D2RV-L22 OMRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

D R V D2RV Miniature Basic Switch High Reliability for Micro Load Applications, Even in Adverse Atmospheres (Dust, High Humidity, Silicon Gas, etc.)

  • The reed switch offers exceptional contact reliability in micro load applications.
  • Same mounting pitch as for the V Miniature Basic Switch.
  • High durability with a bounce time of 1 ms max. RoHS Compliant Model Number Legend List of Models Contact Form Ratings Note. The above rating values apply under the following test conditions. (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5% (3) Operating frequency: 30 operations/min Characteristics Note. The data given above are initial values. *1. The values for dielectric strength shown are for models with a Separator (refer to "Basic Switch Common Accessories"). *2. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, they apply at the total travel position. Close or open circuit of the contact is 1ms max. *3. For testing conditions, consult your OMRON sales representative. Maximum Operating Force (OF) ModelActuator Pin plunger

0.25 N {25 gf} D2RV-E

0.49 N {50 gf} D2RV

0.98 N {100 gf} D2RV-G

0.49 N {50 gf} D2RV-L11

0.98 N {100 gf} D2RV-L11G

Hinge lever 0.25 N {25 gf} D2RV-L

0.49 N {50 gf} D2RV-LG

0.25 N {25 gf} D2RV-L13

0.49 N {50 gf} D2RV-L13G

0.49 N {50 gf} D2RV-L22

0.98 N {100 gf} D2RV-L22G

0.25 N {25 gf} D2RV-L2

0.49 N {50 gf} D2RV-L2G

D2RV- @@12 1. Actuator None : Pin pl unger model L11 : Short hinge lever L : Hinge lever L13 : Simulated roller lever L22 : Short hinge roller lever L2 : Hinge roller lever 2. Maximum Operating Force (OF) None : 0.49 N {50 gf} E : 0.25 N {25 gf} (for pin pl ungers only) G : 0.9 8 N {100 gf} Note. These values are for the pin plunger models. Switching voltage 100 VDC (max.) Switching current 0.25 ADC (max.) Contact capacity 10 WDC (max.) Permissible operating speed 0.1mm to 1 m/s (for pin plunger models) Permissible operating frequency Mechanical 200 operations/min Electrical 200 operations/min Insulation resistance 100 M Ω min. (at 500 VDC with insulation tester) Contact resistance (initial value) 150 m Ω max. Dielectric strength * 1 Between terminals of the same polarity 200 VDC 1 min Between current- carrying metal parts and ground

500 VAC 50/60 Hz for 1 min

resistance * 2 Malfunction 10 to 55 Hz, 1.5 mm double amplitude Shock resistance Destruction 500 m/s 2 {approx. 50G} max. Malfunction * 2 200 m/s 2 {approx. 20G} max. Durability * 3 Mechanical 10,000,000 operations min. (60 operations/min) Electrical 3,000,000 operations min. (30 operations/min) Degree of protection IEC IP40 Ambient operating temperature –10°C to +60°C (at ambient humidity of 60% max.) (with no icing or condensation) Ambient operating humidity 80% max. (for +5°C to +35°C) Weight Approx. 7g (for pin plunger models)

  • SPST-NO NO COM Reed switch Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately) Refer to "Basic Switch Common Accessories"

D2RV Miniature Basic Switch D R V Terminals/Appearances (Unit:mm) Mounting Holes (Unit: mm) Dimensions (Unit: mm) /Operating Characteristics Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). 5.4 15.9 (10) 2.4 dia. 1.3 dia. 3.2 6.3 t=0.5 2-Solder terminals 4.8 10.3±0.1 2-3.1 dia. mounting holes or M3 screw holes 22.2±0.1 PT OP 2.8 5.4 15.9 (10) 2.8 1 27.8 3.1+0.13 −0.03 3.1+0.13 dia. holes−0.03 22.2±0.1 20.2±0.25 3.4±0.15 dia. 10.3±0.1 A 10.3 2.8 R1.5 4.3 5.15

  • Pin Plunger D2RV-E D2RV D2RV-G Model Operating characteristics D2RV-E D2RV D2RV-G Operating Force OF Max. 0.25 N {25 gf} 0.49 N {50 gf} 0.98 N {100 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 1.6 mm 0.6 mm 0.8 mm Operating Position OP 14.4±0.6 mm PT OP 5.4 4.3 15.9 (10) 2.8 1 27.8 3.1+0.13 −0.03 3.1+0.13 dia. holes−0.03 22.2±0.1 22.1 3.4±0.15 dia. 10.3±0.1 A 5.15 10.3 2.8 * Stainless-steel lever 8.1t=0.5 *
  • Short Hinge Lever D2RV-L11 D2RV-L11G Model Operating characteristics D2RV-L11 D2RV-L11G Operating Force OF Max. 0.49 N {50 gf} 0.98 N {100 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 1.8 mm 0.4 mm 1.0 mm Operating Position OP 15.0±0.6 mm PT OP 5.4 15.9 (10) 2.8 1 27.8 3.1+0.13 −0.03 3.1+0.13 dia. holes−0.03 22.2±0.1 35.6±0.8 3.4±0.15 dia. 10.3±0.1 A 10.3 2.8 * Stainless-steel lever 8.1t=0.5 * 4.3 5.15
  • Hinge Lever Models D2RV-L D2RV-LG Model Operating characteristics D2RV-L D2RV-LG Operating Force OF Max. 0.25 N {25 gf} 0.49 N {50 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 4.0 mm 1.0 mm 1.6 mm Operating Position OP 14.4±1.2 mm PT OP 5.4 15.9 (10) 2.8 1 27.8 3.1+0.13 −0.03 3.1+0.13 dia. holes−0.03 22.2±0.1 32.6±0.8 3.4±0.15 dia. 10.3±0.1 A 10.3 2.8 * Stainless-steel lever 8.1 t=0.5 *R3.5 4.3 5.15
  • Simulated Roller Lever Models D2RV-L13 D2RV-L13G Model Operating characteristics D2RV-L13 D2RV-L13G Operating Force OF Max. 0.25 N {25 gf} 0.49 N {50 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 4.0 mm 1.0 mm 1.6 mm Operating Position OP 18.1±1.2 mm

D2RV Miniature Basic Switch D R V Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). Precautions ★Please refer to "Basic Switches Common Precautions" for correct use.

  • Handling Do not drop the Switch or apply strong shock. It may result in internal mechanism damages and may deteriorate the characteristics of the inner Reed Switch.
  • Effect of the External Vibration When a vibration of 1 kHz or higher is applied, note that false switching operations may occur due to resonant frequency, even with a low acceleration.
  • Soldering  Terminal connections Complete the soldering at the iron tip temperature between 250 to 350°C (60W) within 5 seconds, and do not apply any external force for 1 minute after soldering. Apply minimum amount of flux required. It may result in contact failure once the flux penetrates into the internal part of the Switch.
  • Effect of the External Magnetic Fields  If two or more switch units are closely installed, mutual interference due to the fringing field will occur, resulting in malfunction. Be sure to keep the gap between the switch units 8 mm or more.  If you install the switch unit on the iron plate, each operating characteristic will change. Therefore, confirm that the interval between the switch units should be 2 mm or more.  Do not use the switch in some area where a strong external magnetic field would be applied, otherwise malfunction will be caused.  Use nonmagnetic brass or stainless steel (SUS304 alloy) screws for installation. Do not use any iron screw. PT OP 5.4 15.9 (10) 2.8 1 27.8 3.1+0.13 −0.03 3.1+0.13 dia. holes−0.03 22.2±0.1 3.4±0.15 dia. 10.3±0.1 10.3 2.8 8.1 5.15 4.8 dia.×4.8 *2 A t=0.5 *1 20.1 *1. Stainless-steel lever *2. Polyacetal resin roller
  • Short Hinge Roller Lever Models D2RV-L22 D2RV-L22G Model Operating characteristics D2RV-L22 D2RV-L22G Operating Force OF Max. 0.49 N {50 gf} 0.98 N {100 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 1.8 mm 0.4 mm 1.0 mm Operating Position OP 20.4±0.6 mm PT OP 5.4 15.9 (10) 2.8 1 27.8 3.1+0.13 −0.03 3.1+0.13 dia. holes−0.03 22.2±0.1 3.4±0.15 dia. 10.3±0.1 2.8 10.3 4.8 dia.×4.8 *2 *1. Stainless-steel lever *2. Polyacetal resin roller 8.1 34±0.8A t=0.5 *1 5.15
  • Hinge Roller Lever Models D2RV-L2 D2RV-L2G Model Operating characteristics D2RV-L2 D2RV-L2G Operating Force OF Max. 0.25 N {25 gf} 0.49 N {50 gf} Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 4.0 mm 1.0 mm 1.6 mm Operating Position OP 19.9±1.2 mm Cautions Correct Use

D2RV Miniature Basic Switch D R V  Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on live s and property if used improperly. M ake sure th at the r atings and perform ance ch aracteristics of the prod uct provide a m argin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. B056-E1-04 0812(0207)(O) Note: Do not use this document to operate the Unit.