Sealed Snap Action Switch D2VW 207 Sealed Snap Action Switch D2VW Watertight Miniature Snap Action Switch

  • High-quality watertight, high-precision miniature Snap Action switch. Switch Body meets IP67 requirements  Use of epoxy resin assures high sealing capability and is ideal for dusty places or where water is sprayed  V-series internal mechanism assures high precision and long life  General-load (5 A at 250 VAC) models and micro-load models are available  RoHS Compliant

Ordering Information

Note: 1. The standard lengths of the lead wires (UL1015 AWG20 for UL/CSA models, AV0.75f otherwise) of models incorporating them are 30 cm. 2. Remove “-HS” from the end of solder/quick-connect models to obtain non-UL/CSA versions. (e.g.: D2VW-01-1HS → D2VW-01-1) Model Number Legend Actuator Terminal Model Model 0.1 A Model 5 A Pin plunger With solder and #187 tab terminals D2VW-01-1HS D2VW-5-1HS With lead wires D2VW-01-1MS D2VW-5-1MS Short hinge lever With solder and #187 tab terminals D2VW-01L1A-1HS D2VW-5L1A-1HS With lead wires D2VW-01L1A-1MS D2VW-5L1A-1MS Hinge lever With solder and #187 tab terminals D2VW-01L1-1HS D2VW-5L1-1HS With lead wires D2VW-01L1-1MS D2VW-5L1-1MS Long hinge lever With solder and #187 tab terminals D2VW-01L1B-1HS D2VW-5L1B-1HS With lead wires D2VW-01L1B-1MS D2VW-5L1B-1MS Simulated roller lever With solder and #187 tab terminals D2VW-01L3-1HS D2VW-5L3-1HS With lead wires D2VW-01L3-1MS D2VW-5L3-1MS Short hinge roller lever With solder and #187 tab terminals D2VW-01L2A-1HS D2VW-5L2A-1HS With lead wires D2VW-01L2A-1MS D2VW-5L2A-1MS Hinge roller lever With solder and #187 tab terminals D2VW-01L2-1HS D2VW-5L2-1HS With lead wires D2VW-01L2-1MS D2VW-5L2-1MS D2VW- - 1. Ratin gs 5: 5 A at 250 VAC 01: 0.1 A at 30 VDC 2. Actuator None: Pin pl unger L1A: Short hinge le ver L1: Hinge le ver L1B: Long hinge le ver L3: Sim ulated roller lever L2A: Short hinge roller le ver L2: Hinge roller le ver 3. Contact Form 1: SPDT 2: SPST-NC* 3: SPST-NO* *Lead wire versions only 4. Terminals None, HS: Solder terminals (HS for UL and CSA approval.) M, MS: Molded lead wires (MS for UL and CSA approval) 3 421

208 Sealed Snap Action Switch D2VW

■Characteristics Note: 1. Data shown are of initial value. 2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate. 3. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, the values apply at the total travel position. 4. The operating temperature of the lead wire (AV0.75f) for non-UL/CSA molded lead wire models is between -40 to 85°C. ■Ratings (reference values) D2VW-5 D2VW-01 Note: 1. The resistive load ratings apply under the following test conditions: Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min. 2. The above current ratings are the values of the steady-state current. 4. Lamp load has an inrush current of 10 times the steady-state current. 5. Rating for UL/CSA approval is as follows (See “Approved Standards” section): Model D2VW-01 D2VW-5 Operating speed 0.1 mm to 1 m/s (at pin plunger) Operating frequency Mechanical: 300 operations/minute max. Electrical: 30 operations/minute max. Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 50 mΩ max. (100 mΩ max. for molded lead wire models) Dielectric strength (See note 2) 1,000 VAC, 50/60 Hz for 1 min. between terminals of the same polarity 1,500 VAC, 50/60 Hz for 1 min. between each current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts. Vibration resistance (See note 3) Malfunction: 10 to 55 Hz, 1.5 mm double amplitude Shock resistance (See note 3) Destruction: 1,000 m/s 2 (approx. 100G) max. Malfunction: 300 m/s2 (approx. 30G) max. Degree of protection IEC IP67 (excluding the terminals on terminal models). Degree of protection against electric shock Class I Proof tracking index (PTI) 175 Ambient operating temperature -40° to 85°C (at 60% RH max.) with no icing Ambient operating humidity 95% max. (for 5°C to 35°C) Life expectancy Mechanical 10,000,000 operations min. at 60 operations per minute Weight Approx. 7g (pin plunger models without wires) Rated Voltage Non-inductive load Inductive load Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 5 A 0.5 A 4 A — 250 VAC 5 A 0.5 A 4 A — 3 0 V D C 5 A3 A4 A— 125 VDC 0.4 A 0.1 A 0.4 A — Rated Voltage Non-inductive load Inductive load Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 0.1 A — — — 30 VDC 0.1 A — — — D2VW-01 0.1A @ 125 VAC 0.1A @ 30 VDC D2VW-5 3A @ 125 VAC, 250 VAC

Sealed Snap Action Switch D2VW 209 ■Approved Standards Consult your OMRO N sales representative for specific models with standard approvals. UL Recognized, CSA Certified EN 61058-1 (VDE Approval) Testing conditions: 25E3 (25,000 operations), T85 (0°C to 85°C) for D2VW-5 1E5 (100,000 operations), T85 (0°C to 85°C) for D2VW-01 ■Contact Specifications Note: Minimum applicable loads are indicated by N standard refer- ence values. This value represents the failure rate at a 60% (λ60) reliability level (JIS C5003). The equation λ60=0.5 x 10-6 / operations indicates that a failure rate of 1/2,000,000 operations can be expected at a reliability level of 60% Engineering Data ■Structure ■Mounting All switches may be panel mounted using M3 mounting screws with plane washers or spring washers to securely mount the switch. Tighten the screws to a torque of 0.39 to 0.59 N·m. Rated Voltage D2VW-5 D2VW-01

125 VAC

250 VAC

0.1 A - - - 30 VDC - - - 0.1 A Rated Voltage D2VW-5 D2VW-01

  • - - 3 A 0.1 A - - - Item D2VW-5 D2VW-01 Specification Rivet Crossbar Material Silver alloy Gold alloy Gap (standard value) 0.5 mm Inrush current NC: 15 A max. NO: 15 A max. - - - Minimum applicable load (see note) 160 mA at 5 VDC 1 mA at 5 VDC NC (red) NO (blue) COM (black) SPDT NC (red) COM (black) SPST-NC NO (blue) COM (black) SPST-NO Note: Colors in parentheses indicate lead wire colors. Two, 3.1-dia. mounting holes or M3 screw holes 22.2 ± 0.1 10.3 ± 0.1

210 Sealed Snap Action Switch D2VW

■Terminals Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions 2. The pin plunger model is shown here as a typical example for both the solder/quick connect terminals and the molded lead wire versions. ■Dimensions and Operating Characteristics Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions 2. Omitted dimensions are the same as pin plunger type. 3. The operating characteristics are for operation in the A direction( ) Solder/Quick Connect Terminals t=0.5 Three, solder terminals 1.3 dia. hole2.4 dia. hole 8.4 5.2 1.2 4.810.3 2.5 5.2 5.2 41.4 22.2±0.1 0.5 2.8 Molded Lead Wires * UL/CSA approved models have AWG20 UL approved wiring. AV 0.75f Lead wire (red)* AV 0.75f Lead wire (blue)* AV 0.75f Lead wire (black)* 2.8 (5) 10.3 22.2±0.1 300±10 Pin Plunger Models D2VW-01-1HS D2VW-5-1HS t=0.5 Three, solder terminals 1.3 dia. hole2.4 dia. hole 8.4 5.2 1.2 4.810.3 20.2±0.25 2.5 dia. 2.5 5.2 5.2 41.4 22.2±0.1 10.3±0.115.9OP PT 2.8 3.1+0.13 –0.03 3.1+0.13 –0.03 dia. holes 0.5 3.2±0.1 dia. 2.8 A OF max 200 gf RF min. 30 gf PT max. 1.2 mm OT min. 1.0 mm MD max. 0.4 mm OP 14.7 ± 0.4 mm Short Hinge Lever Models D2VW-01L1A-1MS D2VW-5L1A-1MS PT OP 10.3 4.3 15.9 *Stainless-steel lever t=0.5* 24.3±0.8A OF max 200 gf RF min. 20 gf PT max. 1.6 mm OT min. 0.8 mm MD max. 0.5 mm OP 15.2 ± 0.5 mm Hinge Lever Models D2VW-01L1-1MS D2VW-5L1-1MS PT OP 10.3 4.3 *Stainless-steel lever 5t=0.5* 35.6±0.8 15.9 A OF max 120 gf RF min. 15 gf PT max. 4.0 mm OT min. 1.6 mm MD max. 0.8 mm OP 15.2 ± 1.2 mm

Sealed Snap Action Switch D2VW 211 Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions 2. Omitted dimensions are the same as pin plunger type. 3. The operating characteristics are for operation in the A direction( ) Long Hinge Lever Models D2VW-01L1B-1MS D2VW-5L1B-1MS PT OP 10.3 4.3 15.9 *Stainless-steel lever 5t=0.5* 59.4±0.8A OF max 60 gf RF min. 5 gf PT max. 9.0 mm OT min. 3.2 mm MD max. 2.0 mm OP 15.2 ± 2.6 mm Simulated Roller Lever Models D2VW-01L3-1MS D2VW-5L3-1MS 5 4.3 10.3 3.5R t=0.5*PT OP 32.6±0.8 *Stainless-steel lever 15.9 t=0.5* A OF max 120 gf RF min. 15 gf PT max. 4.0 mm OT min. 1.6 mm MD max. 0.8 mm OP 18.7 ± 1.2 mm Short Hinge Roller Lever Models D2VW-01L2A-1MS D2VW-5L2A-1MS 24.3±0.8 20.1±0.8 t=0.5* 4.8 dia. 4.8 ** PT 7.2 10.3 15.9 OP *Stainless-steel lever Oil-less polyacetal resin roller OF max 230 gf RF min. 20 gf PT max. 1.6 mm OT min. 0.8 mm MD max. 0.5 mm OP 20.7 ± 0.6 mm Hinge Roller Lever Models D2VW-01L2-1MS D2VW-5L2-1MS 4.8 dia. 4.8 7.2 10.3 *Stainless-steel lever **Oil-less polyacetal resin roller t=0.5* 34±0.8 PT OP 15.9 A OF max 120 gf RF min. 15 gf PT max. 4.0 mm OT min. 1.6 mm MD max. 0.8 mm OP 20.7 ± 1.2 mm

212 Sealed Snap Action Switch D2VW

Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide, “Snap Action Switches, Technical Information” for correct use. ■Correct Use Operations Make sure that the switching object is perfectly separated from the actuator when the switch is not operated and the actuator is pressed appropriately by the switching object when the switch is operated. The switch should be set so that its stroke will be within the rated OT when the switch is operated. With the pin plunger models, set the switch so that the plunger can be actuated from directly above. Since the plunger is covered with a rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability. Handling Handle the switch carefully so as not to break the sealing rubber of the plunger. Using Microloads Using a model for ordinary loads to switch microloads may result in faulty operation. Instead, use the models that are designed for microloads and that operate in the following range; However, even when using microload models within the operating range shown above, if inrush current or inductive voltage spikes occur when the contact is opened or closed, then contact wear may increase and so decrease the service life. Therefore, insert a contact protection circuit where necessary. ■Cautions Degree of Protection The D2VW was tested under water and passed the following water- tightness test, which however, does not mean that the D2VW can be used in the water. JIS C0929 (rules for testing the wate rtightness of electrical devices and materials), class 7 (watertightness test). Refer to the following illustration for the test method at OMRON. Note: The object to be tested is left in the water for 30 minutes on con- dition that the distance between the surface of the water and the top of the object be 15 cm minimum and the distance be- tween the surface of the water and the bottom of the object be 1 m minimum. Protection Against Chemicals Prevent the switch from coming in to contact with oil and chemicals. Otherwise, damage to or deterioration of the switch materials may occur. Correct IncorrectIncorrect Operating range for micro load models D2VW-01 Operating range for general-load models D2VW-05 Current (mA) Voltage (V) Inoperable range 1 10 100 1,000 0.16mA 100mA 100mA 160mA 26mA 1mA

Sealed Snap Action Switch D2VW MEMO

Sealed Snap Action Switch D2VW OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Cat. No. X303-E-1 Printed in USA OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 11/10 Specifications subject to change without notice All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.