Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch
- Lineup includes three contact models with 2NC/1NO and 3NC contact forms and MBB models in addition to the previous contact forms 1NC/1NO, and 2NC. M12-connector models are available, saving on labor and simplifying replacement. Standardized gold-clad contacts provide high contact reliability. Applicable to both standard loads and microloads. Variety of metallic heads available. Model Number Structure Model Number Legend Switch (Standard type) 1. Conduit/Connector size 1:Pg13.5 (1-conduit) 2:G1/2 (1-conduit) 4:M20 (1-conduit) 6:G1/2 (2-conduit) 8:M20 (2-conduit) 9:M12 connector (1-conduit) 2. Built-in Switch A:1NC/1NO (slow-action) B:2NC (slow-action) C:2NC/1NO (slow-action) D:3NC (slow-action) E:1NC/1NO (MBB contact) F:2NC/1NO (MBB contact) 3. Head Mounting Direction F:Four mounting directions possible (Front-side mounting at shipping)/plastic D:Four mounting directions possible (Front-side mounting at shipping)/metal Note: An order for the head part or the switch part alone cannot be accepted. (The Operation Key is sold separately.) Switch (High pull-force type) 1. Conduit size 2:G1/2 (1-conduit) 4:M20 (1-conduit) 2. Built-in Switch A:1NC/1NO (slow-action) B:2NC (slow-action) C:2NC/1NO (slow-action) D:3NC (slow-action) Operation Key 1. Operation Key Type 1:Horizontal mounting 2:Vertical mounting 3:Adjustable mounting (Horizontal) 5:Adjustable mounting (Horizontal/Vertical) Be sure to read the “Safety Precautions” on page 10 and the “Precautions for All Safety Door Switches”. 12 3 D4NS-@@@ 1 2 D4NS-@@F-SJ D4DS-K@
Ordering Information
Switches (Operation Keys are sold separately.) Consult with your OMRON representative when ordering any models that are not listed in this table. * Models with Korean S-mark certification. Type Contact configuration Conduit opening/Connector Model 1-Conduit Slow-action 1NC/1NO Pg13.5 D4NS-1AF * G1/2 D4NS-2AF * M20 D4NS-4AF 2NC Pg13.5 D4NS-1BF * G1/2 D4NS-2BF * M20 D4NS-4BF 2NC/1NO Pg13.5 D4NS-1CF * G1/2 D4NS-2CF * M20 D4NS-4CF 3NC Pg13.5 D4NS-1DF * G1/2 D4NS-2DF * M20 D4NS-4DF Slow-action MBB contact 1NC/1NO Pg13.5 D4NS-1EF G1/2 D4NS-2EF M20 D4NS-4EF 2NC/1NO Pg13.5 D4NS-1FF G1/2 D4NS-2FF M20 D4NS-4FF 2-Conduit Slow-action 1NC/1NO G1/2 D4NS-6AF M20 D4NS-8AF 2NC G1/2 D4NS-6BF M20 D4NS-8BF 2NC/1NO G1/2 D4NS-6CF M20 D4NS-8CF 3NC G1/2 D4NS-6DF M20 D4NS-8DF Slow-action MBB contact 1NC/1NO G1/2 D4NS-6EF M20 D4NS-8EF 2NC/1NO G1/2 D4NS-6FF M20 D4NS-8FF 1-Conduit, with connector Slow-action 1NC/1NO M12 connector D4NS-9AF 2NC D4NS-9BF Slow-action MBB contact 1NC/1NO D4NS-9EF 1-Conduit (High pull-force type) Slow-action 1NC/1NO G1/2 D4NS-2AF-SJ * M20 D4NS-4AF-SJ * 2NC G1/2 D4NS-2BF-SJ * M20 D4NS-4BF-SJ * 2NC/1NO G1/2 D4NS-2CF-SJ * M20 D4NS-4CF-SJ * 3NC G1/2 D4NS-2DF-SJ * M20 D4NS-4DF-SJ * : Models with certified direct opening contacts.
Standards and EC Directives Conforms to the following EC Directives:
- Machinery Directive
- Low Voltage Directive
- EN50047
- EN60204-1
- EN1088
- GS-ET-15 Certified Standards *1. Certification for CSA C22.2 No. 14 is authorized by the UL mark. *2. Only certain models have been certified. Certified Standard Ratings TÜV (EN60947-5-1), CCC (GB14048.5) Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch. UL/CSA (UL508, CSA C22.2 No. 14) A300 Q300 Type Model D4DS-K1 D4DS-K2 D4DS-K3 D4DS-K5 Horizontal mounting Vertical mounting Adjustable mounting (Horizontal) Adjustable mounting (Horizontal/Vertical) Certification body Standard File No. TÜV SÜD EN60947-5-1 (certified direct opening) Consult your OMRON representative for details. UL *1 UL508, CSA C22.2 No.14 E76675 CQC (CCC) GB14048.5 2003010305077330 KOSHA *2 EN60947-5-1 2005-197 Item Utilization category AC-15 DC-13 Rated operating current (Ie) 3 A 0.27 A Rated operating voltage (Ue) 240 V 250 V Rated voltage Carry current Current (A) Volt-amperes (VA) Make Break Make Break
120 VAC
7,200 720
240 VAC 30 3
Current (A) Volt-amperes (VA) Make Break Make Break
125 VDC
2.5 A 0.55 0.55 69 69 250 VDC 0.27 0.27
Note: 1. The above values are initial values. 2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. *1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NS in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. *2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative. *3. Do not pass the 3 A, 250 VAC load through more than 2 circuits. *4. These figures are minimum requirements for safe operation. *5. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand. Degree of protection *1 IP67 (EN60947-5-1) Durability *2 Mechanical <Standard type> 1,000,000 operations min. <High pull-force type> 100,000 operations min. Electrical <Standard type> 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) <High pull-force type> 100,000 operations min. (10 A resistive load at 250 VAC) Operating speed 0.05 to 0.5 m/s Direct opening force *4 <Standard type> 60 N min. <High pull-force type> 80 N min. Direct opening travel *4 10 mm min. Contact resistance 25 mΩ max. Minimum applicable load *5 1 mA resistive load at 5 VDC (N-level reference value) Rated insulation voltage (Ui) 300 V Rated frequency 50/60 Hz Protection against electric shock Class II (double insulation) Pollution degree (operating environment) 3 (EN60947-5-1) Impulse withstand voltage (EN60947-5-1) Between terminals of same polarity 2.5 kV Between terminals of different polarity 4 kV Between each terminal and non-current carrying metallic parts 6 kV Insulation resistance 100 MΩ min. Contact gap 2 × 2 mm min. Vibration resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude Shock resistance Destruction 1,000 m/s2 min. Malfunction 300 m/s2 min. Conditional short-circuit current 100 A (EN60947-5-1) Conventional free air thermal current (Ith) 10 A (EN60947-5-1) Ambient operating temperature −30 to 70°C (with no icing) Ambient operating humidity 95% max. Weight Approx. 96 g (D4NS-1CF)
Structure and Nomenclature Structure Contact Form Diagrams Show State with Key Inserted. * MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open contact (NO) closes. Model Contact Contact form Operating pattern Remarks D4NS-@A@ D4NS-@AF-SJ 1NC/1NO D4NS-@B@ D4NS-@BF-SJ 2NC D4NS-@C@ D4NS-@CF-SJ 2NC/1NO D4NS-@D@ D4NS-@DF-SJ 3NC D4NS-@E@ 1NC/1NO MBB * D4NS-@F@ 2NC/1NO MBB * Terminal 12 Terminal 32 (34)Terminal 31 (33) Terminal 32 (34)Terminal 31 (33) Terminal 22 Terminal 12 Terminal 21 Terminal 11Terminal 11 Note: The 2-conduit models have the same terminal arrangement. Operation key hole Head The head can be mounted in four directions. Sealing properties The switch casing ensures IP67 D4NS-@CF-SJ, D4NS-@DF-SJ D4NS-@AF-SJ, D4NS-@BF-SJ Zb 11-12 33-34 ON Extraction completion position Operation Key insertion completion position Stroke Only NC contacts 11-12 have a certified direct opening mechanism. The terminals 11-12 and 33-34 can be used as unlike poles. Zb 11-12 31-32 ON Extraction completion position Operation Key insertion completion position Stroke NC contacts 11-12 and 31-32 have a certified direct opening mechanism. The terminals 11-12 and 31-32 can be used as unlike poles. 33 34 Zb 21-22 33-34 11-12 ON Extraction completion position Operation Key insertion completion position Stroke NC contacts 11-12 and 21-22 have a certified direct opening mechanism. The terminals 11-12, 21-22, and 33-34 can be used as unlike poles. 31 32 Zb 11-12 21-22 31-32 ON Extraction completion position Operation Key insertion completion position Stroke NC contacts 11-12, 21-22, and 31-32 have a certified direct opening mechanism. The terminals 11-12, 21-22, and 31-32 can be used as unlike poles. Zb 11-12 33-34 ON Extraction completion position Operation Key insertion completion position Stroke Only NC contacts 11-12 have a certified direct opening mechanism. The terminals 11-12 and 33-34 can be used as unlike poles. 33 34 Zb 11-12 21-22 33-34 ON Extraction completion position Operation Key insertion completion position Stroke NC contacts 11-12 and 21-22 have a certified direct opening mechanism. The terminals 11-12, 21-22 and 33-34 can be used as unlike poles.
Dimensions (Unit: mm) Dimensions and Operating Characteristics 1-Conduit Models 2-Conduit Models 1-Conduit Connector Models Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before application. 7.5 Head cap 22±0.2 30.2 15.3 4.4 2.5 41 33.5 47±0.2 20±0.1 22±0.1 14.2 31.5 21.5 15.5 30.6 Red Black D4NS-1@F D4NS-2@F D4NS-4@F D4NS-2@F-SJ D4NS-4@F-SJ 2.15±0.05R mounting holes 0Two, 4+0.15 dia. holes depth: 5 15 N max. 30 N max. 6±3 mm (28 mm) 60 N min. 10 mm min. D4NS-1@F D4NS-2@F D4NS-4@F 15N max. (50N max.) 6±3 mm (28 mm) 80N min. 10mm min. D4NS-2@F-SJ D4NS-4@F-SJOperating characteristics Key insertion force Key extraction force Pretravel (PT) Total travel (TT) Direct opening force * Direct opening stroke * * Always maintain the above operating characteristics for safe use. Model 7.5 15.3 42±0.1 40±0.1 30.2 4.4 5.4 33.5 39±0.2 41 2.5 9±0.2 25 dia. 14.2 20.5 15.5 21.5 Cap (both sides) 31.5 30.6 56 max. 3 42±0.2 22±0.1 20±0.1 Red Black D4NS-6@F D4NS-8@F 2.15±0.05R mounting holes 0 Two, 4+0.15 dia. holes depth: 5 15 N max. 30 N max. 6±3 mm (28 mm) 60 N min. 10 mm min. D4NS-6@F D4NS-8@FOperating characteristics Key insertion force Key extraction force Pretravel (PT) Total travel (TT) Direct opening force * Direct opening stroke * * Always maintain the above operating characteristics for safe use. Head cap Model M12 × 1 22±0.2 2.5 20±0.1 22±0.1 30.2 15.3 4.4 (14) 41 33.5 47±0.2 7.5 31.5 21.5 15.5 30.6 14.2 Red Black D4NS-9@F 2.15±0.05R mounting holes 0 Two, 4+0.15 dia. holes depth: 5 15 N max. 30 N max. 6±3 mm (28 mm) 60 N min. 10 mm min. D4NS-9@FOperating characteristics Key insertion force Key extraction force Pretravel (PT) Total travel (TT) Direct opening force * Direct opening stroke * * Always maintain the above operating characteristics for safe use. Head cap Model
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 30 15 17.5 2 8 4.3 D4DS-K1 Four, 2.15R D4DS-K3 Black 2814 6.3 4030 56 20° 9 dia. 4.5 dia. 8 dia. Angle adjustment screw 30 13 15 24 . 10.5 6 79 D4DS-K2 Four, 2.15R D4DS-K5 Black 20.9 2 8 15° 18° 4.5 Mounting Holes (Enlargement) Angle adjustment screws 24.6 22.5 4341 5530 (7)6.5
With Operation Key Inserted (Relationship between Insertion Radius and Key Hole) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. (30.6) (30.6) (15) (33.5) Red Black D4NS-1@F + D4DS-K1 (with Front-inserted Operation Key) 44 to 46.5 Key insertion face Horizontal key insertion radius R ≥ 200 Permissible difference in center lines between the Operation Key and key hole is ±1. 44 to 46.5 Key insertion face Vertical key insertion radius R ≥ 200 Permissible difference in center lines between the Operation Key and key hole is ±1. Red Black The permissible difference in center lines between the Operation Key and key hole is ±1. Horizontal key insertion radius R ≥ 200 Vertical key insertion radius R ≥ 200 54.5 to 57.0 Key insertion face 54.5 to 57.0 Key insertion face D4NS-1@F + D4DS-K1 (with Top-inserted Operation Key) The permissible difference in center lines between the Operation Key and key hole is ±1. (41) (8) (41) (15) (30.6) (15) (30.6) (33.5) (27.5) Red Black D4NS-1@F + D4DS-K2 (with Front-inserted Operation Key) 40 to 42.5 Key insertion face Permissible difference in center lines between the Operation Key and key hole is ±1. 40 to 42.5 Key insertion face Permissible difference in center lines between the Operation Key and key hole is ±1. Horizontal key insertion radius R ≥ 200 Vertical key insertion radius R ≥ 200 Red Black The permissible difference in center lines between the Operation Key and key hole is ±1. Horizontal key insertion radius R ≥ 200 Vertical key insertion radius R ≥ 200 50.5 to 53.0 Key insertion face 50.5 to 53.0 Key insertion face D4NS-1@F + D4DS-K2 (with Top-inserted Operation Key) The permissible difference in center lines between the Operation Key and key hole is ±1. (41) (8) (6) (41) (15)
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. (40±0.15) (30.6) (30.6) (33.5) Red Black D4NS-1@F + D4DS-K3 (with Front-inserted Operation Key) 45 to 47.5 Key insertion face Permissible difference in center lines between the Operation Key and key hole is ±1. 45 to 47.5 Key insertion face Permissible difference in center lines between the Operation Key and key hole is ±1. Horizontal key insertion radius R ≥ 50 Vertical key insertion radius R ≥ 200 Red Black The permissible difference in center lines between the Operation Key and key hole is ±1. Horizontal key insertion radius R ≥ 50 Horizontal key insertion radius R ≥ 200 55.5 to 58.0 Key insertion face 55.5 to 58.0 Key insertion face D4NS-1@F + D4DS-K3 (with Top-inserted Operation Key) The permissible difference in center lines between the Operation Key and key hole is ±1. (41) (8) (41) (30.6) (30.6) (33.5) (43±0.1) (41±0.1) Red Black D4NS-1@F + D4DS-K5 (with Front-inserted Operation Key) 51.9 to 54.4 Key insertion face Permissible difference in center lines between the Operation Key and key hole is ±1. 51.9 to 54.4 Key insertion face Permissible difference in center lines between the Operation Key and key hole is ±1. Horizontal key insertion radius R ≥ 50 Vertical key insertion radius R ≥ 50 Red Black The permissible difference in center lines between the Operation Key and key hole is ±1. Horizontal key insertion radius R ≥ 50 Horizontal key insertion radius R ≥ 50 62.4 to 64.9 Key insertion face 62.4 to 64.9 Key insertion face D4NS-1@F + D4DS-K5 (with Top-inserted Operation Key) The permissible difference in center lines between the Operation Key and key hole is ±1. (41) (8) (41) 43 ± 0.1 41 ± 0.1
Refer to the “Precautions for All Switches” and “Precautions for All Safety Door Switches”. !CAUTION
- Do not use the Switch submersed in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch. (The IP67 degree of protection of the Switch specifies the amount of water penetration after the Switch is submerged in water for a certain period of time.)
- Always attach the cover after completing wiring and before using the Switch. Also, do not turn ON the Switch with the cover open. Doing so may result in electric shock.
- Do not switch circuits for two or more standard loads (250 VAC, 3 A). Doing so may adversely affect insulation performance. Stopper Installation Do not use a Switch as a stopper. Be sure to install a stopper as shown in the following illustration to ensure that the base of the Operation Key does not strike the Head, and adjust the stopper to be within the setting zone (0.5 to 3 mm) of the base of the Operation Key. Do not subject the Switch to a shock that exceeds the Switch's shock resistance of 1,000 m/s The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. Mounting Method Appropriate Tightening Torque
- Loose screws may result in malfunction. Tighten the screws to the specified torques.
- When loosening a screw with an electrical screwdriver or similar tool while pressing down on the screw head, do not continue turning the screw past the point where the threads disengage. Doing so may strip the end of the threads. Mounting Holes
- Use M4 screws and spring washers to mount the Switch and Operation Key, and tighten the screws to a suitable torque. To ensure safety, use screws that cannot be easily removed or another means to prevent the Switch and Operation Key from easily being removed.
- As shown below, two studs with a maximum height of 4.8 mm and a diameter of 4 mm can be provided, the studs inserted into the holes on the bottom of the Switch, and the Switch secured at four locations to increase the mounting strength.
- Set the Operation Key so that it is within 1 mm of the center of the key hole. If the Operation Key is offset or at an angle, accelerated wear or breaking may result.
- Observe the specified insertion radius for the Operation Key and insert it in a direction perpendicular to the key hole. Head Direction
- The rotation of the Switch head may be adjusted to any of the four directions by loosening the head mounting screws at the four corners of the head. Make sure that no foreign materials enter through the head.
- Do not insert or remove the Operation Key with the Switch head removed. Doing so may make it impossible to insert the Operation Key. Securing the Door When the door is closed (with the Operation Key inserted), the Operation Key may exceed the set zone because of, for example, the door's own weight, machine vibration, or the door cushion rubber. Secure the door with a stopper so that the Operation Key remains within the set zone. Electric shock may occasionally occur. Do not use metal connectors or metal conduits. Precautions for Safe Use Precautions for Correct Use Terminal screw 0.6 to 0.8 N·m Cover mounting screw 0.5 to 0.7 N·m Head mounting screw 0.5 to 0.6 N·m Operation Key mounting screw 2.4 to 2.8 N·m Body mounting screw 0.5 to 0.7 N·m Connector 1.8 to 2.2 N·m Cap screw 1.3 to 1.7 N·m Switch Operation key StopperCorrect Incorrect −0.05 −0.15 Switch Mounting Holes and Studs
- 1-Conduit Modules 2.5±0.1 22±0.1 47±0.1 4 -0.05 -0.15 dia. Height: 4.8 max. 20±0.1 22±0.1 Two, M4 42±0.1 39±0.1 20±0.1 22±0.1 40±0.1 42±0.1 2.5±0.1 5.35±0.1 Two, M4 4 -0.05 -0.15 dia. Height: 4.8 max.
- 2-Conduit Modules 15±0.1 Two, M4 40±0.1 Two, M4 41±0.1 or, 43±0.1 Two, M4 Operation Key Mounting Holes
- Horizontal/Vertical Mounting (D4DS-K1/-K2)
- Horizontal Adjustable Mounting (D4DS-K3)
- Horizontal/Vertical Adjustable Mounting (D4DS-K5) Operation Key Set zone (0.5 to 3 mm)
- When connecting with insulation tubes and M3.5 crimp terminals, connect the terminals as shown in the following figure and wire without overriding to the case and the cover. Adequate conductor size is AWG 20 to AWG18 (0.5 to 0.75 mm2). Prepare lead wires using the lengths given in the following diagrams. If lead wires are too long, they will press against the cover causing the cover to not close properly.
- Do not push the crimp terminal and the likes into the opening between the parts to prevent the case from being broken and deformed.
- Use terminals having the thickness of 0.5 mm or less to avoid the contact between the terminal and the Switch case inside. <Reference> The crimp terminals listed below have a thickness of 0.5 mm or less. J.S.T is a Japanese manufacturer. Pin arrangement of connector type
- Suitable socket is XS2F-D421 series (OMRON).
- Refer to the Connector Catalog for corresponding Socket pin numbers and lead wire colors. Socket Tightening (Models with Connectors)
- Turn the tightening screws on the Socket by hand and tighten them until the gap between the Socket and Plug essentially disappears.
- Make sure that the Socket’s connector is tightened securely, otherwise the rated degree of protection (IP67) of the D4NS may not be maintained, or the Socket connector may be loosened by vibration. Conduit Opening
- Use cables with suitable diameters for the connector being used.
- When wiring, place the enclosed cap screw on unused conduit openings (for 2-Conduit Switches) and tighten them to the suitable tightening torque. Recommended Connectors Use the connector with thread section of 9 mm long or less. If a connector with a longer thread section is used, the protruding part may interfere with the other parts inside the body. Use the connectors listed below to ensure IP67 degree of protection. When use LAPP's products, use together with a Seal Packing which is sold separately (Type names, JPK-16, GP-13.5, or GPM20) and tighten with proper tightening torque.
- LAPP is a German manufacturer. Manufacture Type N0.5-3.7 (Straight Type) 1-Conduit Models with 3 Poles 2-Conduit Models with 3 Poles 2221 3433 1211A A C E B D F C E B D F 28 mm Tolerance ±2 mm 33 mm 42 mm 2221 3433 1211A C E B D F ACE BDF 28 mm Tolerance ±2 mm Left hand 42 mm ACE BDF 28 mm Tolerance ±2 mm Right hand 42 mm L l F BD dia. dz dia. t: 0.5 mm dz dia.: 3.7 mm D dia.: 2.9 mm B: 6.6 mm L: 19 mm F: 7.7 mm I: 8.0 mm Correct Incorrect Terminal screw Crimp terminal Size Manufacture Model Applicable cable diameter G1/2 LAPP ST-PF1/2 5380-1002 6.0 to 12.0 mm Pg13.5 LAPP S-13.5 5301-5030 6.0 to 12.0 mm M20 LAPP ST-M20 × 1.5 5311-1020 7.0 to 13.0 mm 2 4 D4NS-9BF (2NC) 1 (11) 3 (31) 2 (12) 4 (32) D4NS-9AF (1NC/1NO) D4NS-9EF (1NC/1NO (MBB)) 1 (11) 3 (33) Pin No. (Terminal No.) 2 (12) 4 (34) Zb Zb
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2012.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2012 All Right Reserved.