D53RV25C CRYDOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

  • Three-phase Motor Reversing solid-state relay;
  • Ratings from 25A and 50A per phase @ 48-530 VAC
  • SCR output for heavy industrial loads
  • DC control
  • LED input status indicator PRODUCT SELECTION Control Voltage 25A 50A 4-32 VDC D53RV25C D53RV50C AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description D53RV25C D53RV50C Operating Voltage (47-63Hz) [Vrms] 48-530 48-530 Maximum Load Current (3) [Arms] 25 50 Transient Overvoltage [Vpk] 1100 1100 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 3 3 Minimum Load Current [Arms] 0.1 0.1 Maximum Surge Current 50/60 Hz (16.6ms) [Apk] 475/500 710/750

1 Second Surge Current 50/60 Hz [Apk] 100 150

Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 1.35 Maximum I²T for Fusing (50/60 Hz, 1/2 cycle) [A² sec] 1130/1030 2520/2320 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.26 0.25 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500 HP Ratings at 120V 0.75 1.5 HP Ratings at 240V 1 3 HP Ratings at 480V 3 7.5

INPUT SPECIFICATIONS (1) Description Parameters Control Voltage Range 4-32 VDC Minimum Turn-On Voltage 4.0 VDC Minimum Turn-Off Voltage 1.0 VDC Minimum Input Current (for on-state) 17mA Maximum Input Current 25mA Input Resistance Current Regulated Maximum Turn-On Time [msec] 150 Maximum Turn-Off Time [msec] 1/2 Cycle Interlocking Time [msec] 100 GENERAL SPECIFICATIONS Description Parameters Input to Output Isolation 4000 Vrms Input/ Output to Ground Isolation 2500 Vrms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80°C Ambient Storage Temperature Range -40 to 100 °C Weight (typical) 13.1 oz (370g) Housing Material UL 94V0 (self extinguishing Terminals Screws and Clamps Furnished Input Terminal Screw Torque Range:[in lbs/Nm] 16.8/1.9 Output Terminal Screw Torque Range:[in lbs/Nm] 21.2/2.4 GENERAL NOTES GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 THERMAL DERATE INFORMATION

R e v . 0 1 2 0 1 0

ANNEX - ENVIROMENTAL INFORMATION