Technical content

www.hygroup.com.tw D2KB05 THRU D2KB10 Features D3K

  • Glass passivated chip
  • Low forward voltage drop RoHS
  • Ideal for printed circuit board COMPLIANT
  • High surge current capability
  • Meet UL flammability classification 94V-0 Mechanical Data
  • Polarity: Symbol marked on body
  • Mounting position: Any Note: Products with logo or are made by HY Electronic (Cayman) Limited.

Applications

  • General purpose use in AC/DC bridge full wave rectification, for SMPS, lighting ballaster, adapter, etc. Maximum Ratings and Electrical Characteristics Rating at 25℃ ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. Characteristics Symbol D2KB05 D2KB1 D2KB2 D2KB4 D2KB6 D2KB8 D2KB10 UNIT Maximum Repetitive Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 V Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 V Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 V Maximum Average Forward Rectified Current @TC=138℃ I(AV) A Peak Forward Surge Current, 8.3mS Single Half Sine-Wave, Superimposed on Rated Load (JEDEC Method) I2t Rating for Fusing (t<8.3mS) I2t A2s Peak Forward Voltage per Diode at 2.0A DC VF V Typical Thermal Resistance to Ambient (without heatsink) RθJA ℃/W Typical Thermal Resistance to case (with heatsink (Note2) ) RθJC ℃/W Typical Thermal Resistance to lead (without heatsink) RθJL ℃/W Maximum DC Reverse Current at Rated @TJ=25℃ DC Blocking Voltage per Diode @TJ=125℃ Operating Junction Temperature Range TJ ℃ Storage Temperature Range TSTG ℃ Notes: 1. Device mounted on 50mm*50mm*1.6mm Cu plate heatsink. 2. The typical data above is for reference only Rev. 11, 18-May-2020 Glass Passivated Bridge Rectifiers 500 -55 to +150 -55 to +150 Reverse Voltage - 50 to 1000 Volts Forward Current - 2.0 Amperes Package Outline Dimensions in Inches (Millimeters) Pb IFSM IR A μA 1.05 1.5 17.5 All d ata sheet.com

Rating and Characteristic Curves D2KB05 THRU D2KB10 The curve above is for reference only. D2KB*-U-00/99/92-00/01 Rev. 11, 18-May-2020 0.5 1.5 2.5 0 50 100 150 Fig. 1 - Forward Current Derating Curve A verage Forward Current (A) 0.1 TJ=25°C TJ=75°C TJ=100°C TJ=125°C Pulse Width 300uS 2%Duty Cycle Fig. 4 - Typical Forward Characteristics I nstantaneous Forward Current (A) Instantaneous Forward Voltage (V) Fig. 2 - Maximum Non-Repetitive Surge Current Number of Cycles at 60Hz P eak Forward Surge Current (A) 1 10 100 8.3mS Single Half-Sine-Wave (JEDEC METOD) I nstantaneous Reverse Current (uA) Fig. 3 - Typical Reverse Characteristics 0.1 100 1000 20 40 60 80 100 TJ=25°C TJ=75°C TJ=100°C TJ=125°C Percent of Rated Peak Reverse Voltage (%) Case Temperature (℃) TJ=150°C All d ata sheet.com

ALL specifications and data are subject to be changed without notice to improve reliability function or design or other reasons. HY makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co- tinuing production of any product. To the maximum extent permitted by applicable law, HY disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d- amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch- antability. Statements regarding the suitability of products for certain types of applications are based on HY’s knowledge of typical require- ments that are often placed on HY products in generic applications. Such statements are not binding statements about the suitabi- lity of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.Parameters provided in datasheets and specific- ations may vary in different applications and performance may vary over time. All operating parameters, including typical paramet- ers, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify HY’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, HY products are not designed for use in medical, life-saving, or life-sustaining applicati- ons or for any other applications in which the failure of the HY product could result in personal injury or death. Customers using or selling HY products not expressly indicated for use in such applications do so at their own risk.Please contact authorized HY pers- onnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of HY. Product names and markings noted herein may be trademarks of their respective owners. Rev. 11, 18-May-2020 Disclaimer All d ata sheet.com