DC60_V01 SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 7
Technical content
Features
- Ratings from 3A to 7A @ 60 VDC
- Bi-Polar Transistor Output
- UL Approved, CE Compliant to EN60950-1
- Improved SEMS Screw and Washer
- Redesigned Housing with Anti-Rotation Barriers
- AC and DC Control
- Epoxy Free Design Control Voltage 3 A 5 A 7 A 3.5-32 VDC DC60S3 DC60S5 DC60S7 90-280 VAC/VDC DC60SA3 DC60SA5 DC60SA7 Description 3 A 5 A 7 A Recommended Operating Voltage [Vdc] 3-48 3-48 3-48 Absolute Maximum Rating [Vdc] 60 60 60 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.1 Maximum Load Current [Adc] (3) 3 5 7 Minimum Load Current [mA] 20 20 20 Maximum Surge Current (10 msec) [Adc] 6 10 14 Maximum On-State Voltage Drop @ Rated Current [Vdc] 1 1.2 1.3 Thermal Resistance Junction to Case (Rjc) [°C/W] 2 2 2 Minimum Heat Sink @ Ambient (for max current = °C/W & Ta) 5 @ 60°C 5 @ 60°C 5 @ 40°C SPECIFICATIONS PRODUCT SELECTION | DC60 SERIES PANEL MOUNT SOLID STATE RELAYS
sensata.comCopyright © 2025 Sensata Technologies, Inc. Input (2) General (2) Description DC Control AC Control Control Voltage Range 3.5-32 VDC 90-280 VAC/VDC Maximum Reverse Voltage -32 VDC — Minimum Turn-On Voltage (4) 3.5 VDC 90 VAC/VDC Must Turn-Off Voltage (5) 1 VDC 10 VAC/VDC Minimum Input Current (For On-State) 2.2 mA 2 mA Maximum Input Current 25 mA 5.5 mA Nominal Input Impedance [Ohm] 1500 60K Maximum Turn-On Time [msec] (6) 0.1 10 Maximum Turn-Off Time [msec] (7) 0.3 40 Description Parameters Dielectric Strength, Input/Output/Base (50 / 60Hz) (2) 4000 Vrms Minimum Insulation Resistance (@500 VDC) (2) 109 Ohm Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -30 to 80°C Ambient Storage Temperature Range -40 to 125°C Weight (typical) 2.46 oz. (17 g) Housing Material UL94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range Load Terminal Screw Torque Range (lb-in/Nm) 18-20 / 2-2.2 SSR Mounting Screw Torque Range (lb-in/Nm) 18-20 / 2-2.2 Input/Load Terminal Screw Torque Range Humidity 85% non-condensing MTBF (Mean Time Between Failures) at 40°C Ambient Temperature (8) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C Ambient Temperature (8) 11,545,504 hours (1,317 years)
sensata.comCopyright © 2025 Sensata Technologies, Inc. WIRING DIAGRAM * Inductive loads must be diode suppressed. Recommended Wire Sizes Terminals Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb) [N] Input 24 AWG (0.2 mm2) / 0.2 [minimum] 10 [44.5] 2 x 12 AWG (3.3 mm2) / 3.3 [maximum] 90 [400] Output 20 AWG (0.5 mm2) / 0.518 [minimum] 30 [133] 2 x 10 AWG (5.3 mm2) / 5.3 110 [490] 2 x 8 AWG (8.4 mm2) / 8.4 [maximum] 90 [400] EQUIVALENT CIRCUIT BLOCK DIAGRAMS
sensata.comCopyright © 2025 Sensata Technologies, Inc. MECHANICAL SPECIFICATIONS (1) Tolerances: ±0.02 in [0.5 mm] All dimensions are in inches [millimeters] SURGE CURRENT INFORMATION
sensata.comCopyright © 2025 Sensata Technologies, Inc. THERMAL DERATE INFORMATION (i) SSR metal base plate acting as heat sink, it must be exposed to free ambient air. ORDERING OPTIONS Example : DC60S3KH-B Not all part number combinations are available. Contact Sensata Technical Support for information on the availability of a specific part number. Series DC60 Control Voltage S: 3.5-32 VDC SA: 90-280 VAC/DC Rated Load Current 3: 3 Amps 5: 5 Amps 7: 7 Amps Termination Blank: Screws & clamps K: Installed standoffs with screws for PC Board mounting (1) Thermal Pad Blank: Not Included H: Included Output Type Blank: Normally Open -B: Normally Closed Required for valid part number For options only and not required for valid part number DC60 S 3 K H -B
sensata.comCopyright © 2025 Sensata Technologies, Inc. ACCESSORIES Recommended Accessories Cover Hardware Kit Heat Sink Part No. Thermal Resistance [°C/W] Lug Terminal Thermal Pad KS101 HK1 HK4 HS501DR HS301 / HS301DR HS251 HS201 / HS201DR HS202 / HS202DR HS172 HS151 / HS151DR HS122 / HS122DR HS103 / HS103DR HS101 HS073 HS072 HS053 HS033 HS023 5.0 3.0 2.5 2.0 2.0 1.7 1.5 1.2 1.0 1.0 0.7 0.7 0.5 0.36 0.25 TRM1 TRM6 HSP-1 HSP-2 GENERAL NOTES (2) All parameters at 25°C unless otherwise specified. (3) Heat sinking required, see derating curves. (4) Maximum turn-on voltage for -B, DC control is 1 VDC. (5) Must turn-off voltage for -B, DC control is 3.5 VDC. (6) Turn-on time for -B version is 300μsec. (7) Turn-off time for -B version is 100μsec. (8) All parameters at 50% power rating and 100% duty cycle (contact Sensata tech support for detailed report). (9) For single surge pulse Tc=25°C; Tj=150°C. For additional information or specific questions, contact Sensata Technical Support. AGENCY APPROVALS & CERTIFICATIONS
- IEC 61000-4-2 Electrostatic Discharge Level 3
- IEC 61000-4-4 Electrically Fast Transients Level 3
- IEC 61000-4-5 Electrical Surges Level 3
- Vibration Resistance: IEC 60068-2-6 : Amplitude Range 10-55 Hz, Displacement 0.75mm
- Shock Resistance: IEC 60068-2-27 : Peak Acceleration 15g, Duration 11msec E116950
+1 (800) 350 2727 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Rev: 02/13/25 ECN 20981 FDE-07-01 Rev. B sensata.com CONTACT USCopyright © 2025 Sensata Technologies, Inc. Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.