life in Relation to Depth of Discharge 0 5 10 15 20 25 100 120 Storage Time (months) Available Capacity (%) 40°C 30°C 20°C 10°C General Relation of Capacity vs. Storage Time

  • Solar • Wind • Mobility • Golf Carts CHARGERS Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have difficulty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc. Rev1: 11/18