DATALOGGERS CAMPBELL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 8

Technical content

More info: +44(0) 1509 828 888 Dataloggers Also known as Data Loggers, Data Recorders, and RTUs www.campbellsci.eu/dataloggers

Campbell Scientific Datalogger Overview Communication Protocols PakBus® With the PakBus protocol, networks have the distributed routing intelligence to continually evaluate links. Continually evaluating links optimizes delivery times and, in the case of delivery failure, allows automatic switch over to a configured backup route. Modbus The Modbus RTU protocol supports both floating point and long formats. The datalogger can act as a slave and/or master. DNP3 The dataloggers are level 2 slave compliant, with some of the operations found in a level 3 implementation. TCP/IP , FTP , and SMTP These protocols provide TCP/IP functionality on the CR6 or CR1000X or, when a CR3000 is used in conjunction with an NL116, NL121, or third party serial IP device. Campbell Scientific dataloggers are at the center of our rugged, reliable data acquisition systems. They are known for their flexibil- ity, precision measurements, and dependability—even in harsh, remote environments. As for functionality, all of our dataloggers: Measure sensors Process data onboard Initiate measurement and control functions based on time or event Store data in multiple tables that can be individually sized and collected Control external devices such as pumps, motors, alarms, freezers, and valves Operate independently of ac power, computers, and human interaction Use our PC support software to program the datalogger Consume minimal power from a 12 Vdc source Interface with on-site and telemetry devices Perform reliably under adverse conditions We manufacture a complete line of dataloggers that range in size and complexity. Dataloggers vary in the supported scan rates, number and type of input/output channels, analog resolution, and analog voltage accuracy. All of our dataloggers have a three year warranty. To help customers choose the best datalogger for their applica- tion, this document describes the different components of the datalogger, provides a brief summary of each datalogger model available, and includes charts that compare the datalogger speci- fications and list the compatible devices. Our family of contemporary dataloggers are programmed us- ing Short Cut, a simple point-and-click software, for most basic applications. For more complex programming, CRBasic provides special instruction for making measurements and creating tables of output data. CRBasic also supports complex algebraic and conditional expressions. Programming Keyboard Display The datalogger’s keypad display which allows you to display cur- rent and recorded data and manually communicate with the dat- alogger. It consists of a 128-by-64 pixel backlit graphical LCD or with-line numeric display and 16-character keyboard. The CR850 and CR3000 have a built-in keyboard display as part of their integrated package. The CR6, CR800, and CR1000X use the CR1000KD, a portable keyboard display that can be carried from site to site. The CR300-series datalogger does not have a keyboard display.

For differential, single-ended, and period averaging measurements

5 V Terminal

For direct connection to PC CPI Port For terminal expansion using Campbell Distributed Modules (CDMs) (CR6 and CR1000X only) Switched 12 V Terminal For switching power to sensors or communication devices

12 V Terminal

Switched Excitation Outputs Provides programmable excitation for resistive bridge measurements Digital I/O Ports For controlling external devices, reading SDI-12 sensors or SDM peripherals CS I/O Port For connecting to Campbell Scientific peripherals Pulse Counters For measuring switch closures, low-level ac sine waves, or high frequency pulses Removable Power Terminal Simplifies connection to external power supply. Analog Inputs Analog inputs measure voltage levels, and can be configured to make single-ended (a voltage measurement compared to ground) or differential (the high side of a voltage output compared to the low side) measurements. Sensors measured by analog inputs in- clude thermocouples, thermistors, resistive bridges, vibrating wire, and 4 to 20 mA outputs. The CR300-series and CR1000X datalog- gers can measure the 4 to 20 mA sensors, natively. Continuous Analog Outputs Some datalogger models have continuous analog outputs, which provide voltage levels to displays or proportional controllers. Pulse Counters Pulse counters measure switch closures, low level ac sine waves, or high frequency pulses. They sum the number of counts over each execution interval (scan rate), and allow the determination of variables such as rpm, velocity, flow, and rainfall intensity. Sen- sors that use pulse counters include tipping bucket rain gauges, fl ow meters, and anemometers. Digital I/O Ports Digital I/O ports detect status, read SDM peripherals or SDI-12 sensors, and control external devices. Each port can be config- ured separately within the datalogger’s program. CPI Port Our CR6 and CR1000X dataloggers have a port for directly con- necting Campbell Distributed Modules (CDMs) without using an SC-CPI interface. Power and Ground Inputs Power and ground inputs allow easy connection of an energy source, typically 12 Vdc nominal, to energize the datalogger. Switched 12 V terminals allow the datalogger to supply power to a peripheral only when the peripheral is being measured, thus reducing power consumption. Switched Excitation Outputs All of our dataloggers have switched voltage excitation outputs. These outputs provide programmable excitations for resistive bridge measurements by switching voltage on and off. Bridge measurements are the ratio of the bridge output to the excita- tion voltage, eliminating any errors in the excitation voltage. The CR3000 and CR6 also have switched current excitation outputs that are for resistance measurements. Communications/Data Storage Ports The CS I/O 9-pin port is used to connect most of our data storage and retrieval peripherals. Connection to a laptop or PC requires an interface, typically the SC32B Optically Isolated Interface. The USB and/or RS-232 port allows the datalogger to be connected to the PC. On the CR300-series, CR3000, and CR9000X, the RS-232 port is electrically isolated. Isolation is not provided by the RS-232 port on the CR800-series dataloggers. Other communication ports available on some dataloggers include the 10/100 Ethernet port, microSD card slot, and 20-pin parallel peripheral port. The peripheral port allows connection of devices that store data on a CompactFlash card and/or commu- nicate via Ethernet. Input/Output Connections

The input channel configuration of the CR300-series datalogger is optimal for measuring two or three sensors. The CR300-series datalogger has an integrated dc/dc charge regulator for an external battery. Design Features: These research-grade dataloggers have a cus- tom ASIC chip that expands pulse count, control port, and serial communications capabilities. They are compatible with channel expansion peripherals and thermocouples, and support serial com- munications with serial sensors and devices via I/O port pairs. Ideal Applications: Wind profiling, weather stations, air quality, ETo/agriculture, soil moisture, water level/stage, aquaculture, vehicle testing, Time Domain Reflectometry, SCADA, water quality. Models Available: CR800 uses the portable CR1000KD keyboard dis- play; CR850 has a keyboard display as part of its integrated package. CR800-series Measurement and Control Datalogger The CR800 series consists of measurement electronics encased in a plastic shell and an integrated wiring panel. The CR800 series uses an external power supply—typically the BPALK Alkaline Battery Pack or PS200 or PS150 Rechargeable Power Supply. Design Features: This is our smallest and lowest-cost datalogger. It has a built-in USB port and can measure 0-to-20 mA or 4-to-20 mA sensors, natively. Ideal Applications: Rural water, aquaculture, water quality, water level/stage, SCADA, weather stations, and OEM application specific where the small form factor and channel count customized to reduce cost Models Available: Unlike the CR300, the CR310 (picture not shown) includes a built-in Ethernet port and removable terminal strips. Options Available: both models can include on-board Wi-Fi,

900 MHz Spread Spectrum Radio, 922 MHz Spread Spectrum Radio,

868 MHz SRD860 radio, or 3G GSM cellular modem. Datalogger Descriptions CR6 Measurement and Control Datalogger Innovative U terminals featuring high accuracy analog measurements with unsurpassed sensor interface flexibility define the CR6. It also boasts fast processing, low power, and offers an integrated charger regulator. Design Features: The CR6 includes 12 universal (U) terminals—an ingenious way for allowing virtually any sensor, analog digital or smart, to be connected to any U terminal. It is our only datalogger capable of doing direct static vibrating-wire measurements. The CR6 also provides faster communications, built-in USB and 10/100baseT ports, microSD card slot, compact size, and improved analog input accuracy and resolution. Measurement and control can be expanded as the CR6 is compatible with all Campbell Scientific SDMs and CDMs. Ideal Applications: Structural health monitoring, solar and wind assessment and power performance, SCADA, vehicle testing, Mesonet systems, weather stations, air quality, ETo/ agriculture, soil moisture, eddy covariance, aquaculture, avalanche forecasting, water quality. Options Available: can include on-board Wi-Fi, 900 MHz spread spectrum radio, 920 MHz spread spectrum radio, 868 MHz SRD860 radio, or 1 W 900 MHz spread spectrum radio.

Design Features: The CR3000 provides more channels, program- mable switched current outputs, and a 40-pin parallel peripheral port. The peripheral port interfaces with the NL116 Ethernet Inter- face and CompactFlash® Module, the NL121 Ethernet Interface, or the CFM100 CompactFlash Module. Ideal Applications: Eddy covariance, wind profiling, HVAC, weather stations, vehicle testing, air quality, process control, Mesonet systems, agriculture, soil moisture, Time Domain Reflectometry, water quality. Base Options: Sealed rechargeable battery or low-profile (no- battery) base. CR3000 Micrologger The CR3000 consists of a compact, integrated package with a built-in power supply, a 128 x 64 pixel backlit graphical or eight-line numeric display, and a 16-character keyboard. Design Features: The CR9000X supports a measurement rate of up to 100,000 Hz, provides 180 MHz clock speed, has an onboard PC-card slot for expanding its storage capacity, and includes an onboard 10baseT/100baseT port. Also, the CR9000X can provide anti-aliasing and real-time FFT capabilities by using a CR9052IEPE or CR9052DC module. Ideal Applications: Vehicle testing, structural or seismic monitor- ing, or other applications that require rapid sampling or a large number of high resolution channels. Base Options: Standard CR9000X includes the base system and slots for up to nine I/O modules; the user chooses either the lab or environmental enclosure. The CR9000XC includes the base system, slots for up to five I/O modules, and an environmental enclosure. CR9000X Measurement and Control Datalogger The CR9000X is a large modular datalogger that consists of a base system and slots for user-specified I/O modules. Design Features: This world-class environmental datalogger has similar communication speed, analog input accuracy, and resolution as the CR6. The CR1000X includes built-in USB and 10/100baseT ports and a microSD card slot. It measures 0-to-20 mA or 4-to-20 mA sensors, natively. Measurement and control can be expanded as the CR1000X is compatible with all Campbell Scientific multiplexers, SDMs, and CDMs. An RS-232/CPI port allows CDM connection without using the SC-CPI interface. Ideal Applications: Fire weather, mesonet systems, wind profiling, weather stations, air quality, ETo/agriculture, soil moisture, water level/stage, aquaculture, avalanche forecasting, Time Domain Re flectometry, vehicle testing, SCADA, water quality. CR1000X Measurement and Control Datalogger The CR1000X is our flagship datalogger that provides measurement and control for a wide variety of applications. It uses an external power supply, usually the BPALK, PS200, or PS150, and a portable keyboard display, the CR1000KD.

FEATURE CR300-Series CR800/CR850 CR6 (see note 1) Max. Scan Rate (Hz) 10 100 1000 Analog Inputs 6 SE or 3 diff (see note 2) 6 SE or 3 diff up to 12 SE or 6 diff Pulse Counters 2 2 up to 16 Switched Excitation Channels 2 voltage 2 voltage up to 12 voltage or 12 current Digital Ports (see notes 3, 4) 2 I/Os

1 TX/RX pair RS-232

4 I/Os or

2 TX/RX pair RS-232

up to 16 I/Os, 2 RS-232, 2 RS-485,

8 TX/RX pair RS-232, or 8 SDI-12

Continuous Analog Outputs 0 0 0 Communications/ Data Storage Ports

1 RS-232, 1 USB,

1 10/100baseT (CR310 only)

1 CS I/O, 1 RS-232 1 USB, 1 CS I/O, 1 CPI/RS-232,

1 MicroSD, 1 10/100baseT

Input Voltage Range (Vdc) -0.1 to +2.5 ±5 ±5 Analog Voltage Accuracy ±(0.04% of reading + offset), 0° to +40°C ±(0.06% of reading + offset), 0° to +40°C ±(0.04% of reading +offset), 0° to +40°C Analog Resolution to 0.23 µV to 0.33 µV to 0.05 μV A/D Bits 24 13 24 Temperature Range (°C) -40 to +70 -25 to +50 (standard) -55 to +85 (extended, CR800) -30 to +80 (extended, CR850) -40 to +70 (standard) -55 to +85 (extended) Memory (B) 10 M flash for data storage

5 M flash for CPU drive / programs

2 M flash for operating system

2 M Flash (operating system)

4 M (CPU usage, program

storage, and data storage)

6 M flash (operating system),

6 M (CPU usage, program,

storage, and data storage) Power Requirements (Vdc) 16 to 32 CHS, 9.6 to 16 BAT 9.6 to 16 16 to 32 CHS, 9.6 to 16 BAT Typical Current Drain (mA) 1.5 (sleep, no radio) 5 (active, 1 Hz scan with analog measurement, no radio) ~0.7 (sleep mode) 1 to 16 (w/o RS-232 comm) 17 to 28 (w/RS-232 comm) ~0.8 (sleep mode) 3 (1 Hz sample rate), 67 (20 Hz sample rate) Weight (lb) 0.5 (CR300) 0.6 (CR310, CR300-WIFI/RF407/412/422) 0.7 (CR310-WIFI/RF407/412/422) 1.5 0.9 (CR6) 1.0 ( CR6-WIFI//RF407/412/422/451) SDI-12 Supported yes yes yes PakBus Supported yes yes yes Modbus Supported yes yes yes DNP3 Supported yes yes yes Compliance Information Available at: www.campbellsci.eu/cr300 www.campbellsci.eu/cr310 Available at: www.campbellsci.eu /cr800 www.campbellsci.eu/cr850 Available at: www.campbellsci.eu /cr6 SOFTWARE SUPPORTED Short Cut 3.2 or higher yes yes PC200W 4.4 or higher yes yes PC400 4.4 or higher 1.2 or higher 4.3 or higher LoggerNet 4.4 or higher 3.0 or higher 4.3 or higher RTDAQ no yes yes Notes: 1. The CR6 has 12 universal (U) and four control (C) terminals that can be programmed for a variety of functions. The number of analog inputs, switched excitations, and digital ports assume all of the ports are configured the same. 2. On the CR300-series, two analog inputs can measure 4 to 20 mA or 0 to 20 mA, natively, and four analog inputs can provide pulse/digital I/O functions. 3. Certain digital ports can be used to count switch closures. 4. I/O ports can be paired as transmit and receive for measuring smart serial sensors. 5. We recommend you confirm system configuration and critical specifications with Campbell Scientific before purchase. Datalogger Comparison Table

FEATURE CR1000X CR3000 CR9000X (see note 1) Max. Scan Rate (Hz) 1000 100 100,000 Analog Inputs 16 SE or 8 diff (see note 2) 28 SE or 14 diff 28 SE or 14 diff per CR9050, CR9051E, or CR9055(E) Pulse Counters 2 4 12 per CR9071 Switched Excitation Channels 4 voltage 4 voltage, 3 current 10 voltage per CR9060 Digital Ports (see note 3,4) 8 I/Os, 4 TX/RX pair RS-232, or 4 SDI-12

3 SDM, 8 I/Os or

4 TX/RX pair RS-232

or 16 I/Os per CR9071; 1 SDM Continuous Analog Outputs 0 2 6 per CR9060 Communications/ Data Storage Ports

1 USB, 1 CS I/O, 1 CPI/RS-232,

1 CS I/O, 1 RS-232

1 CS I/O, 1 RS-232, 1 10/100baseT

Input Voltage Range (Vdc) ±5 ±5 ±5 w/CR9050 or CR9051E, ±50 w/CR9055(E), ±60 w/CR9058E Analog Voltage Accuracy ±(0.04% of reading +offset), 0° to +40°C ±(0.04% of reading +offset), 0° to +40°C ±(0.07% of reading+4 A/D counts), -25° to +50°C Analog Resolution to 0.05 μV to 0.33 μV to 1.6 μV A/D Bits 24 16 16 Temperature Range (°C) -40 to +70 (standard) -55 to +85 (extended) -25 to +50 (standard) -40 to +85 (extended) -25 to +50 (standard) -40 to +70 (extended) Memory (bytes) 128 MB Flash + 4 MB SRAM (battery backed)

2 M Flash (operating system),

4 M (CPU usage, program,

storage, and data storage) 128 k (program),

128 M (data storage)

Power Requirements (Vdc) 10 to 16 10 to 16 9.6 to 16 Typical Current Drain (mA) <1 (idle) 1 (1 Hz sample rate), 55 (20 Hz sample rate) 2 (sleep mode), 3 (1 Hz sample rate), 10 (20 Hz sample rate) 750 to 1000 (processing), 750 to 4000 (analog meas.) 18 x 13.5 x 9 (field enclosure), 10 x 11 x 9 (CR9000XC) Weight (lb) 1.9 10.7 (rechargeable battery), 3.6 (w/o battery) ~30 (lab enclosure), ~40 (field enclosure), ~27 (CR9000XC) SDI-12 Supported yes yes no PakBus Supported yes yes no Modbus Supported yes yes no DNP3 Supported yes yes no Compliance Information Available at: www.campbellsci.eu/cr1000x Available at: www.campbellsci.eu /cr3000 CE compliant SOFTWARE SUPPORTED Short Cut yes yes no PC200W yes yes no PC400 4.5 or higher 1.3 or higher 1.0 or higher LoggerNet 4.5 or higher 3.2 or higher 2.0 or higher RTDAQ yes yes yes Notes: 1. For the CR9000X, the current drain, weights, and specific number of input/output channels depend on the I/O modules chosen 2. On the CR1000X, two analog inputs can measure 4 to 20 mA or 0 to 20 mA, natively, and four analog inputs can provide pulse/digital I/O functions.. 3. Certain digital ports can be used to count switch closures. 4. For the CR1000X and CR3000, the I/O ports can be paired as transmit and receive for measuring smart serial sensors. 5. We recommend you confirm system configuration and critical specifications with Campbell Scientific before purchase. Datalogger Comparison Table Continued

© 1999, 2017 Campbell Scientific January 4, 2018 80 Hathern Road, Shepshed, LE12 9GX UK | +(0)1509 828888 | sales@campbellsci.co.uk | www.campbellsci.eu U K | AUSTRALIA | BRAZIL | CANADA | CHINA | COSTA RICA | FRANCE | GERMANY | SE ASIA | SOUTH AFRICA | SPAIN | USA Sensor and Peripheral Compatibility Table DEVICE CR300-Series CR800/CR850 CR6 CR1000X CR3000 CR9000X SENSORS Anemometers (cup or propeller)       Anemometers (2-D sonic)      Anemometers (3-D sonic)       Vibrating wire     COMMUNICATIONS PERIPHERALS MicroSD   CompactFlash®   Multidrop Modems      PCMCIA Cards (type I, II, or III)  Phone Modems (cellular)      see note 3 Phone Modems (land-line)     see note 3 Radios (narrowband UHF/VHF)      Radios (spread spectrum/SRD860)      see note 3 Satellite Transmitters (GOES)      Satellite Transmitters (Argos)      Satellite Transmitters (Iridium)      Short-Haul Modems     see note 3 MEASUREMENT AND CONTROL PERIPHERALS (see note 4) Multiplexers see note 5      CDM Devices (see note 6)     Notes: 1. To determine compatibility with devices not offered by Campbell Scientific or devices not listed on this chart, refer to the device’s product brochure or manual, or contact Campbell Scientific. 2. Contact Campbell Scientific about configuration requirements for using the CR9000X with our GPS sensor. 3. Although compatible, phone modems, spread spectrum radios, and short haul modems do not support the CR9000X’s maximum communication rate. 4. Measurement and control devices typically used with the CR9000X are the AM25T and SDM-CAN. Although compatible, the AM16/32B, SDM-CD16AC, and SDM-CVO4 do not support the CR9000X’s maximum communication rate and are not practical for most CR9000X applications. 5. The CR300-series dataloggers are compatible with the AM25T only and the datalogger must have OS version 6 or later. 6. Our CR6 and CR1000X dataloggers support CDMs natively through their CPI port. The CR800, CR850, and CR3000 must use an SC-CPI interface.