DCN3-11 OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 24
Technical content
154 Peripheral Devices
General-purpose Peripheral Devices
Ordering Information
- General-purpose Models Peripheral Devices for DeviceNet Communications Product Appearance Model Specifications T -branch Tap for 1 branch line DCN1-1NC Cable wiring direction: Toward top Cable lock direction: From top Connector screw direction: From top Provided with 3 parallel connectors with clamps (XW4G-05C1-H1-D), standard terminating resistor DCN1-1C Cable wiring direction: Toward side Cable screw direction: From top Connector screw direction: From side Provided with 3 parallel connectors with screws (XW4B-05C1-H1-D), standard terminating resistor DCN1-2C Cable wiring direction: Toward top Cable screw direction: From side Connector screw direction: From top DCN1-2R Cable wiring direction: Toward side Cable screw direction: From top Connector screw direction: From top Provided with 3 orthogonal connectors with screws (XW4B-05C1-VIR-D), standard terminating resistor T -branch Tap for 3 branch lines DCN1-3NC Cable wiring direction: Toward top Cable lock direction: From top Connector screw direction: From top Provided with 5 parallel clamp connectors with screws (XW4G-05C1-H1-D), standard terminating resistor DCN1-3C Cable wiring direction: Toward side Cable screw direction: From top Connector screw direction: From side Provided with 5 parallel connectors with screws (XW4B-05C1-H1-D), standard terminating resistor DCN1-4C Cable wiring direction: Toward top Cable screw direction: From side Connector screw direction: From top DCN1-4R Cable wiring direction: Toward side Cable screw direction: From top Connector screw direction: From top Provided with 5 orthogonal clamp connectors with screws (XW4B-05C1-VIR-D), standard terminating resistor Power Supply Tap DCN1-1P Tap provided with 2 connectors, standard terminating resistor, and fuse
Product Appearance Model Specifications Connectors XW4G-05C1-H1-D Parallel clamp connector with screws Connector insertion and wiring both performed horizontally. XW4G-05C4-TF-D Parallel multi-branching clamp connector with screws Connector insertion and wiring performed in same direction. XW4B-05C1-H1-D Parallel connector with screws Connector insertion and wiring performed in same direction. XW4B-05C4-T-D Parallel, screw-less, multi-branching connector Connector insertion and wiring performed in same direction. XW4B-05C4-TF-D Parallel, multi-branching connector with screws Connector insertion and wiring performed in same direction. XW4B-05C1-VIR-D Orthogonal connector with screws Connector insertion and wiring performed at a right angle. DeviceNet Standard Cables Thin Cables DCA1-5C10(-B) Outer diameter: 7.00 mm Length: 100 m DCA1-5C10-B: Cable color: Blue DCA1-5C10: Cable color: Gray Thick Cables DCA2-5C10(-B) Outer diameter: 11.6 mm Length: 100 m DCA2-5C10-B: Cable color: Blue DCA2-5C10: Cable color: Gray Terminal-block Terminator DRS1-T Resistance of 121 Ω
156 Peripheral Devices
- Peripheral Devices for Flat Cables Specifications
- General-purpose Models (T-branch Taps) Product Appearance Model Specifications Connector for Flat Cable DCN4-SF4D Connector with lock screws for crimping flat cable Conversion Connector for Standard Thin Cable and Flat Cable DCN4-BR4D Used as a set with a DCN4-TR4 when Thin Cable is branched on a branch line. Power Supply Terminal Block with Terminating Resistance for Flat Cable DCN4-TP4D Can be used to supply communications power from terminals when Flat Cable is used. Flat Connector Socket DCN4-TR4 Used as a set with a DCN4-BR4 Flat Connector Plug in the following applications.
- Extending the trunk line T -branching the trunk line into branch lines Used alone in the following applications. Connecting a DCN4-TM4 Terminating Resistor to the trunk line Flat Connector Plug DCN4-BR4 Used as a set with a DCN4-TR4 Flat Connector Socket in the following applications. Extending the trunk line T -branching the trunk line into branch lines Terminating Resistor DCN4-TM4 Connector terminating resistor for flat cable. Attached to the DCN4-TR4 Flat Connector Socket at the end of the trunk line. Flat Cable DCA4-4F10 Four-core flat cable (UL 2555) Length: 100 m Conductor diameters: 0.75 mm 2 x 2, 0.5 mm2 x 2 Simple Manual Crimp Tool DWT-A01 Crimping tool for DCN4-TR4 Flat Connector Socket or DCN4-BR4 Flat Connector Plug. Rated current Between main lines: 8 A (power supply line) and 2 A (signal line) Between main and branch lines: 3 A (power supply line) and 1 A (signal line) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 500 VAC for 1 min, leakage current: 1 mA max. Ambient operating temperature 0°C to 55°C
Dimensions (Unit: mm)
- General-purpose Models 74.5 67.5 20 20 30.9 20.5 14.15±0.1 74.5±0.1 Two, 3.5±0.1 dia. or M3 TRUNK LINE 1 TRUNK LINE Terminator connection4 Internal CircuitT-branch Tap for 1 branch line DCN1-1NC (With Three Branching Connectors) Mounting Dimensions Terminal No. Name 1 V- 2C A N L
3 DRAIN
15.5 15.5 20.5 31.27 7Socket for terminator connection Note 97±0.3 14±0.3 Two, 3.5 dia. or M3 54321 5 4 3 2 1 54321 CN4 CN3 CN1 CN2 Branch line Main line Main line Note: When connecting a branch line to the main line, connect the main line to the connector marked with an asterisk because the resistance between the asterisks is minimal. Internal CircuitT-branch Tap for 1 branch line DCN1-1C (With Three Branching Connectors) Terminal No. Name 1 V- 2C A N L 2.3 45 14 14±0.1 97±0.1 30.9 20.5 Two, 3.5±0.1 dia. or M3 TRUNK LINE 321 TRUNK LINE Terminator connection4 Internal CircuitT-branch Tap for 3 branch lines DCN1-3NC (With Five Branching Connectors) Mounting Dimensions Terminal No. Name 1 V- 2C A N L
158 Peripheral Devices
5 4 3 2 1 5 4 3 2 15 4 3 2 1 142 135 15.5 31.27 20.5 15.5 Socket for terminator Note 142±0.3 14±0.3 Two, 3.5 dia. or M3 Note: When connecting a branch line to the main line, connect the main line to the connector marked with an asterisk because the resistance between the asterisked portion is minimal. Internal CircuitT-branch Tap for 3 branch lines DCN1-3C (With Five Branching Connectors) Terminal No. Name 1 V- 2C A N L V−'L' S' S V−V+ H' V+' V+H S L CN4 Two, 3.5 dia. or M3 126.5 119.5 15.5 15.5 119.5±0.3 14±0.3 Two, 3.5 dia. 29.9 20.5 30.9 45.3 112.5 Socket for terminator connection Connectors on Cable side Fuse Terminal block on power supply side Internal CircuitPower Supply Tap DCN1-1P (With Two Branching Connectors) Terminal No. Name V- V- LC A N L S DRAIN HC A N H V+ V+ Mounting Dimensions 30±0.2 Two, 4.2 dia. or M4 21 max. 20 max. 41 max. 20±0.15 30±0.2 Two, 4.4 dia. +0.1 DRS1-T (Terminal-block Terminator) Mounting Dimensions
- Flat Cable 1.45 18.14 30.20 12.6411.1 38.55 Connector for Flat Cable DCN4-SF4D 21.3 (23) 8.3 9.2 9.5 Conversion Connector for Standard Thin Cable and Flat Cable DCN4-BR4D 33.60 13.50 16.20 4.55 6 20.90 Power Supply Terminal Block with Terminating Resistance for Flat Cable DCN4-TP4D 22 17 17.8 30.7 9.5 13.8 Flat Connector Socket DCN4-TR4 21.3 (23) 8.3 9.2 9.5 Flat Connector Plug DCN4-BR4
160 Peripheral Devices
■I/O Connectors for Connector Terminals
- MIL Connectors Applicable Connectors * DeviceNet connectors for multi-drop wiring cannot be used with the Hood Cover. Cable Models Applicable Cables with Connectors
- Cables with Connectors (1-to-2 Connection)/G79-@@-@-D@
- Cables with Connectors (1-to-1 Connection)/XW2Z-C@@K
- Cables with Crimp Terminals (at the End of Loose Wires)/G79-Y@C-D1 I/O Peripheral Devices Type Model Remarks Flat Cable Pressure-welded Connectors XG4M-4030-T Pressure-welded Connectors with Loose Wires Socket XG5M-4032-N Corresponding to 24 AWG XG5M-4035-N Corresponding to 28 to 26 AWG Semicover XG5S-2001 Hood Cover * XG5S-4022 Type Model Connected device Applicable models Cable with Connectors (1:2) G79-I@@-@@-D1 G7TC/G70D/G70A DRT2-ID32ML G79-M@@-@@-D1 DRT2-MD32ML G79-O@@-@@-D1 DRT2-OD32ML/DRT1-OD32ML-1 G79-I@@-@@-D2 DRT2-ID32ML-1 G79-M@@-@@-D2 DRT2-MD32ML-1 Cable with Connector (1:1) XW2Z-C@@K -- All modelsCable with Loose Wires with Crimp Terminals G79-Y@00C-D1 Cable with Loose Wires G79-A@00C-D1 Appearance Cable length (mm) Model 500 250 G79-I50-25-D1 750 500 G79-I75-50-D1 500 250 G79-O50-25-D1 750 500 G79-O75-50-D1 500 250 G79-M50-25-D1 750 500 G79-M75-50-D1 500 250 G79-I50-25-D2 750 500 G79-I75-50-D2 500 250 G79-M50-25-D2 750 500 G79-M75-50-D2 Appearance Cable length (mm) Model
250 XW2Z-C25K
500 XW2Z-C50K
Appearance Cable length (mm) Model 1,000 G79-Y100C-D1 2,000 G79-Y200C-D1 5,000 G79-Y500C-D1 A B Length without any bending A B (120) L L Connected to device 300 Terminal A Terminal B
- Cables with Loose Wires/G79-A@C Appearance Cable length (mm) Model 2,000 G79-A200C-D1 5,000 G79-A500C-D1L300 Connected to device Terminal A Terminal B
162 Peripheral Devices
■I/O Connectors for MULTIPLE I/O TERMINALs Applicable Connectors Applicable Cables with Connectors (Fujitsu Connectors)
- Cables with Connectors (1-to1 Connection)/G79-@C For Digital Input/Output (16 Points)
- Cables with Connectors (1-to-2 Connection)/G79-O@C-@, G79-I@C-@ For Digital Input/Output (32 Points) For Digital Input/Output (16 Points) For Digital Input/Output (32 Points) Type Model Remark Connectable model Molex connector Crimped terminals Housing 50-57-9403 Digital I/O Units GT1-ID16MX(-1)/GT1-OD16MX(-1) Analog I/O Units GT1-AD08MX/GT1-DA04MX Chain terminal 16-02-0069 Corresponding to 24 to 30 AWG 16-02-0086 Corresponding to 22 to 24 AWG Loose terminal 16-02-0096 Corresponding to 24 to 30 AWG 16-02-0102 Corresponding to 22 to 24 AWG Press-fit tool 57036-5000 Corresponding to 22 to 26 AWG 57037-5000 Corresponding to 24to 30 AWG Fujitsu connector (16 points) Soldered terminals FCN361J024-AU Pressure-welded terminals FCN367J024-AU/F Crimped terminals FCN363J024-AU Fujitsu connector (32 points) Soldered terminals FCN361J040-AU Digital I/O Units GT1-ID32ML(-1)/GT1-OD32ML(-1)Pressure-welded terminals FCN367J040-AU/F Crimped terminals FCN363J040-AU OMRON D-sub connector Pulg XM2A-2501 Digital I/O Units GT1-ID16DS(-1)/GT1-OD16DS(-1)Hood XM2S-2513 #4-40UNC inch screws I/O classification Model Connectable model Digital input, 16 points XW2Z-@@@A Digital I/O Units GT1-ID16ML(-1)G79-@C Digital output, 16 points XW2Z-@@@A Digital I/O Units GT1-OD16ML(-1)G79-@C Digital input, 32 points XW2Z-@@@B Digital I/O Units GT1-ID32ML(-1)G79-I@C@ Digital output, 32 points XW2Z-@@@B Digital I/O Units GT1-OD32ML(-1)G79-O@C@ Appearance Cable length (mm) Model 1,000 G79-100C 1,500 G79-150C 2,000 G79-200C 3,000 G79-300C 5,000 G79-500C Appearance Cable length (mm) Model Input Output 1,000 750 G79-I100C-75 G79-O100C-75 1,500 1,250 G79-I150C-125 G79-O150C-125 2,000 1,750 G79-I200C-175 G79-O200C-175 3,000 2,750 G79-I300C-275 G79-O300C-275 5,000 4,750 G79-I500C-475 G79-O500C-475 Appearance Cable length (mm) Model
500 XW2Z-050A
1,000 XW2Z-100A 1,500 XW2Z-150A 2,000 XW2Z-200A 3,000 XW2Z-300A 5,000 XW2Z-500A Appearance Cable length (mm) Model
500 XW2Z-050B
1,000 XW2Z-100B 1,500 XW2Z-150B 2,000 XW2Z-200B 3,000 XW2Z-300B 5,000 XW2Z-500B L A B Length without any bending A B L L
■I/O Connector for Programmable Slaves Applicable Connector Terminal Conversion Units Applicable Cables with Connectors
- Cables with Connectors/XW2Z For Digital Input/Output (16 Points) Applicable cable Connected product Remarks XW2Z-@@@A XW2D-20G6 Slim type (with M3 screw terminals) XW2B-20G4 Flat cable connectors (with M3 terminal screws for flat-blade screwdriver) Appearance Cable length (mm) Model
1,000 XW2Z-100A 1,500 XW2Z-150A 2,000 XW2Z-200A 3,000 XW2Z-300A 5,000 XW2Z-500A L
164 Peripheral Devices
Peripheral Devices for Environment-resistive Slaves
- Environment-resistive Connection Products (for Thin Cable, M12 Micro Connectors) Peripheral Devices for DeviceNet Communications Product Appearance Model Specifications Sealed Assembling-type Connector (male) XS2G-D5S7 For communications (plug) Sealed Assembling-type Connector (female) XS2C-D5S7 For communications (socket) Sealed T -branch Connector DCN2-1 For 1 branch line Sealed Connector with Terminating Resistor DRS2-1 Plug DRS2-2 Socket Cables with Sealed Connectors DCA1-5CNC5W1 Length (L): 0.5 m Cable with connectors on both ends DCA1-5CN01W1 Length (L): 1 m DCA1-5CN02W1 Length (L): 2 m DCA1-5CN03W1 Length (L): 3 m DCA1-5CN05W1 Length (L): 5 m DCA1-5CN10W1 Length (L): 10 m DCA1-5CNC5F1 Length (L): 0.5 m Cable with connector on one end (socket) DCA1-5CN01F1 Length (L): 1 m DCA1-5CN02F1 Length (L): 2 m DCA1-5CN03F1 Length (L): 3 m DCA1-5CN05F1 Length (L): 5 m DCA1-5CN10F1 Length (L): 10 m DCA1-5CNC5H1 Length (L): 0.5 m Cable with connector on one end (plug) DCA1-5CN01H1 Length (L): 1 m DCA1-5CN02H1 Length (L): 2 m DCA1-5CN03H1 Length (L): 3 m DCA1-5CN05H1 Length (L): 5 m DCA1-5CN10H1 Length (L): 10 m Shielded Panel-mounting Connectors (female) DCA1-5CNC5P1 Panel-mounting connector (socket) with 0.5-m cable XS2P-D522-2 Panel-mounting connector socket Shielded Panel-mounting Connectors (male) DCA1-5CNC5M1 Panel-mounting connector (plug) with 0.5-m cable XS2M-D524-4 Panel-mounting connector (plug) with solder-cup terminals Waterproof cover (for socket) XS2Z-22 Used to cover an unused connector section Dust cover (for socket) XS2Z-15 L L 50 mm L 50 mm
- Environment-resistive Models (for Thin Wires and M12 Micro Connectors) Product Appearance Model Specifications Sealed T -branch Connector DCN2-1S For 1 branch line Sealed Assembling type Connector (female) DRS2-1S Plug DRS2-2S Socket Connectors with Shielded Cables DCA1-5CSC5W1 Length (L): 0.5 m Cable with connectors on both ends DCA1-5CS01W1 Length (L): 1 m DCA1-5CS02W1 Length (L): 2 m DCA1-5CS03W1 Length (L): 3 m DCA1-5CS05W1 Length (L): 5 m DCA1-5CS10W1 Length (L): 10 m DCA1-5CSC5F1 Length (L): 0.5 m Cable with connector on one end (socket) DCA1-5CS01F1 Length (L): 1 m DCA1-5CS02F1 Length (L): 2 m DCA1-5CS03F1 Length (L): 3 m DCA1-5CS05F1 Length (L): 5 m DCA1-5CS10F1 Length (L): 10 m DCA1-5CSC5H1 Length (L): 0.5 m Cable with connector on one end (plug) DCA1-5CS01H1 Length (L): 1 m DCA1-5CS02H1 Length (L): 2 m DCA1-5CS03H1 Length (L): 3 m DCA1-5CS05H1 Length (L): 5 m DCA1-5CS10H1 Length (L): 10 m Shielded Branch Relay Box DCN2-S4C5H1 4 ports, 0.5-m cable DCN2-S8C5H1 8 ports, 0.5-m cable L L 50 mm L 50 mm
166 Peripheral Devices
- Environment-resistive Models for Thick Wires with 7/8-16UN Mini Connectors Product Appearance Model Specifications Sealed T -branch Connector DCN3-11 T -branch Connector DCN3-12 T -branch Connector (Branch connector is M12.) Sealed Connector with Terminating Resistor DRS3-1 Plug Cables with Sealed Connectors DCA2-5CN01W1 Length (L): 1 m Cable with connectors on both ends DCA2-5CN02W1 Length (L): 2 m DCA2-5CN05W1 Length (L): 5 m DCA2-5CN10W1 Length (L): 10 m DCA2-5CN01F1 Length (L): 1 m Cable with connector on one end (socket) DCA2-5CN02F1 Length (L): 2 m DCA2-5CN05F1 Length (L): 5 m DCA2-5CN10F1 Length (L): 10 m DCA2-5CN01H1 Length (L): 1 m Cable with connector on one end (plug) DCA2-5CN02H1 Length (L): 2 m DCA2-5CN05H1 Length (L): 5 m DCA2-5CN10H1 Length (L): 10 m DCA1-5CN01W5 Length (L): 1 m Cable with connectors on both ends Thin cable M12 socket DCA1-5CN02W5 Length (L): 2 m DCA1-5CN05W5 Length (L): 5 m DCA1-5CN10W5 Length (L): 10 m Panel-mounting Connector (female) DCA2-5CNC5P1 Panel-mounting connector (socket) with 0.5-m cable Panel-mounting Connector (male) DCA2-5CNC5M1 Panel-mounting connector (plug) with 0.5-m cable Panel-mounting Connector (male) XS4M-D521-1 Panel-mounting connector (plug) DIP terminals Waterproof Cap (for Plug) - XS4Z-11 Used to cover an unused connector section. Waterproof Cap (for Socket) - XS4Z-12 L mmL mmL L
- Environment-resistive Connection Products (for Thin Cable, M12 Micro Connectors)
- Environment-resistive Models (for Thin Wires and M12 Micro Connectors)
- Environment-resistive Models for Thick Wires with 7/8-16UN Mini Connectors * The rated current between thick wires is 8 A. Type Item Connectors with Cables DCA1-5CN@@@1 T-branch Connector DCN2-1 Assembling-type Connector XS2@-D5S7 Connectors with Terminating Resistor DRS2-@ Rated current 3 A Rated voltage 125 VDC Contact resistance (connector) 40 mΩ max. (at 20 mVDC max. and 100 mA max.) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength (connector) 1,500 VAC for 60 seconds (leakage current: 1 mA max.) Ambient operating temperature -20°C to 65°C Storage temperature range -25°C to 70°C Degree of protection IEC IP67 Insertion durability 200 times Cable strength 98 N for 15 s -- Vibration resistance No current interruptions of more than 1 µs while performing simple vibrations at either 10 to 500 Hz with 1.52-mm full amplitude or at acceleration 100 m/s2, whichever is smaller Type Item Connectors with Cables DCA1-5CS@@@1 T-branch Connector DCN2-1S Connectors with Terminating Resistor DRS2-@S Branch Relay Box DCN2-S@C5H Rated current 3 A Rated voltage 125 VDC Contact resistance (connector) 40 mΩ max. (at 20 mVDC max. and 100 mA max.) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength (connector) 1,500 VAC for 60 seconds (leakage current: 1 mA max.) 1,000 VAC for 60 seconds Ambient operating temperature -20°C to 65°C Storage temperature range -25°C to 70°C Degree of protection IEC IP67 Insertion durability 200 times Cable strength 98 N for 15 s -- Vibration resistance No current interruptions of more than 1 µs while performing simple vibrations at either 10 to 500 Hz with 1.52-mm full amplitude or at acceleration 100 m/s2, whichever is smaller Lock strength Pulling: 100 N/15 s, Rotating: 1 N·m/15 s Lock force 0.1 to 0.25 N·m Type Item Connectors with Thick Cables DCA2-5CN@@@1 Connectors with Thin Cables DCA1-5CN@@W5 T-branch Connector DCN3-11 T-branch Connector DCN3-12 Connectors with Terminating Resistor DRS3-1 Panel Mounting Connector DCA2-5CNC5P1 Panel Mounting Connector XS4M-D521-1 Rated current 8 A3 A8 A 3 A * 8 A Rated voltage 125 VDC Contact resistance (connector) 30 mΩ max. (at 20 mVDC max. and 100 mA max.) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength (connector) 1,500 VAC for 60 seconds (leakage current: 1 mA max.) Ambient operating temperature -20°C to 65°C Storage temperature range -25°C to 70°C Degree of protection IEC IP67 Insertion durability 200 times Cable strength 98 N for 15 s -- 98 N for 15 s -- Vibration resistance No current interruptions of more than 1 µs while performing simple vibrations at either 10 to 500 Hz with 1.52-mm full amplitude or at acceleration 100 m/s2, whichever is smaller
168 Peripheral Devices
- Environment-resistive Connection Products (for Thin Cable, M12 Micro Connectors) L (cable length) 44.71 M12 M12 Cables with Connectors on Both Ends DCA1-5CN@@W1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V -
4 White CAN H
40.7 M12 L (cable length) Cables with Connector on Single End (Socket) DCA1-5CN@@F1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V - L (cable length) 44.7 Cables with Connector on Single End (Plug) DCA1-5CN@@H1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V - (56) 24.717.7 32.1 13.6 13.6 CN0 CN1 CN2 4.5 dia. 8 dia. (Countersinking: 2) 12345 Socket CN1 (OUT) Socket CN2 (OUT)Plug CN0 (IN) M12 8.5 dia.14.9 dia. 13.6 dia. 44.7 T-branch Connector DCN2-1 Wiring Terminal No. Name 1S H I E L D 2V + 3V - 4C A N H 5C A N L Connectors with Terminating Resistance DRS2-1 (Plug) DRS2-2 (Socket) Connections Diagram Wiring Note: Terminating resistance (121 Ω) is connected between terminals 4 and 5. Terminal No. Name
1 DRAIN : NC
2V + : N C 3V - : N C
4 CAN H :
CAN L : 121 Ω5 Note: The diagram shows the DRS2-1 (plug).
Panel-mounting Connector (Socket) with 0.5 m Cable DCA1-5CNC5P1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V - 14 dia. 3 1.5 M16 × 1M16 nut M12 × 1 20 dia. 16 dia.+0.3 0 7+0.2 25.5 20.5 5 38.7 6.8 2.5 1 2 3 2 Panel-mounting Connector (Socket), Solder-cup Terminals XS2P-D522-2 50500 Heat-shrinking tube Rubber bushingM16 nut 2 1 XS2M-D524-4 Panel-mounting Connector (Plug) with 0.5 m Cable DCA1-5CNC5M1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V - Panel Cutout DimensionsM16 × 1M16 nut M12×1 5 dia. 16 dia. 1.5 6.5 8.7 27.7 18.7 4.5 1.5 5.5 3.5 Sealing rubberM12×1 7+0.1 20 dia. 4 1 16 dia.+0.1 Panel-mounting Connector (Socket), Solder-cup Terminals XS2M-D524-4
170 Peripheral Devices
- Environment-resistive Models (for Thin Wires and M12 Micro Connectors) M12 M12 44.7 L (cable length) Cables with Connectors on Both Ends DCA1-5CS@@W1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V -
5B l u e C A N LCables with Connector on Single End (Socket) DCA1-5CS@@F1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V - L (cable length) 40.7 50+20 −10 L (cable length) 44.71 M12 50+20 −10 Cables with Connector on Single End (Plug) DCA1-5CS@@H1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V - Socket CN1 (OUT) Socket CN2 (OUT)Plug CN0 (IN) 8.5 dia. M12 14.9 dia. 13.6 dia. 44.7 32.1 13.6 (56) 24.717.7 13.6 CN0 CN1 CN2 4.5 dia. 8 dia. (Countersinking: 2) 5 4 T-branch Connector DCN2-1S Wiring Terminal No. Name 1S H I E L D 2V + 3V - 4C A N H 5C A N L Connectors with Terminating Resistance DRS2-1S (Plug) DRS2-2S (Socket) Connections Diagram Wiring Note: Terminating resistance (121 Ω) is connected between terminals 4 and 5. Terminal No. Name 2V + : N C 3V - : N C CAN L : 121 Ω5 Note: The diagram shows the DRS2-1 (plug).
4.5 dia.4.5 4.5 dia. 30.527 1 2 M12 2 3 5 1 500+60 27 54 20 13.5 PORT 1 PORT 2 PORT 3 PORT 4 Shielded Branch Relay Box with Four Ports DCN2-S4C5H1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V - Shielded Branch Relay Box with Eight Ports DCN2-S8C5H1 Wiring Terminal No. Color Name 1 - DRAIN 2R e d V + 3B l a c k V - 20 13.5 4.5 dia.4.5 4.5 dia. dia. 30.5272727 127 2 3 5 1 27 54 PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8Connections Diagram
172 Peripheral Devices
- Environment-resistive Models for Thick Wires with 7/8-16UN Mini Connectors 234 562.5 L 61.2 26 dia. 26 dia. 12 dia. 2 3 4 Thick Cable with Connectors on Both Ends (5 Conductors for Communications) DCA2-5CN@@W1 Wiring Terminal No. Color Name 1 - DRAIN
2 Red V+
3 Black V-
5 Blue CAN L
61.2 L 12 dia. 4 3 2 26 dia. Thick Cable with Connector Socket on One End (5 Conductors for Communications) DCA2-5CN@@F1 Wiring Terminal No. Color Name 1 - DRAIN 62.5 L 12 dia. 2 3 4 26 dia. Thick Cable with Connector Plug on One End (5 Conductors for Communications) DCA2-5CN@@H1 Wiring Terminal No. Color Name 1 - DRAIN 62.5 40.7 L 26 dia. 6 dia. 14.9 dia. 43 5 2 3 4 Thin Cable with Connectors on Both Ends (5 Conductors for Communications) DCA1-5CN@@W5 Wiring Terminal No. Color Name 1 - DRAIN 27 1.7 41 50L 12 dia. M20 × 1.5 20 dia. 2 +0.1 33 min. Thin Cable with Panel-mounting Connector Socket on One End (5 Conductors for Communications) DCA2-5CNC5P1 Wiring Terminal No. Color Name 1 - DRAIN Note: A rubber seal and nut for panel mounting are included.
M20 × 1.5 O-ring 12 dia. 500 3 (sequence pin) Panel-mounting Connector (Plug) with 0.5 m Cable DCA2-5CNC5M1 Wiring Terminal No. Color Name 1 - DRAIN Note: A nut is included. D4N3-11 CN0 CN2 CN1 26 dia. 74.7 14.6 41.7 28.5 4 5 123 25.4 12345 Plug CN0 (IN) Socket CN2 (OUT) Socket CN1 (OUT) T-branch Connector (5 Conductors for Communications, Thick Wire Branch Line) DCN3-11 Wiring Terminal No. Name
1 DRAIN
4 CAN H
5 CAN L
26 dia. 74.7 25.4 CN0 5.5 dia. CN2 CN1 14.6 37.6 31 4 5 2 28.5 5 1 12345 Plug CN0 (IN) Socket CN2 (OUT) Socket CN1 (OUT) T-branch Connector (5 Conductors for Communications, Thin Wire Branch Line) DCN3-12 Wiring Terminal No. Name
174 Peripheral Devices
26 dia. 62.5 M25 × 230 4 8.5 4.5 1.5 dia. 25 dia. 2 +0.1 37 min. 4.8 5, 1.8 dia. 9.1 dia. Connector (Plug) with Terminating Resistance DRS3-1 Panel-mounting Connector (5 Pins for Communications) XS4M-D521-1 Panel Cutout Dimensions Wiring Note: Terminating resistance (121 Ω) is connected between terminals 4 and 5. Terminal No. Name
2 V+ : NC
3 V- : NC
CAN L : 121 Ω PCB Processing Dimensions Note: A rubber seal and nut for panel mounting are included.
- Assembly Connector Plugs for M12 Microconnectors Applicable Cables with Connectors
- Cables with Connector (Socket/Plug) on Both Ends (M12 Microconnectors for Power Supply and I/O)
- Cables with connector plug on One End (M12 Microconnectors for I/O)
- Plugs and Sockets on Y-shaped Joints (M12 Microconnectors for I/O) Note: Use is supported only for Environment-resistive Terminals (DRT2-@D16C(L)(-1)).
- Connector Cover for M12 Microconnectors I/O Peripheral Devices Appearance Applicable cable diameter (mm) Cable direction Number of poles Connection method Crimping Soldering Screws For 6 dia. (5 to 6 dia.) Straight XS2G-D4C1 XS2G-D421 XS2G-D4S1 L-shaped -- XS2G-D422 XS2G-D4S2 For 5 dia. (4 to 5 dia.) Straight XS2G-D4C3 XS2G-D423 XS2G-D4S3 L-shaped -- XS2G-D424 XS2G-D4S4 For 3 dia. (3 to 4 dia.) Straight XS2G-D4C5 XS2G-D425 XS2G-D4S5 L-shaped -- XS2G-D426 XS2G-D4S6 For 7 dia. (6 to 7 dia.) Straight -- -- XS2G-D4S9 For 8 dia. (7 to 8 dia.) XS2G-D4S7 Appearance Cable direction Number of core wires Cable length (m) Standard cable Robot (earthquake-resistant) cable Straight/Straight
1 XS2W-D421-C81-A XS2W-D421-C81-R
2 XS2W-D421-D81-A XS2W-D421-D81-R
5 XS2W-D421-G81-A XS2W-D421-G81-R
L-shaped/L-shaped 2 XS2W-D422-D81-A
5 XS2W-D422-G81-A
Straight/L-shaped 2 XS2W-D423-D81-A
5 XS2W-D423-G81-A
L-shaped/Straight 2 XS2W-D424-D81-A
5 XS2W-D424-G81-A
Appearance Cable direction Number of core wires Cable length (m) Standard cable Straight 0.3 XS2H-D421-AC0-A
4 XS2H-D421-A80-A
4 XS2H-D421-C80-A
Appearance Cable Connector DC models Cable length (m) Model With cable Connectors on both ends
0.5 XS2R-D426-B11-F
1 XS2R-D426-C11-F
2 XS2R-D426-D11-F
3 XS2R-D426-E11-F
2 XS2R-D426-D10-F
5 XS2R-D426-G10-F
Without cable Connectors on both ends -- XS2R-D426-1 Appearance Product Model Application Waterproof cover (socket) XS2Z-22 For covering unused I/O connectors
176 Peripheral Devices
Applicable Cables with Connectors
- Power Supply Connectors (7/8-16UN Miniconnectors) Power Supply Peripheral Devices Appearance Product Cable length L (mm) Model
1 XS4W-D421-101-A
2 XS4W-D421-102-A
5 XS4W-D421-105-A
10 XS4W-D421-110-A
1 XS4F-D421-101-A
2 XS4F-D421-102-A
5 XS4F-D421-105-A
10 XS4F-D421-110-A
1 XS4H-D421-101-A
2 XS4H-D421-102-A
5 XS4H-D421-105-A
10 XS4H-D421-110-A
T -branch Connector -- XS4R-D424-5 Panel mounting connector socket Cable: 50 cm -- XS4P-D421-1C5-A Panel mounting connector plug DIP terminals -- XS4M-D421-1 - Waterproofing Cap for Plug -- XS4Z-11 - Waterproofing Cap for Socket -- XS4Z-12 L L 50 mm L 50 mm
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.