D4BS OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
D-104 Safety Sensors / Components Safety-door Switch D4BS Safety-door Switch’s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site
- Conforms to EN (TÜV) standards corresponding to the CE marking.
- Approved by UL, CSA, BIA, and SUVA standards.
- The switch contact is opened by a direct opening mechanism (NC contacts only) when the protective cover is opened. The EN-approved direct opening mechanism is indicated by on the Switch.
- Degree of protection of the switch box: IP67 (EN60947-5-1).
- Series includes models with gold-plated contacts for handling the micro-load range.
- Metric conduit types available. Model Number Structure Model Number Legend
Ordering Information
Type Mounting direction Conduit size 1NC/1NO (Slow-action) 2NC (Slow-action) 1-conduit Front-side mounting Pg13.5 D4BS-15FS D4BS-1AFS G1/2 D4BS-25FS D4BS-2AFS M20 D4BS-45FS D4BS-4AFS 3-conduit Pg13.5 D4BS-55FS D4BS-5AFS G1/2 D4BS-65FS D4BS-6AFS M20 D4BS-85FS D4BS-8AFS 12 3 1 D4BS - S 1. Conduit D4BS - K Switch Operation Key 1. Operation Key Type2. Built-in Switch 3. Head Mounting Direction 1: PG13.5 (1 conduit) 2: G1/2 (1 conduit) 3: 1/2-14NPT (1 conduit) 4: M20 5: PG13.5 (3-conduit) 6: G1/2 (3-conduit) 7: 1/2-14NPT (3-conduit) 8: M20 (3-conduit) 5: 1NC/1NO (slow-action) 6: 1NC/NO (slow-action), gold-plated contacts A: 2NC (slow-action) B: 2NC (slow-action), gold-plated contacts F: Four mounting directions pos- sible (front-side mounting at shipping) 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal)
Operation Keys (Order Separately) Specifications Approved Standards Standards and EC Directives Conforms to the following EC Directives: Machinery Directive Low Voltage Directive EN50041 EN1088 Approved Standard Ratings TÜV (EN60947-5-1) Note: Use a 10-A fuse type a gI or gG that conforms to IEC269 as a short-circuit protection device. UL/CSA (UL508, CSA C22.2 No. 14) A600 Type Model D4BS-K1 D4BS-K2 D4BS-K3 Horizontal mounting Vertical mounting Adjustable mounting (Horizontal) Agency Standard File No. TÜV Rheinland EN60947-5-1 UL UL508 E76675 CSA CSA C22.2 No. 14 LR45746 BIA GS-ET-15 9303323 SUVA SUVA E6187.d R9351022 (Direct open- ing: approved) Utilization category AC-15 Rated operating current (Ie) 2 A Rated operating voltage (Ue) 400 V Rated voltage Carry current Current Volt-amperes Make Break Make Break
120 VAC
60 A 6 A
7,200 VA 720 VA240 VAC 30 A 3 A 480 VAC 15 A 1.5 A 600 VAC 12 A 1.2 A
D-106 Safety Sensors / Components Characteristics Note: 1. The above values are initial values. 2. Although the switch box is protected from dust, oil, or water penetration, do not use the D4BS in places where dust, oil, water, or chemicals may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur. 3. The durability is for an ambient temperature of 5 ° C to 35° C and an ambient humidity of 40% to 70%. Contact your OMRON sales rep- resentative for more detailed information on other operating environments. 4. These figures are minimum requirements for safe operation. Contact Form (Diagrams Show State with Key Inserted) Note: The terminal numbers are in accordance with EN50013, and the contact symbols are in accordance with IEC947-5-1. Degree of protection (see note 2) IP67 (EN60947-5-1) Durability (see note 3) Mechanical:1,000,000 operations min. Electrical:500,000 operations min. (10 A at 250 VAC, resistive load) Operating speed 0.1 m/s to 0.5 m/s Operating frequency 30 operations/min max. Rated frequency 50/60 Hz Contact gap 2 x 2 mm min. Direct opening force (see note 4) 19.61 N min. (EN60947-5-1) Direct opening travel (see note 4) 20 mm min. (EN60947-5-1) Full stroke 23 mm min. Insulation resistance 100 MW min. (at 500 VDC) between terminals of same or different polarity, between each terminal and ground, and between each ter- minal and non-current-carrying metal part Contact resistance 25 m W max. (initial value) Rated insulation voltage (Ui) 600 V (EN60947-5-1) Conventional enclosed thermal current (Ithe) 20 A (EN60947-5-1) Dielectric strength (Uimp) Impulse dielectric strength (Uimp) 4 kV (EN60947-5-1) between ter- minals of same or different polarity, between current-carrying metal parts and ground, and between each terminal and non-current-car- rying metal part Switching overvoltage 1,500 V max. (EN60947-5-1) Conditional short-circuit current 100 A (EN60947-5-1) Pollution degree (operating environment) 3 (EN60947-5-1) Insulation class Class I (with ground terminal) Vibration resistance Malfunction: 10 to 500 Hz, 0.65-mm single amplitude Shock resistance Destruction:1,000 m/s2 min. (IEC68-2-27) Malfunction:300 m/s2 min. (IEC68-2-27) Ambient temperature Operating:-40°C to 80°C (with no icing) Ambient humidity Operating:95% max. Weight Approx. 285 g (in the case of D4BS-15FS) Model Contact form Diagram Remarks D4BS-#5#S 1NC/1NO D4BS-#A#S 2NC 23 24 Zb 11 - 12 23 - 24 Stroke ON Operation Key insertion com- pletion position Extraction completion position Only NC contact 11-12 has an approved direct opening mechanism. Terminals 11-12 and 23-24 can be used as unlike poles. Zb 11 - 12 21 - 22 Stroke ON Operation Key insertion com- pletion position Extraction completion position NC contacts 11-12 and 21-22 have an approved direct opening mechanism. Terminals 11-12 and 21-22 can be used as unlike poles.
Oil Seal (NBR) Conduit Opening Ground Terminal Screw Seal Ring (NBR) Seal Packing (NBR) D4BS's exclusive-use Operation Key is provided to assure accurate switching operation. A triangular Set Zone Mark makes it easy to adjust the operating position when inserting the Operation Key. A shearing force contact separating mechanism (NC contact) is employed, which positively pulls apart the contacts from each other by using shearing force if any abnormality such as contact welding should occur in the contact area. There is a difference in level between the NC and NO terminal, which assures easy wiring. A ground terminal is provided to improve safety. (Built into the Unit.) Available in four different types of conduit threads: Pg 13.5, G1/2, or 1/2-14NPT, M20. The operation plunger employs an oil seal, with which the switch box meets the requirements of IP67 (the sealing capability of the Operation Key's insertion mouth is IP00). The switch head is coated with easy-to-see red paint. The mounting direction of the switch head can be varied to any of the four directions.
D-108 Safety Sensors / Components Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 3. The conduit thread varies with the model as follows:. Switches Operation Keys Conduit thread Model Pg 13.5 D4BS-1 ##S, D4BS-5##S G1/2 D4BS-2 ##S, D4BS-6##S M20 D4BS-4 ##S, D4BS-8##S 31.4 66.4 50.9 5.3 (110) 28.5 41 16 34.5 75.471.4 17.2 35.7 38.3 31.4 7.3 5.3 (111.5) 41 16 34.5 60±0.2 30±0.1 40+1 31.5 Two caps Cover Two, 5+0.15 dia. holes (6 mm deep)-0 Cover 1-conduit 3-conduit Red Red D4BS-1##S D4BS-2##S D4BS-4##S D4BS-5##S D4BS-6##S D4BS-8##S Two, 5.3 dia. mounting holes Two, M4 cover clamping screws Four, M3.5 head clamping screws Four, M3.5 head clamping screws Six, 5.3 dia. mounting holes Four, M3.5 x 10 cover clamping screws D4BS-1##S: Pg13.5 D4BS-2##S: G1/2 D4BS-4##S: 1/2-14NPT D4BS-5##S: 3-Pg13.5 D4BS-6##S: 3-G1/2 D4BS-8##S: 3-1/2-14NPT 30±0.2 19.61 N max. 19.61 N max. 10±5 mm 19.61 N min. 20 mm min. D4BS-1##S D4BS-2##S D4BS-4##S Operating characteristics Key insertion force Key extraction force Pretravel (PT) Direct opening force Direct opening stroke 19.61 N max. 19.61 N max. 10±5 mm 19.61 N min. 20 mm min. D4BS-5##S D4BS-6##S D4BS-8##S Operating characteristics Key insertion force Key extraction force Pretravel (PT) Direct opening force Direct opening stroke 2012 (80.7) 11.4 34.6 17.5 2.5 (37.8) 30±0.15 53.7 13 11.4 2.5 36 5.3 12 7.5 40±0.15 52.426 15 40.7 78.7 7.3 15 5.3 5.3 7.52.5 11.4 20±0.15 19.5±0.15 4 dia. M4 Allen-head bolt 5.3 ¥ 7.3 mounting long hole 4 dia.4 dia. Two, 2.65R D4BS-K1 D4BS-K2 D4BS-K3 Black Black Black Red 5.3 dia. mounting hole
With Operation Key Inserted Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Horizontal Mounting Vertical Mounting Note: "R" is the Operation Key insertion radius. Adjustable Mounting (Horizontal) Red Red Red D4BS-1##S +D4BS-K1 D4BS-2##S +D4BS-K1 D4BS-4##S +D4BS-K1 53.5 min. 58 max. Operation Key insertion radius in horizontal direction: R ≥ 1200 53.5 min. 58 max. Operation Key insertion radius in horizontal direction: R ≥ 1000 D4BS-1##S +D4BS-K2 D4BS-2##S +D4BS-K2 D4BS-4##S +D4BS-K2 54.5 min. 59 max. Operation Key insertion radius in horizontal direction: R ≥ 1200 54.5 min. 59 max. Operation Key insertion radius in horizontal direction: R ≥ 1000 D4BS-1##S +D4BS-K3 D4BS-2##S +D4BS-K3 D4BS-4##S +D4BS-K3 81.5 min. 86 max. Operation Key insertion radius in horizontal direction: R ≥ 150 81.5 min. 86 max. Operation Key insertion radius in horizontal direction: R ≥ 1000
D-110 Safety Sensors / Components Precautions Caution Do not dismount the Operation Key from the door intentionally and insert it to the Switch with the door open. Machine may start oper- ating and injury or death may be caused. Mount the Operation Key at a location where it will not come in con- tact with users when the door is opened or closed. When operating the D4BS as a part of a safety category circuit to prevent injury, operate the NC contacts that have a direct opening mechanism in direct opening mode. For safety purposes, tighten the switch body and Operation Key with one-way screws or equivalents or install a switch protection cover and warning label for safety pur- poses to prevent easy removal of the D4BS. Connect the fuse to the D4BS in series to prevent it from short-circuit damage. The value of the breaking current of the fuse must be calcu- lated by multiplying rated current by 150% to 200%. When using the D4BS with EN ratings, use 10-A fuse Type gI or gG that complies with IEC60269. Correct Use Operating Environment Make sure in advance that the environment is suitable, with no oil, water, or chemicals, as these ma y cause the seal to deteriorate, resulting in faulty contact, faulty is olation, current leakage, or burn- ing. Do not use the D4BS in the following locations: Locations subject to severe temperature changes Locations subject to high temperatures or condensation Locations subject to severe vibration Locations where the product may come into direct contact with pro- cessing waste or dust Operation Key Be sure to use a special Operation Key only. Do not operate the D4BS with anything other than the special Operation Key, otherwise the D4BS may break or the safety of the system may not be main- tained. Do not impose excessive force on the Operation Key inserted into the D4BS or drop the D4BS with the Operation Key inserted, other- wise the Operation Key may deform or break. Secure the Operation Key with a one-way screw, or an equivalent, so that the Operation Key cannot be easily removed. Securing the Door If the Operation Key on the closed door is pulled outside the set zone by a force caused by vibration, the door’s weight, or the door cushion rubber, the switch contact may be opened (causing the machinery to stop) or the D4BS may be damaged. Secure the door with hooks so that it will remain within the set zone. Mounting Do not use the Switch as a stopper. Be sure to install a stopper as shown in the following illustration when mounting the Switch. The range of space “a” must be determined according to the available set zone of the Operation Key. Refer to Dimensions for the mounting dimension of the Operation Key and mount the Operation Key correctly. The Operation Key will soon become damaged or worn out if it is not mounted correctly. Make sure that the Operation Key can be inserted properly with a tol- erance of ±0.5 mm in the upward, downward, left, or right direction, otherwise the D4BS may soon become damaged. Excessive force Drop Extra space Set zone a Stopper Switch ±0.5 min. ±0.5 min.
Make sure that the D4BS is located outside the safety door and that no metal dust, oil, or chemical will be sprayed onto the D4BS. Other- wise, the D4BS may soon fail to operate due to the penetration of metal dust, oil, or chemical. Tightening Torque Be sure to tighten each screw of the D4BS properly, otherwise the D4BS may malfunction. Note: 1. Apply a torque of 0.78 o 0.88 N·m if the D4BS is a three-con- duit model. 2. Apply a torque of 4.90 to 5.88 N·m in the case of an Allen- head bolt. If it is a pan head screw, apply a torque of 2.35 to 2.75 N·m. Mounting Dimensions (M5) The D4BS can be mounted more securely by adding two protruding portions, each of which is 5 mm maximum in height and –0.05/–0.15 mm in diameter as shown below. Operating Key Mounting Dimensions Changes in Head Mounting Direction By removing the screws on the four corners of the head, the head can be reset in any of four directions. The head direction can be changed with or without the Operation Key inserted in the head. Make sure that no foreign materials penetrate through the head and that the head is tightened securely within the proper torque range. No. Type Torque 1 M3.5 terminal screw (including ground terminal screw) 0.59 to 0.78 N·m
2 Cover mounting screw
(see note 1) 1.18 to 1.37 N·m 3 Head mounting screw 0.78 to 0.98 N·m
4 M5 body mounting screw
(see note 2) 4.90 to 5.88 N·m 5 Operation Key mounting screw 2.35 to 2.75 N·m 6 Connector 1.77 to 2.16 N·m 7 Cap screw 1.27 to 1.67 N·m 27±0.1 59.3±0.160 Mounting hole Mounting side Standard Model Three-conduit Model Protruding portions 5 -0.05 dia. holes, max. height 5-0.15 -0.15 Insertion hole for protrusions 5-0.05 dia. holes, max. height 5 20±0.1 40±0.1 30±0.1 Horizontal Mounting Vertical Mounting Adjustable Mounting (Horizontal) Two, M5 Two, M5 Two, M5
D-112 Safety Sensors / Components Wiring Do not connect the lead wires directly to the terminals. Connect the lead wires through insulation tubes and M3.5 crimp terminals. Tighten each terminal screw within the proper torque range. The proper lead wire is AWG20 to AWG14 (0.5 to 2.5 mm 2) in size. Make sure that all crimp terminals are correctly connected and located within the casing or cover as shown below. Connector Tighten the connector to a suitable torque. Excessive tightening torque may damage the casing. When using a 1/2-14NPT conduit, apply sealing tape between con- nector and conduit opening so that the enclosure will confirm to IP67. If using a Pg13.5 conduit, use an ABS-08 Pg13.5 connector or an ABS-12 Pg13.5 connector (manufactured by Nippon Flex). Use a connector (SC Series, sold separately) suitable for the outer diameter of the cable. When wiring a 3-conduit model, se curely tighten the cap screw pro- vided for unused conduit openings. Maintenance and Repairs The user must not maintain or repair equipment incorporating any D4BS model. Contact the manufacturer of the equipment for any maintenance or repairs required. D dia. dz dia. dz dia.: 3.7 D dia.: 4.5 B: 7.0 L: 20.2 F: 7.7 I: 9.0 (mm) Casing Cover Terminal screw Crimp terminal Terminal screw Casing Terminal screw Cover Crimp terminal Correct Correct Incorrect Incorrect Crimp terminal Crimp terminal Crimp terminal