D53TP50CH-10 CRYDOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

C: IP20 Load Current/per phase 25: 25 Amps 50: 50 Amps 53TP Series IP20

  • Three-phase solid-state relay; Ratings 25 A, 50 A per phase @ 48-530 VAC
  • 2 package styles IP20 or IP00 (See IP00 spec sheet for more information)
  • SCR output for heavy industrial loads
  • AC or DC control
  • Zero-crossing (resistive loads) or random-fire (inductive loads) output
  • LED input status indicator
  • Transient protection built in PRODUCT SELECTION Control Voltage 50 A 90-140 VAC B53TP50C 80-260 VAC C53TP50C AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description 50 A Operating Voltage (47-63Hz) [Vrms] 48-530 Transient Overvoltage [Vpk] (2) 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 3 Minimum Off-State dv/dt @ Maximum Rated Voltage [V//uni03BCsec] (2) 500 Maximum Load Current [Arms] (3) 50 Minimum Load Current [Arms] 0.1 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 710/750 Maximum 1 Second Surge Current 50/60 Hz [Apk] 150 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.12 Maximum 1/2 Cycle I²t for Fusing (50/60 Hz) [A² sec] 2520/2320 DataSheetPanel Mount 25 A B53TP25C C53TP25C 4-32 VDC D53TP50C 18-36 VAC E53TP50C D53TP25C E53TP25C 25 A 48-530 1200 500 0.1 1.35 0.24 Minimum Power Factor (with Maximum Load) 0.5 UL/IEC 60947 Motor Control Ratings at 120V [HP/KW] (4) 1.5/1.11 UL/IEC 60947 Motor Control Ratings at 240V [HP/KW] (4) 3/2.22 UL/IEC 60947 Motor Control Ratings at 380V [HP/KW] (4) 5/3.7 UL/IEC 60947 Motor Control Ratings at 480V [HP/KW] (4) 7.5/5.55 0.5 0.75/0.56 1/0.74 2/1.48 3/2.22 Series Relay Options Blank: Zero Voltage Turn-On -10: Random Turn-On Control Voltage B: 90-140 VAC C: 180-260 VAC D: 4-32 VDC E: 18-36 VAC D 53 25 Type TP: 3 switched channels TP C Relay Options H: Thermal pad installed H -10 Required for valid part number For options only and not required for valid part number Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice.

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. INPUT SPECIFICATIONS (1) C53D53Description Control Voltage Range 4-32 VDC 180-260 Vrms Minimum Turn-On Voltage 4.0 VDC 180 Minimum Turn-Off Voltage 1.0 VDC 10 Minimum Input Current (for on-state) 24 mA 7.0 mA Maximum Input Current 35 mA 20 mA Nominal Input Impedance Current Regulated Current Regulated Maximum Turn-On Time [msec] (5) 8.33 20 8.33 B53 90-140 VDC 7.0 mA 16 mA Current Regulated 30 30 E53 18-36 VAC 15 mA 20 mA Current Regulated GENERAL SPECIFICATIONS (1)

Description

Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 V DC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation Terminals Screws and Saddle clamps Input Terminal Screw Torque Range:[in lbs/Nm] Output Terminal Screw Torque Range:[in lbs/Nm] Parameters

4000 Vrms

109 Ohms

-40ºC to 80ºC -40ºC to 125ºC 13.1 oz (370g) NA Hardware Furnished, mounted Zinc plated Steel 8-10 / 0.9-1.1 15-20 / 1.7-2.2 GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 3) Heat sinking required, see page 3 for derating curves. 4) At 40°C Ambient temperature. 5) Turn-on time for Random turn-on versions is 0.02 msec (DC Control Models) DataSheetPanel Mount Maximum Turn-Off Time [msec] Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] MECHANICAL SPECIFICATIONS 4.0 [101.3] 3.6 [92.0] 1.5 [38.6] 0.8 [19.3] 0.2 [5.1] 6/T3 4/T2 2/T1 5/L3 3/L2 1/L1 1.45 [36.83] 4.09 [103.9]

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DataSheet AGENCY APPROVALS Rev. 062316 Panel Mount THERMAL DERATE INFORMATION 53TP IP20 25A DERATE CURVES: 3020 40 50 60 70 80 Ambient Temperature [°C] Load Currect Per Channel (Amperes) Agency Approvals Designed in accordance with the requirements of IEC 62314 IEC 62314 IEC 60068-2-6 35mm / 10-55Hz IEC 60068-2-27 15G / 11ms IEC 1000-4-2 : Electrostatic Discharge – Level 3 IEC 1000-4-3 : Radiated Electromagnetic Noise – Level 3 IEC 1000-4-4 : Electrically Fast Transients – Level 3 IEC 1000-4-5 : Electrical Surges – Level 3 IEC 1000-4-6 : Conducted Electromagnetic Noise – Level 3 E79183 2.0˚C/W 1.5˚C/W 1.0˚C/W 0.7˚C/W 0.5˚C/W 53TP IP20 50A DERATE CURVES: 3020 40 50 60 70 80 Ambient Temperature [°C] Load Currect Per Channel (Amperes) 1.5˚C/W 1.0˚C/W 0.7˚C/W 0.5˚C/W 0.2˚C/W

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DataSheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • Disconnect all power before installing or working with this equipment.
  • Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
  • Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
  • Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
  • Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
  • Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
  • Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
  • Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. 存在电击、 爆炸或电弧 闪烁危险
  • 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
  • The product's side panels may be hot, allow the product to cool before touching.
  • Follow proper mounting instructions including torque values.
  • Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
  • Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
  • Respecter les consignes de montage, et notamment les couples de serrage.
  • Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
  • Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
  • Beachten Sie die Montageanweisungen,
  • Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
  • Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
  • Respetar las instrucciones de montaje, y en particular los pares de apretado.
  • No dejar que penetren líquidos o cuerpos extraños en el producto. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
  • 产品的一侧面板可能很热,在其冷却前请 不要触碰。
  • 遵照正确的安装说明,包括扭矩值。
  • 请勿让液体及其他异物进入本产品。 RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
  • Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
  • Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
  • I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
  • Seguire le istruzioni di montaggio corrette.
  • Non far entrare liquidi o oggetti estranei in questo apparecchio. Panel Mount

Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 DataSheetPanel Mount