D5014 GMI | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
www.gminternational.com FSM SIL 3 Data specified in this document are merely descriptive of the products and should be integrated with relevant technical specifications. Our products are in constant development and the information presented herein refers to the time of document issue. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. Terms & Conditions can be found at our website. For more information refer to instruction manual. Functional Safety Management Certification: GM International is certified to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. In addition, GM International products have been granted I.S. certificates from the most credited Notified Bodies in the world. I.S. SIL3 2/4-Wire HART® Transmitter Power Supply D5014 The Repeater Power Supply D5014 module is a high integrity analog input interface suitable for applications requiring SIL 3 level in safety related systems for high risk industries. It provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA, active or passive, transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The module supports output current duplication and it allows bi-directional communication signals, for HART® devices. Intrinsically Safe Isolators > Analog Input
FEATURES
- SIL 3 / SC 3
- Input from Zone 0/Div. 1
- Installation in Zone 2/Div. 2
- 2 fully independent channels
- 4-20 mA Active-Passive Input, Source-Sink Output
- Output current duplication available
- HART® compatible
- Input and Output short circuit proof
- In-field programmability by DIP Switch
- High Accuracy
- Three port isolation, Input/Output/Supply
- High Density, two channels per unit FUNCTION DIAGRAM = = 5 + 6 -
2 RLmA
Out (SIL 3)Supply 24 Vdc HHT2 Wire Tx I External Powered Tx In MODEL D5014S +- Termination board connector Pow er Bus mA + V Source V Sink I RL = = 5 + 6 - Out 1 (SIL 3)
4 RLmA
Out 2 (SIL 3) HHT HHT2 Wire Tx I External Powered Tx In 1
2 Wire Tx
I MODEL D5014D +- Termination board connectorPower Bus = = Supply 24 Vdc mA + V Source V Sink I RL mA + V Source V Sink I RL Hazardous Area TECHNICAL DATA Supply 24 Vdc nom (18 to 30 Vdc), reverse polarity protected. Current consumption: 90 mA (D5014D), 45 mA (D5014S), @ 24 Vdc with 20 mA output, typical. Power dissipation: 1.35 W (D5014D), 0.68 W (D5014S), @ 24 Vdc with 20 mA output, typical. Input 4 to 20 mA (separately powered input, voltage drop ≤ 0.5 V) or 4 to 20 mA (2 wires Tx current limited ≈ 25 mA), reading range 0 to 24 mA. Transmitter line voltage: 15.0 V typical, 14.5 V minimum, @ 20 mA. Output 4 to 20 mA, on max. 550 Ω load in source mode (typical 12 V compliance); V min. 8 V @ 0 Ω load V max. 30 V in sink mode, current limited ≈ 25 mA or 1 to 5 V on internal 250 Ω shunt (or 2 to 10 V on internal 500 Ω shunt on request). Output current duplication available (D5014D). Response time: 5 ms (0 to 100 % step change). Performance Ref. Conditions: 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature. Calibration accuracy: ≤ ± 0.1 % FSR. Linearity accuracy: ≤ ± 0.05 % FSR. Temp. influence: ≤ ± 0.01 % FSR on zero/span for a 1 °C change. Isolation Out/Supply 500 V; Out/Out 500 V. Environmental conditions Operating temperature: temperature limits –40 to +70 °C. Storage temperature: temperature limits –45 to +80 °C. Safety description Associated apparatus and non-sparking electrical equipment. Uo = 25.9 V, Io = 92 mA, Po = 594 mW at terminals 7-8, 9-10. Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals 8-11, 10-12. Ui = 30 V, Ii = 128 mA, Ci = 0 nF, Li = 0 nH at terminals 8-11, 10-12. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C. Mounting DIN-Rail 35 mm, with or without Power Bus or on custom Term. Board. Weight: about 155 g (D5014D), 130 g (D5014S). Connection: by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG). Dimensions: Width 12.5 mm, Depth 123 mm, Height 120 mm.
ORDERING INFORMATION
D5014S: 1 channel D5014D: 2 channels Accessories Bus Connector JDFT049, Bus Mounting Kit OPT5096. Additional installation diagrams may be found in Instruction Manual. Safe Area/Zone 2/Div. 2