D S D2S Subminiature Basic Switch Subminiature Switch with Superb Flux Resistance
- One-piece terminal construction to keep out flux.
- High operating-position accuracy (±0.25 mm) enables easy peripheral design and positioning. Use of pin plunger also allows horizontal operation. RoHS Compliant Model Number Legend List of Models Ratings 10.1 A 5 A 0.1 A Actuator Terminals OF max. Pin plunger Solder terminals
1.47 N {150 gf} D2S-10 D2S-5 D2S-01
0.49 N {50 gf} - D2S-5-F D2S-01-F
1.47 N {150 gf} D2S-10D D2S-5D D2S-01D
0.49 N {50 gf} - D2S-5-FD D2S-01-FD
Hinge lever Solder terminals
0.49 N {50 gf} D2S-10L D2S-5L D2S-01L
0.18 N {18 gf} - D2S-5L-F D2S-01L-F
0.49 N {50 gf} D2S-10LD D2S-5LD D2S-01LD
0.18 N {18 gf} - D2S-5L-FD D2S-01L-FD
Simulated roller lever Solder terminals
0.49 N {50 gf} D2S-10L13 D2S-5L13 D2S-01L13
0.18 N {18 gf} - D2S-5L13-F D2S-01L13-F
0.49 N {50 gf} D2S-10L13D D2S-5L13D D2S-01L13D
0.18 N {18 gf} - D2S-5L13-FD D2S-01L13-FD
Hinge roller lever Solder terminals
0.49 N {50 gf} D2S-10L2 D2S-5L2 D2S-01L2
0.18 N {18 gf} - D2S-5L2-F D2S-01L2-F
0.49 N {50 gf} D2S-10L2D D2S-5L2D D2S-01L2D
0.18 N {18 gf} - D2S-5L2-FD D2S-01L2-FD
D2S- @@@@ 1. Ratings 10 : 250 VAC 10.1 A 5 : 125 VAC 5 A 01 : 30 VDC 0.1 A 2. Actuator None : Pin plunger L : Hinge lever L13 : Simulated roller lever L2 : Hinge roller lever 1234 3. Maximum Operating Force (OF) None : 1.47 N {150 gf} -F : 0.49 N {50 gf} (For 0.1 A, 5 A) Note: The given values are for pin plunger models only. 4. Terminals None : Solder terminals D : Self-clinching PCB terminals Separator (Sold Separately), Terminal Connector (Sold Separately) Refer to "Basic Switch Common Accessories"
D2S Subminiature Basic Switch D S Contact Form Contact Specifications * Please refer to " Using Micro Loads" of "●Precautions" for more information on the minimum applicable load. Item Model D2S-10 models D2S-5 models D2S-01 models Contact Specification Rivet Crossbar Material Silver alloy Gold alloy Gap (standard value) 0.5 mm Inrush current NC 20A max. 1 A max. NO 15 A max. 10 A max. 1 A max. Minimum applicable load (reference value) * 5 VDC 160 mA 5 VDC 1 mA
- SPDT COM NO NC Characteristics Note. The data given above are initial values. *1. The values for dielectric strength shown are for models with a Separator (refer to "Micro Switch Common Accessories"). *2. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1ms max. *3. For testing conditions, consult your OMRON sales representative. Item Model D2S-10 models D2S-5 models D2S-01 models Permissible operating speed 0.1 mm to 1 m/s (for pin plunger models) Permissible operating frequency Mechanical 400 operations/min Electrical 60 operations/min Insulation resistance 100 M Ω min. (at 500 VDC with insulation tester) Contact resistance (initial value) OF 1.47 N models 30m Ω max. 50 m Ω max. OF 0.49 N models - 50 m Ω max. 100 m Ω max. Dielectric strength * 1 Between terminals of the same polarity 1,000 VAC 50/60 Hz 1 min Between current-carrying metal parts and ground 1,500 VAC 50/60 Hz 1 min Between each terminals and non-current-carrying metal parts 1,500 VAC 50/60 Hz 1 min Vibration resistance * 2 Malfunction 10 to 55 Hz, 1.5 mm double amplitude Shock resistance Durability OF 1.47 N models 1,000 m/s 2 {approx. 100G} max. OF 0.49 N models 500 m/s 2 {approx. 50G} max. Malfunction * 2 OF 1.47 N models 300 m/s 2 {approx. 30G} max. OF 0.49 models 200 m/s 2 {approx. 20G} max. Durability * 3 Mechanical 10,000,000 operations min. (60 operations/min) 30,000,000 operations min. (60 operations/min) Electrical 50,000 operations min. (30 operations/min) 200,000 operations min. (30 operations/min) Degree of protection IEC IP40 Ambient operating temperature -25°C to +85°C (at ambient humidity of 60% max.) (with no icing or condensation) Ambient operating humidity 85% max. (for +5°C to +35°C) Weight Approx. 1.6 g (pin plunger models) Ratings Note. The above rating values apply under the following test conditions. (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5% (3) Operating frequency: 30 operations/min Approved Safety Standards The items shown in the "List of Models" are not standard approved models. Consult your OMRON sales representative for specific models with standard approvals. UL (UL1054)/CSA(CSA C22.2 No.55) Model Item Rated voltage Resistive load D2S-10 models 250 VAC 10.1 A D2S-5 models
125 VAC
250 VAC
125 VAC 0.1 A 30 VDC 0.1 A Rated voltage Model D2S-10 D2S-5 D2S-01 10.1 A 5 A 3 A 0.1 A 30 VDC - - 0.1 A
D2S Subminiature Basic Switch D S Dimensions (Unit: mm) and Operating Characteristics The following figures show models with self-clinching PCB terminals. For the solder terminals, refer to "Terminals/Appearances". The @ is replaced with the code for the terminal that you need. See the "List of Models" for available combinations of models. Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). Terminals/Appearances (Unit: mm)
- Solder terminals ●Self-clinching PCB terminals <PCB Mounting Dimensions (Reference)> 3.3±0.1 6.4±0.2 0.5 16.1±0.21.85 9.5±0.1 8.8±0.2 1.6 3.2 7.3 5.15 3-1.6 dia.holes 3.3±0.1 6.4±0.2 0.5 1.3 16.1±0.21.85 9.5±0.15.15 8.8±0.2 0.8 1.2 1.8±0.1 3.9 8.8±0.2 3-1.35㹼1.5 dia. 16.1±0.2 PCB's thickness t㸻1.6mm Mounting Holes (Unit: mm) 9.5±0.1 2-2.4 dia. mounting holes or M2.3 screw holes 7.5±0.1 1.8 㸦5.3㸧 2.35±0.05 dia. 2.35±0.05 dia. 7 7.7 OP PT 3.6 3.3±0.1 3.9 6.4±0.2 0.5 1.8±0.1 1.3 19.8±0.2 16.1±0.2 9.5±0.1 A
- Pin plunger D2S-10@ D2S-5@ D2S-5-F@ D2S-01@ D2S-01-F@ Operating characteristics Model D2S-10@ D2S-5@ D2S-01@ D2S-5-F@ D2S-01-F@ Operating Force OF Max. Releasing Force RF Min.
1.47 N {150 gf}
0.25 N {25 gf}
0.49 N {50 gf}
0.04 N {4 gf}
Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 0.7 mm 0.4 mm 0.1 mm Operating Position OP 8.4 ±0.25 mm
- Hinge lever D2S-10L@ D2S-5L@ D2S-5L-F@ D2S-01L@ D2S-01L-F@ Operating characteristics Model D2S-10L@ D2S-5L@ D2S-01L@ D2S-5L-F@ D2S-01L-F@ Operating Force OF Max. Releasing Force RF Min.
0.06 N {6 gf}
0.18 N {18 gf}
0.02 N {2 gf}
Overtravel OT Min. Movement Differential MD Max. 1.0 mm 0.8 mm Free Position FP Max. Operating Position OP 13.6 mm 9.4 ±0.8mm 14.5t㸻0.3 * 2.35±0.05 dia. 2.35±0.05 dia. 7 7.7 OP FP 3.6 3.3±0.1 3.9 * Stainless-steel lever 6.4±0.2 0.5 1.3 19.8±0.2 16.1±0.2 9.5±0.1 A 1.8±0.1
- Simulated roller lever D2S-10L13@ D2S-5L13@ D2S-5L13-F@ D2S-01L13@ D2S-01L13-F@ Operating characteristics Model D2S-10L13@ D2S-5L13@ D2S-01L13@ D2S-5L13-F@ D2S-01L13-F@ Operating Force OF Max. Releasing Force RF Min.
Overtravel OT Min. Movement Differential MD Max. 1.0 mm 0.8 mm Free Position FP Max. Operating Position OP 15.5 mm 11.4 ±0.8 mm 15.8 t㸻0.3 * 2.35±0.05 dia. 2.35±0.05 dia. R1.3 7 7.7 OP FP 3.6 3.3±0.1 3.9 *Stainless-steel lever 6.4±0.2 0.5 1.3 19.8±0.2 16.1±0.2 9.5±0.1 A 1.8±0.1
D2S Subminiature Basic Switch D S Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). Precautions ★ Please refer to "Basic Switches Common Precautions" for correct use.
- Soldering When using automatic soldering baths, we recommend soldering at 260±5°C within 5 seconds. Make sure that the liquid surface of the solder does not flow over the edge of the board. When soldering terminals manually, complete the soldering at the iron tip temperature between 350 to 400°C within 3 seconds, and do not apply any external force for 1 minute after soldering. When applying solder, keep the solder away from the case of the Switch and do not allow solder or flux to flow into the case.
- Mounting Use M2.3 mounting screw with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of
- Using Micro Loads Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the following operating range, if inrush current occurs when the contact is opened or closed, it may increase the contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The N-level reference value applies for the minimum applicable load. This value indicates the malfunction reference level for the reliability level of 60% (λ 60). (JIS C5003) The equation, λ60=0.5×10-6/operations indicates that the estimated malfunction rate is less than operations with a reliability level of 60%.
- Hinge roller lever D2S-10L2@ D2S-5L2@ D2S-5L2-F@ D2S-01L2@ D2S-01L2-F@ Operating characteristics Model D2S-10L2@ D2S-5L2@ D2S-01L2@ D2S-5L2-F@ D2S-01L2-F@ Operating Force OF Max. Releasing Force RF Min.
Overtravel OT Min. Movement Differential MD Max. 1.0 mm 0.8 mm Free Position FP Max. Operating Position OP 19.3 mm 15.1±0.8 mm 14.5 t=0.3 *1 2.35±0.05 dia. 2.35±0.05 dia. 7 7.7 OP FP 4.8x3.2 *2 dia. 3.3±0.1 3.9 *1. Stainless-steel lever *2. Polyacetal resin roller 6.4±0.2 0.5 1.3 19.8±0.2 16.1±0.2 9.5±0.1 A 1.8±0.1 Cautions Correct Use 2,000,000 1 10 100 1,000 Current (mA) 0.1 1 mA Normal load type Operating range D2S-5 D2S-10 Micro load type Operating range D2S-01 26 mA0.16 mA 100 mA 160 mA 100 mA Voltage (V)
D2S Subminiature Basic Switch D S Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying t he product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other sys tems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product p rovide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. B092-E1-05 0812(0207)(O) Note: Do not use this document to operate the Unit.