- Ratings from 10 A to 100 A @ 100 VDC
- LED Status Indicator
- Relays are easily paralleled for higher-current
applications
- UL Approved, CE Compliant to EN60950-1
- Improved SEMS screw and washer
- Redesigned housing with anti-rotation barriers For Generation 3 datasheet click here
- Mosfet Output
- DC control
- EMC Compliant to Level 3
- Epoxy Free Design
- Optional IP20 Cover
- PWM to 1K Hz PRODUCT SELECTION Control Voltage 10 A 20 A 40 A 60 A 80 A 100 A 4-32 VDC DC100D10 DC100D20 DC100D40 DC100D60 DC100D80 DC100D100 AVAILABLE OPTIONS Not all part number combinations are available. Contact Crydom Technical Support for information on the availability of a specific part number. Required for valid part number For options only and not required for valid part number Series Operating Voltage 100: 1-100 VDC Thermal Pad Blank: Not Included H: Included Control Voltage D: 4-32 VDC Cover Blank: Not Included (IP00) C: Included (IP20) Rated Load Current 10: 10 Amps 20: 20 Amps 40: 40 Amps 60: 60 Amps 80: 80 Amps DC D100 HC40 Termination Blank: Screws & clamps K: Installed standoffs with (1) screws for PC Board mounting (IP00 only) K 100: 100 Amps OUTPUT SPECIFICATIONS (2) Description 100 A60 A20 A Recommended Operating Voltage [Vdc] 1-72 1-72 1-72 Absolute Maximing Rating [Vdc] 100 100 100 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.1 Maximum Load Current [Adc] (1)(3) 20 60 100 Minimum Load Current [mA] (4) 2.5 2.5 2.5 Maximum Surge Current (10msec) [Adc] 91 180 330 Maximum On-State Voltage Drop @ Rated Current [Vdc] 0.24 0.36 0.4 Maximum On-State Resistance [RDS-ON] [m/uni03A9] 12 6 4 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.73 0.45 0.27 Minimum Heat Sink for Rated Current @ 40°C [°C/W] 5 1 0.5
80 A40 A10 A
0.1 0.1 0.1 10 40 80 2.5 2.5 2.5 66 136 220 0.13 0.28 0.40 13 7 5 1.27 0.58 0.34 N/R 2 0.5 Maximum Pulse Width Modulation Frequency [Hz] (5) 1000 900 7001000 900 700 INPUT SPECIFICATIONS (2) Description DC Control Control Voltage Range 4-32 VDC Maximum Reverse Voltage -32 VDC Minimum Turn-On Voltage (6) 4 VDC Must Turn-Off Voltage 1 VDC Minimum Input Current (for on-state) 11 mA Maximum Input Current 14 mA Nominal Input Impedance Current Regulated Maximum Turn-On Time [µsec] 75 Maximum Turn-Off Time [µsec] 150 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount
GENERAL SPECIFICATIONS (2) ParametersDescription Dielectric Strength, Input/Output/Base (50/60Hz) 3750 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -40 to 100 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.53 oz (72 g) Housing Material UL94 V-0 Hardware Finish Nickel Plating Baseplate Material Aluminum Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2 Input/Load Terminal Screw Torque Range (in-lb/Nm) (1) w/”K” option 8-10 / 0.9-1.13 SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2 LED Input Status Indicator Green Humidity per IEC60068-2-78 85% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (8) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (8) 11,545,504 hours (1,317 years) Recommended Wire Sizes Terminals Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Input Output 24 AWG (0.2 mm 2) / 0.2 [minimum] 2 x 12 AWG (3.3 mm 2) / 3.3 [maximum] 20 AWG (0.5 mm 2) / 0.518 [minimum] 2 x 10 AWG (5.3 mm 2) / 5.3 2 x 8 AWG (8.4 mm 2) / 8.4 [maximum] 10 [44.5] 90 [400] 30 [133] 110 [490] 90 [400] WIRING DIAGRAM S OLI D S T AT E R ELA Y OUTPUT INPUT Load V V S OLI D S T AT E R ELA Y OUTPUT INPUT V V Load * Inductive loads must be diode suppresed. * * EQUIVALENT CIRCUIT BLOCK DIAGRAMS 0 5 10 15 20 25 30 35 Input Current vs Input Voltage Standard Regulated DC Input Input Current (mA) DC Input Voltage -DC +DC -DC Trigger Circuit Control Circuit +DC Current Limiter INPUT OUTPUT Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC
MECHANICAL SPECIFICATIONS (2) (1) Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination
1 OUTPUT +2
4 INPUT +3
1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 0.89 [22.6] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 1.0 [25.4] 1.75 [44.5] Hex Standoff Termination (“K” Option) 1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 1.04 [26.4] (4 places) 0.93 [23.6] 1.0 [25.4] (2 places) (2 places) Mounting Hole/Slot 0.19 [4.9] DIA. 2.25 [57.3] 1.1 [27.9] 0.49 [12.4] 1.88 [47.6] 1.7 [43.2] 2.32 [58.8] 1.0 [25.4] 1.75 [44.5] 1.0 [25.4] 1.75 [44.5] 1.22 [30.9] Screw Termination, IP20 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount GENERAL NOTES GENERAL NOTES For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support. (2) All parameters at Tc=25°C unless otherwise specified. (3) Heat sinking required, see derating curves. (4) Low current loads and high ambient temperature can affect turn-on time. (5) 8VDC minimum control voltage. Resistive loads only. Consider switching losses; at maximum frequency reduce to 75% output current. (6) Increase minimum voltage by 1V for operations from -20 to -40°C. (7) Decrease maximum control voltage 1.35V/°C above 80°C ambient temperature. (8) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). For additional information or specific questions, contact Crydom Technical Support.
Duty Factor 10% Duty Factor 20% Duty Factor 50% Period Pulse Width For Pulse Width Modulation applications select the curve according duty factor and pulse duration as following. (i) for Single Surge Pulse Tc=40°C ;Tj 175°C (ii) for Repetitive Surge Pulse Tc=40°C ;Tj 130°C Duty Factor = Pulse Width Period x100 (%) Single Pulse (i) Duty Factor (10%) (ii) Duty Factor (20%) (ii) Duty Factor (50%) (ii) 100 0.1 1 10 100 1000 Surge Current (Amp) Surge Duration (msec) DC100D10 100 125 0.1 1 10 100 1000 Surge Current (Amp) Surge Duration (msec) DC100D20 100 150 200 250 300 0.1 1 10 100 1000 Surge Current (Amp) Surge Duration (msec) DC100D40 100 150 200 250 300 350 0.1 1 10 100 1000 Surge Current (Amp) Surge Duration (msec) DC100D60 100 150 200 250 300 350 400 450 500 550 600 0.1 1 10 100 1000 Surge Current (Amp) Surge Duration (msec) DC100D80 200 400 600 800 0.1 1 10 100 1000 Surge Current (Amp) Surge Duration (msec) DC100D100 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount
THERMAL DERATE INFORMATION (iii) SSR metal base plate acting as heat sink, it must be exposed to free ambient air. 20 30 40 50 60 70 80 90 100 2°C/W 3°C/W 5°C/W DC100D40 Load Current (Amps) Ambient Temperature °C 20 30 40 50 60 70 80 90 100 5°C/W No Heat Sink (iii) DC100D20 Load Current (Amps) Ambient Temperature °C 20 30 40 50 60 70 80 90 100 5°C/W No Heat Sink (iii) DC100D10 Load Current (Amps) Ambient Temperature °C 20 30 40 50 60 70 80 90 100 Load Current (Amps) Ambient Temperature °C 1°C/W 2°C/W 5°C/W DC100D60 Load Current (Amps) Ambient Temperature °C 20 30 40 50 60 70 80 90 100 0.5°C/W 1.5°C/W 3°C/W 5°C/W DC100D80 Load Current (Amps) Ambient Temperature °C 100 20 30 40 50 60 70 80 90 100 DC100D100 0.5°C/W 1.5°C/W 3°C/W 5°C/W Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount
IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 E116950 Part number: KS101 Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment. Protective Cover Hardware Kit Part number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. New Accessories! Protective Cover & Hardware Kits Recommended Accessories Cover Hardware Kit Heat Sink Part No. Thermal Resistance [ºC/W] Lug Terminal Thermal Pad KS101 HK1 HK4 HS501DR HS301 / HS301DR HS251 HS201 / HS201DR HS202 / HS202DR HS172 HS151 / HS151DR HS122 / HS122DR HS103 / HS103DR HS101 HS073 HS072 HS053 HS033 HS023 5.0 3.0 2.5 2.0 2.0 1.7 1.5 1.2 1.0 1.0 0.7 0.7 0.5 0.36 0.25 TRM1 TRM6 HSP-1 HSP-2 ACCESORIES Rev. 051216 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
- Disconnect all power before installing or working with this equipment.
- Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
- Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
- Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
- Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
- Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
- Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
- Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
- Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
- Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie 存在电击、 爆炸或电弧 闪烁危险
- 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product's side panels may be hot, allow the product to cool before touching.
- Follow proper mounting instructions including torque values.
- Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
- Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
- Respecter les consignes de montage, et notamment les couples de serrage.
- Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
- Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
- Beachten Sie die Montageanweisungen,
- Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
- Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
- Respetar las instrucciones de montaje, y en particular los pares de apretado.
- No dejar que penetren líquidos o cuerpos extraños en el producto. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
- I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
- Seguire le istruzioni di montaggio corrette.
- Non far entrare liquidi o oggetti estranei in questo apparecchio. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
- 产品的一侧面板可能很热,在其冷却前请 不要触碰。
- 遵照正确的安装说明,包括扭矩值。
- 请勿让液体及其他异物进入本产品。 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount
ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount