1-DC SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 7

Technical content

Features

  • Ratings from 7 A to 40 A @ 200 VDC and from 7 A to 10 A @ 500VDC
  • Mosfet Output
  • UL Approved, CE Compliant to EN60950-1
  • Improved SEMS screw and washer
  • Redesigned housing with anti-rotation barriers
  • DC control
  • EMC Compliant to Level 3
  • Epoxy Free Design Load Voltage 7 A 10 A 12 A 20 A 40 A

100 VDC D1D07 D1D12 D1D20 D1D40

200 VDC D2D07 D2D12 D2D40

400 VDC D4D07 D4D12

500 VDC D5D07 D5D10

Description 7 A 12 A 20 A 40A 7A 12A 40A 7A 12A 7A 10A Recommended Operating Voltage [Vdc] 1-72 1-72 1-72 1-72 1-150 1-150 1-150 1-300 1-300 1-385 1-385 Absolute Maximum Rating [Vdc] 100 100 100 100 200 200 200 400 400 500 500 Maximum Off-State Leakage Current @ Rated Maximum Load Current Adc 7 12 20 40 7 12 40 7 12 7 10 Minimum Load Current mA 1 1 1 1 1 1 1 1 1 1 1 Maximum Surge Current (10msec) [Adc] 23 28 42 106 22 31 106 18 36 19 29 Maximum On-State Voltage Drop @ Rated Maximum On-State Resistance [RDS-ON] Thermal Resistance Junction to Case (Rjc) Minimum Heat Sink for Rated Current @ 40°C [°C/W] 5 3 2 1 3 3 0.7 2 1 1 0.7 Maximum Pulse Width Modulation Frequency Hz 5000 4000 3500 2500 3500 2000 950 1200 900 1100 900 SPECIFICATIONS Output (2)

www.sensata.com Page 2 Copyright © 2024 Sensata Technologies Inc. Description DC Control Control Voltage Range 3.5-32 VDC Maximum Reverse Voltage -32 VDC Minimum Turn-On Voltage (6) 3.5 VDC Must Turn-Off Voltage 1 VDC Minimum Input Current (for on-state) 10 mA Maximum Input Current 15 mA Nominal Input Impedance Current Regulated Maximum Turn-On Time [µsec] 100 Maximum Turn-Off Time [µsec] 100 Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 3750 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -40 to 100 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.66 oz (75.5 g) Housing Material UL94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range (lb-in/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (lb-in/Nm) 18-20 / 2-2.2 SSR Mounting Screw Torque Range (lb-in/Nm) 18-20 / 2-2.2 Input/Load Terminal Screw Torque Range (lb-in/Nm) (1) w/”K” option 8-10 / 0.9-1.13 Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC Humidity per IEC60068-2-78 93% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (8) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (8) 11,545,504 hours (1,317 years) Input (1) General (1) WIRING DIAGRAM Recommended Wire Sizes Terminals Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Input 24 AWG (0.2 mm2) / 0.2 [minimum] 10 [44.5] 2 x 12 AWG (3.3 mm2) / 3.3 [maximum] 90 [400] Output 20 AWG (0.5 mm2) / 0.518 [minimum] 30 [133] 2 x 10 AWG (5.3 mm2) / 5.3 110 [490] 2 x 8 AWG (8.4 mm2) / 8.4 [maximum] 90 [400] SOLID ST AT E RELA Y OUTPU T INPU T Load V V SOLID ST AT E RELA Y OUTPU T INPU T V V Load * Inductive loads must be diode suppresed. * *

www.sensata.com Page 3 Copyright © 2024 Sensata Technologies Inc. EQUIVALENT CIRCUIT BLOCK DIAGRAMS -DC +DC -DC Trigger Circuit Control Circuit +DC 10 15 20 25 30 35 Input Current vs Input Voltage Standard Regulated “DC” Inputs Input Current (mA) DC Input Voltage 0 5 MECHANICAL SPECIFICATIONS (2) All dimensions are in millimeters [inches] Tolerance:±0.02 in / 0.5 mm SURGE CURRENT INFORMATION

www.sensata.com Page 4 Copyright © 2024 Sensata Technologies Inc. 0.1 11 01 00 1000 Surge Current (Amp) Surge Duration (msec) D2D07 0.11 10 1001 000 Surge Current (Amp) Surge Duration (msec) D2D12 100 120 140 160 180 200 220 240 0.11 10 1001 000 Surge Current (Amp) Surge Duration (msec) D2D40 0.11 10 1001 000 Surge Current (Amp) Surge Duration (msec) D4D07 0.11 10 1001 000 Surge Current (Amp) Surge Duration (msec) D4D12 0.11 10 1001 000 Surge Current (Amp) Surge Duration (msec) D5D07 0.1 11 01 00 1000 Surge Current (Amp) Surge Duration (msec) D5D10 Duty Factor 10% Duty Factor 20% Duty Factor 50% For Pulse Width Modulation applications select the curve according duty factor and pulse duration as following. Duty Factor = Pulse Width Period x100 (%) (i) for Single Surge Pulse Tc=40°C ;Tj 175°C (ii) for Repetitive Surge Pulse Tc=40°C ;Tj 130°C Period Pulse Wide

www.sensata.com Page 5 Copyright © 2024 Sensata Technologies Inc. 20 30 40 50 60 70 80 90 100 Load Current (Amps) Ambient Temperature (ºC) D1D07 5˚C/W No Heat Sink(iii) 20 30 40 50 60 70 80 90 100 D1D12 3˚C/W 5˚C/W No Heat Sink(iii) Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D1D20 2˚C/W 3˚C/W No Heat Sink(iii) Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D1D40 1˚C/W 3˚C/W 5˚C/W Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D2D07 3˚C/W 5˚C/W No Heat Sink(iii) Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D2D12 3˚C/W 5˚C/W No Heat Sink(iii) Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D2D40 0.7˚C/W 1.5˚C/W 5˚C/W Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D4D12 1˚C/W 2˚C/W 5ºC/W Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D4D07 2˚C/W 3˚C/W No Heat Sink(iii) Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D5D07 1˚C/W 3˚C/W 5ºC/W Load Current (Amps) Ambient Temperature (ºC) 20 30 40 50 60 70 80 90 100 D5D10 Load Current (Amps) Ambient Temperature (ºC) 0.7˚C/W 2˚C/W 5˚C/W THERMAL DERATE INFORMATION (iii) SSR metal base plate acting as heat sink, it must be exposed to free ambient air.

www.sensata.com Page 6 Copyright © 2024 Sensata Technologies Inc. ACCESORIES Cover Hardware Kit Lug Terminal Thermal Pad Heat Sink Part No. Thermal Resistance [ºC/W] KS101 HK1 HS501DR 5.0 TRM1 HSP-1 HK4 HS301 / HS301DR 3.0 TRM6 HSP-2 HS251 2.5 HS201 / HS201DR 2.0 HS202 / HS202DR 2.0 HS172 1.7 HS151 / HS151DR 1.5 HS122 / HS122DR 1.2 HS103 / HS103DR 1.0 HS101 1.0 HS073 0.7 HS072 0.7 HS053 0.5 HS033 0.36 HS023 0.25 Recommended Accessories D 1D 07 K Series D: 1-DC Series Operating Voltage 1D: 1-100 VDC 2D: 1-200 VDC 4D: 1-400 VDC 5D: 1-500 VDC Rated Load Current 07: 7 Amps 10: 10 Amps (500 VDC only) 12: 12 Amps (not for 500 VDC) 20: 20 Amps (100 VDC only) 40: 40 Amps (100 & 200 VDC only) Termination Blank: Screws & clamps K: Installed standoffs with screws for PC Board mounting (1) AVAILABLE OPTIONS Example : D1D07K Required for valid part number For options only and not required for valid part number

www.sensata.com CONTACT US Americas +1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2024 Sensata Technologies, Inc. Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Rev. 03/01/2024 ECN 21026 FDE-07-01 Rev. B (2) All parameters at Tc=25°C unless otherwise specified. (3) Heat sinking required, see derating curves. (4) Low current loads and high ambient temperature can affect turn-on time. (5) 8VDC Minimum control voltage. Resistive loads only. Consider switching losses; at maximum frequency reduce to 75% output current. (6) Increase minimum voltage by 1V for operations from -20 to -40°C. (7) Decrease maximum control voltage 1.35V/°C above 80°C ambient temperature. (8) All parameters at 50% power rating and 100% duty cycle. For additional information or specific questions, contact Sensata Technical Support. GENERAL NOTES AGENCY APPROVALS IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 E116950 WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.