Power Entry Modules with Line Filter DA22 www.schurter.com/pg06 EMC Products IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, for PCB Mounting Standard- or Medical-Filter and -Fuse drawer C14 70° C
Description
- Panel Mount: Screw-on mounting on PCB, from rear-side - 3 Functions: Appliance Inlet, Fuseholder for fuse-links 5 x 20 mm, Line filter in stan - dard and medical version - PCB solder terminals - Alternative: version for panel mounting KFA Approvals - VDE License Number: 40001522 - UL License Number: E72928 Characteristics - Ultra-compact design - All single elements are already wired - For added safety "Extra-Safe" fuse drawers are available Fuse drawer meets requirements of medical standard IEC/EN 60601-1 The fuseholder is accessible from the equipment front - Qualified for use in equipment according IEC/EN 60950 Other versions on request - Fixing on PCB with self-tapping screws 3 mm or pre-inserted nuts M3 - Fuse drawer 1-pole, plus spare fuse case - Fuse drawer 2-pole, with shorting bar - Medical version M80, 220 nF X capacitors - Class X1- and Y1-capacitors for enhanced withstand voltage - Protection class II, 70°C References General Product Information Weblinks Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories T echnical Data Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz Ratings UL/CSA 1 - 10 A @ Ta 40 °C / 125/250 VAC; 50/60 Hz ¹⁾ Leakage Current standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) Dielectric Strength > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (1 min/50 Hz) Allowable Operation Temp. -25 °C to 85 °C Climatic Category 25/085/21 acc. to IEC 60068-1 Degree of Protection from front side IP 40 acc. to IEC 60529 Protection Class Suitable for appliances with protection class 1 acc. to IEC 61140 Terminal For PCB mounting ; Additional for ground terminal: Quick connect termi nals 6.3 x 0.8 mm angled to pin axis Panel Thickness s Screw-on mounting: max 3 mm Mounting screw torque max 0.5 Nm Material: Housing Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet C14 acc. to IEC/EN 60320-1 UL 498 CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 Fuseholder 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm Rated Power Acceptance @ Ta 23 °C 5 x 20: 2 W (1 pole)/ 1.4 W (2-pole) per pole Power Acceptance @ Ta > 23°C Admissible power acceptance at hig- her ambient temperature see derating curves Line Filter Standard and Medical Version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details MTBF > 2'000'000 h acc. to MIL-HB-217 F 1) UL appovals: 1-pole versions up to 10 A, 2-pole versions up to 8 A
Power Entry Modules with Line FilterDA22 www.schurter.com/pg06 EMC Products Dimensions 57.6 mm 34.4 ±0.10R 4.2 ±0.05 3.6 46.8 57.6 2.2 47.65.8 4.2 R 5.1 R 4 64.5 19.5 3.4 342.5 37.6 36.1 32.5 8.1 1.25 32.7 0.85 47.05 30.4 16.2 2.8 4 10.5 ±0.10 ±0.15 32.7±0.20 1.6+0.1 0 0 ±0.10 6.05 3.6 1.6+0.1 0 0 1.6+0.1 0 038±0.20 16.2±0.15 6.6 6.3x0.8 3.4 R 4.4 T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version with Bleed Resistor 2 x 10 100 2.2 1 2 Standard Version with Bleed Resistor 2 x 4 100 2.2 1 4 Standard Version with Bleed Resistor 2 x 1.5 100 2.2 1 6 Standard Version with Bleed Resistor 2 x 0.8 100 2.2 1 8 Standard Version with Bleed Resistor 2 x 0.6 100 2.2 1 10 Standard Version with Bleed Resistor 2 x 0.3 100 2.2 1
1 Medical Version (M5) 2 x 10 100 - 1
2 Medical Version (M5) 2 x 4 100 - 1
4 Medical Version (M5) 2 x 1.5 100 - 1 6 Medical Version (M5) 2 x 0.8 100 - 1 8 Medical Version (M5) 2 x 0.6 100 - 1 10 Medical Version (M5) 2 x 0.3 100 - 1 Diagrams Standard version with bleed resistor and Medical version M80 1-/2-pole L PE N Cx Cy Cy PE’ R PE’’ 1) 2) 1) Line 2) Load Medical version M5 1-/2-pole L PE N Cx PE’ R PE’’ 1) 2) 1) Line 2) Load
Power Entry Modules with Line Filter DA22 www.schurter.com/pg06 EMC Products Derating Curves 1-poleAdmissible power ac- ceptance in Watt 0 2 0 4 0 6 0 8 0 100 I = << In I = 0.7 In I = 1.0 In 2.0 1.5 1.0 0.5 0.0 Ambient air temperature Ta °C 2-poleAdmissible power ac- ceptance in Watt per pole0 2 0 4 0 6 0 8 0 100 0.2 0.0 I = << In I = 0.7 In I = 1.0 In 1.4 0.6 0.4 1.0 0.8 1.2 Ambient air temperature Ta °C Attenuation Loss - - - - differential mode _____ common mode Standard version 1 A 2 A 4 A 6 A 8 A 10 A Medical version (M5) 1 A 2 A 4 A 6 A 8 A 10 A T echnical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version with Bleed Resistor 2 x 10 100 2.2 1 2 Standard Version with Bleed Resistor 2 x 4 100 2.2 1 4 Standard Version with Bleed Resistor 2 x 1.5 100 2.2 1 6 Standard Version with Bleed Resistor 2 x 0.8 100 2.2 1 8 Standard Version with Bleed Resistor 2 x 0.6 100 2.2 1 10 Standard Version with Bleed Resistor 2 x 0.3 100 2.2 1 4 Medical Version (M5) 2 x 1.5 100 - 1 6 Medical Version (M5) 2 x 0.8 100 - 1 8 Medical Version (M5) 2 x 0.6 100 - 1 10 Medical Version (M5) 2 x 0.3 100 - 1
Power Entry Modules with Line FilterDA22 www.schurter.com/pg06 EMC Products Variants Rated Current [A] Filter-Type Fuseholder Comment Order Number 1 Standard Version with Bleed Resistor 1-pole - DA22.1111.11 2 Standard Version with Bleed Resistor 1-pole - DA22.2111.11 4 Standard Version with Bleed Resistor 1-pole - DA22.4111.11 6 Standard Version with Bleed Resistor 1-pole - DA22.6111.11 8 Standard Version with Bleed Resistor 1-pole - DA22.8111.11 10 Standard Version with Bleed Resistor 1-pole 1) DA22.9111.11 1 Standard Version with Bleed Resistor 2-pole - DA22.1121.11 2 Standard Version with Bleed Resistor 2-pole - DA22.2121.11 4 Standard Version with Bleed Resistor 2-pole - DA22.4121.11 6 Standard Version with Bleed Resistor 2-pole - DA22.6121.11 8 Standard Version with Bleed Resistor 2-pole - DA22.8121.11 10 Standard Version with Bleed Resistor 2-pole 1) DA22.9121.11 1 Medical Version (M5) 2-pole - DA22.1321.11 2 Medical Version (M5) 2-pole - DA22.2321.11 4 Medical Version (M5) 2-pole - DA22.4321.11 6 Medical Version (M5) 2-pole - DA22.6321.11 8 Medical Version (M5) 2-pole - DA22.8321.11 10 Medical Version (M5) 2-pole 1) DA22.9321.11 1) UL approvals: versions with 1-pole fuseholder are approved up to 10 A, 2-pole versions up to 8 A. Packaging unit 20 Pcs Required Accessory Fusedrawer with and without Voltage Selector Insert Fingergrip, 2-pole 4301.1401 Extra-Safe, 2-pole 4301.1403 Fingergrip, 1-pole 4301.1405 Extra-Safe, 1-pole 4301.1407 ... Accessories Cord retaining kits Cord retaining strain relief Flat head, H 4700.0008 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal 5092 Appliance Outlet further types to DA22
Power Entry Modules with Line Filter DA22 www.schurter.com/pg06 EMC Products Connector Overview complete IEC Connector C15, Rewireable, Straight 0101 IEC Connector C15A, Rewireable, Straight 0102 IEC Connector C15A, Rewireable, Straight 0102-G IEC Connector C15A, Rewireable, Angled 0112 IEC Connector C13, Rewireable, Angled 4012 Connector further types to DA22 ... Power Cord Overview complete Power Cord with IEC Connector C13, Angled 0311 Power Cord with IEC Connector C13, Angled 3011 Power Cord with IEC Connector C13, Angled 3012 Power Cord with IEC Connector C13, Angled 3013 Power Cord with IEC Connector C13 3020 Power Cord further types to DA22 ... The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments.