n Super compact switch weighing only 0.3 g. Ideal for reducing equipment weight n Angle terminal allows operation from the side when mounted to a PCB n Despite its compact size, the snap action mecha- nism gives it superior electrical characteristics n Silver-plated contact. Gold-plated contact also available for loads under 50 mA n Ideal for use on equipment with stringent space and reliability requirements, such as in compact audio equipment, optical devices, and communi- cations equipment

Ordering Information

Pin Leaf Straight Left-angle Right-angle plunger lever terminal terminal terminal Part Number Actuator Contact Straight Terminal Left-angle Terminal Right-angle Terminal Pin plunger Silver-plated (Ag-P) D2MQ-1 D2MQ-1-TL D2MQ-1-TR Gold-plated (Au-P) D2MQ-1-105 — — Leaf lever Silver-plated (Ag-P) D2MQ-1L D2MQ-1L-TL D2MQ-1L-TR Gold-plated (Au-P) D2MQ-1L-105 — — Specifications Ratings Electrical ratings Ag-Plated contact: 50 to 500 mA, 30 VDC (resistive load) Au-Plated contact: 5 to 50 mA, 30 VDC (resistive load) Inrush current NC: 0.5 A max. (Ag-P), 0.05 A max. (Au-P) NO: 0.5 A max. (Ag-P), 0.05 A max. (Au-P) n CONTACT FORM Note: The angle of the terminal illustration above is from the side of the arrow shown on the right. SUBMINIATURE

Operating speed 0.1 mm to 0.5 m/second (0.004 to 19.7 in/second) at pin plunger Operating frequency Mechanical 60 operations per minute Electrical 20 operations per minute Contact resistance 100 m Ω max. (initial) Insulation resistance 100 M Ω min. (at 250 VDC) Dielectric strength 500 VAC, 50/60 Hz for 1 minute between terminals of same polarity

500 VAC, 50/60 Hz for 1 minute between current-carrying metal part and ground

Vibration Malfunction durability 10 to 55 Hz, 1.5 mm double amplitude Shock Mechanical durability 1,000 m/s 2 min, (approx. 100 g min.) Malfunction durability 300 m/s2 min. (approx. 30 g min.) Ambient temperature Operating -15 ° to 70°C (with not condensation) Humidity 35% to 85% RH Service life Mechanical 30,000 operations min. (at full OT value) Electrical 10,000 operations min. (at full OT value) Weight Approx. 0.3 g Characteristics Note: Data shown are of initial value. n CHARACTERISTIC DATA Mechanical service life Electrical service life Number of operations (x103) Number of operations (x103) Overtravel (mm) Switching current (A)

D2MQ-1 (Straight terminal) D2MQ-1-TL (Left-angle terminal) D2MQ-1-TR (Right-angle terminal) D2MQ-1-105 (Straight terminal) Dimensions Unit: mm (inch) Operating characteristics OF max. 120 g RF min. 20 g PT max. 0.4 mm (0.016 in) OT min. 0.1 mm (0.004 in) MD max. 0.1 mm (0.004 in) OP 5.7 ± 0.2 mm (0.22 ± 0.01 in) Leaf lever D2MQ-1L (Straight terminal) D2MQ-1L-TL (Left-angle terminal) D2MQ-1L-TR (Right-angle terminal) D2MQ-1L-105 (Straight terminal) Operating characteristics OF max. 60 g RF min. 8 g PT max. 2.4 mm (0.09 in) OT min. 0.3 mm (0.01 in) MD max. 0.7 mm (0.03 in) FP* max. 9.6 mm (0.38 in) OP 6.7 ± 0.5 mm (0.26 ± 0.02 in) n TERMINALS Straight terminal Left-angle terminal Right-angle terminal Note: Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions. *Free position

Mount firmly using M1.4 screws and 1 kg-cm tightening torque. Mounting hole matching dimensions When mounting onto a metal body, always install a separator between the switch and the mounting panel. Design the insulation separator (made up of hard material) into the shape shown below. Separator shape n SOLDERING Holding the switch at the free position, solder the lead wire to its terminal within 3 seconds, using a soldering iron rated at less than 15 W with a tip temperature of less than 280°C. Excess wattage or prolonged heating can deteriorate the electrical characteristics of the switch. n OPER ATION Set the operating force of the pushbutton and leaf lever at less than twice the OF standard value. Always make the OT value larger than the specification value. Do not change the operating position of the actuator. Do not operate at extremely slow speed; also do not use the switch with its pushbutton located between the free position and the operating position. Mount the pin pushbutton type in such a way that the stroke of the pushbutton and the stroke of the operating control overlap on a vertical line. Do not operate the switch roughly as it may deteriorate the functions of the switch. Do not apply excessive force to the actuator of the leaf lever type along its operating direction, opposite to its operating direction, or in the lateral direction.