forward curved, dual inlet with housing (flange) D4E225-CC01-30 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen County court Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen County court Stuttgart · HRB 590142 Nominal data Type D4E225-CC01-30 Motor M4E074-LA Phase 1~ Nominal voltage VAC 230 Frequency Hz 50 Type of data definition ml Valid for approval / standard CE Speed min-1 1150 Power input W 650 Current draw A 2.84 Motor capacitor µF 25 Capacitor voltage VDB 400 Capacitor standard P2 (CE) Min. back pressure Pa 100 Min. ambient temperature °C -25 Max. ambient temperature °C 30 ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit Subject to alterations Data according to ErP directive Installation category B Efficiency category Total Variable speed drive No Specific ratio* 1.00 * Specific ratio = 1 + pf / 100 000 Pa Actual Request 2013 Request 2015 Overall efficiency ηe 36.5 33.9 40.9 Efficiency grade N 44.6 42 49 Power input Pe kW 0.53 Air flow qv m³/h 1965 Pressure increase pf Pa 361 Speed n min-1 1335 Data established at point of optimum efficiency Item no. 11969-5-9980 · Revision 75470 · Release 2011-12-07 · Page 1 / 4

forward curved, dual inlet with housing (flange) D4E225-CC01-30 Technical features Mass 13 kg Size 225 mm Material of impeller Sheet steel, hot-galvanised Housing material Sheet steel, hot-galvanised Material of support structure Sheet steel, hot-galvanised Motor suspension Motor anti-vibration mounted on both sides Direction of rotation Counter-clockwise, seen on rotor Type of protection IP 22; Depending on installation and position Insulation class "B" Humidity class F2-1 Max. permissible ambient motor temp. (transp./ storage) + 80 °C Min. permissible ambient motor temp. (transp./storage) - 40 °C Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) brought out Protection class I (if protective earth is connected by customer) Product conforming to standard EN 60335-1; CE Approval CCC Item no. 11969-5-9980 · Revision 75470 · Release 2011-12-07 · Page 2 / 4

forward curved, dual inlet with housing (flange) D4E225-CC01-30 Product drawing 1 Connection line ETFE AWG20 0.5mm², 6x brass lead tips crimped Connection screen TOP 2 x grey U1 blue Z brown U2 black PE green / yellow Item no. 11969-5-9980 · Revision 75470 · Release 2011-12-07 · Page 3 / 4

forward curved, dual inlet with housing (flange) D4E225-CC01-30 Charts: Air flow 50 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 400 380 360 340 320 300 280 260 240 220 200 180 160 140 120 100 pfs_E[IN H2O] p f s[Pa] Measurement: LU-35314 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V 230 230 230 230 f Hz n min-1 1150 1195 1300 1395 Pe W 783 689 581 445 I A 3.42 3.05 2.65 2.15 qv m3/h 2975 2700 2215 1300 pfs Pa 100 200 300 360 U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 11969-5-9980 · Revision 75470 · Release 2011-12-07 · Page 4 / 4