D2FC-F-7N OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
EiFor-Receipt I For reference Date of Issue : Nov.6.2007 TO: BYD OMRON CORPORATION OMRON KURAYOSHI Co., Ltd. Product Engineering Group, 1st__ Product Department Prepared by Checked by Approved by RoHS directive Compliant part WN. Aras ne fom ale. PRODUCT SPECIFICATIONS Description : Ultra Sub Miniature Basic Switch Part Number : D2FC-F-7N Product Specifications No. : 3710448-0 A M™@ Please return _—_ copy (copies) of this specification sheet signifying your acceptance by stamping below. Due date : ——— Description : Part number : Receipt Stamp (For receipt purpose only) Submitted Stamp SUBMITTED NOY. - 6. 2007 Gy. OMRON <2 SS Row coro MPlease accept handling of this specification sheet as for reference use if not reply received. Distribution P| Cony | Customer || sales¢ |
No. 3710448-0 A (1/4) 1. Safety Standard
1.1 Approved standard —_
1.2 File No. _ 2. Structure 2.1 Outline drawing No. — 9470077-3
2.2 Mechanism Snap action
23 Contact form Single pole single throw (SPST) C-NO
24 Protective structure IP40 Conforming to ¥IEC standard —_*IEC : International Electrotechnical Commission
25 Terminal For PCB board
- Mechanical Characteristics
3.1 Operating characteristics (Initial value)
[ [tem Abbr. | Unit [Specification value | [1 [Oneatngtace | OF | N | Oaatoam | | 2 | Releasingforce | RF | ON | Min 024 | [3 [Preto | PT | wm | ao | 4 |Overtavel | OT | mm | Min oz [5 [Movement diffrent | MD | mm | Max 012 + [6 [Operating poston | OP | mm | —oax02——| [7 [FeePosten | [mm | ae i
3.2 Malfunction vibration
Open contact duration shall be Imsec. max. when the following vibration is applied; Amplitude : 1.5mm Frequency : 10 to 55Hz Cycle : 3 to 5 minutes Direction : X, Y and Z axis Time : 10 minute per axis
3.3 Vibration durability
No electrical or mechanical defect after the following vibration is applied; Amplitude : 1.5mm Frequency : 10 to 55Hz Cycle : 3 to 5 minutes Direction : X, Y and Z axis Time : 2 hours per axis
3.4 Malfunction shock
Open contact duration shall be Imsec. max. when the following shock is applied; Shock : Max. 300m/s? Direction : X, Y and Z axis Time : 3 times per axis
3.5 Shock durability
No electrical or mechanical defect after the following shock is applied; Shock : Max. 1000m/s* Direction : X, Y and Z axis Time : 10 times per axis Condition common to Section 3.2 and 3.4 Applied voltage :DC5V — Applied current : 100mA Actuator position : Total travel position(detected by oscilloscope)
3.6 Actuator strength
No electrical or mechanical defect when the following force is applied to the actuator, Direction : Actuator operation direction Force : 10 times of the specified operating force (OF) 7.4N Time : 1 minute
No. 3710448-0 A (2/4)
3.7 Permissible operating frequency
200 operations/minute max.
3.8 Permissible operating speed
4.1 Switching capacity ratings
42 Contact resistance (at total travel position TTP)
Initial value 100m _ max. at 6VDC 0.1A by voltage drop method
43 Insulation resistance, Dielectric strength
Mase | Insulation resistance Dielectric strength Remark Measuring part (DC500V megger) (80/60Hz for 1 minute) | Between terminals of the same polarity | 100M@ Min | 600 |
44 Degree of protection against electric shock
Class I (protecting by ground in addition to basic insulation for shock prevention)
45 Proof tracking index (PTI)
175 level (Classification according to UL Yellow Book : PLC level 3. 175 SCTI<250) 5. Environmental Characteristics
5.1 Heat resistance
No electrical or mechanical defect at the standard test condition after leaving at room temperature and humidity for about 1 hour, after soaking under the ambience of 652°C for 96 hours.
5.2 Cold resistance
No electrical or mechanical defect at the standard test condition after leaving at room temperature and humidity for about 1 hour, after soaking under the ambience of -25++2°C for 96 hours. There shall be no icing at a lower temperature range.
5.3 Humidity resistance
No electrical or mechanical defect at the standard test condition after leaving at room temperature and humidity for about 1 hour, after soaking under the ambience of 40-+2°C and 90 to 95%RH for 96 hours.
5.4 Temperature cycle resistance
No electrical or mechanical defect at the standard test condition after 1 cycle of -40+2°C and 85+2°C soaking (48 hours at each temperature) 6. Usage Environment
6.1 Ambient temperature range
-25 to +65°C (Humidity : 60%RH Max., No dewing or icing)
6.2 Ambient humidity range
‘85%RH Max. (at +5 to +35°C, No dewing or icing) 7. Durability No electrical or mechanical defect at the standard test condition when switching the rated load by 5,000,000 operations at the operating frequency of 120 operations/minute at the stroke of the specified OT value. The contact resistance shall be 1002 max. and the dielectric strength between terminals of the same polarity shall be excluded. 8. Standard Test Condition and Criteria
8.1 Standard test condition
Temperature :20+15°C Humidity : 65-+20%RH
8.2 Definition of “No electrical or mechanical defect”
Operating characteristics : Not exceeding ++20% of the specification value Contact resistance : 4 times the initial specification value Max. Insulation resistance : 10M Min. Dielectric strength : Meeting the specification value
No. 3710448-0 A (3/4) 9. Precautions
9.1 Stroke setting for switch
*Setting an operating dog in the direction where the actuator moves and detaching the dog from the actuator completely when the switch is at the free position (FP). *The overtarvel (OT) (0.2mm) is appropriate for the switch stroke setting. “Avoiding an impact operation as much as possible as it can cause life deterioration.
92 Soldering work
“Do the soldering work under the conditions specified below. | Contin | Standard | Remarks Manual soldering 350°C 30 to 40W | Do not apply an excessive force to the terminals 3 seconds Max. during the soldering work. ‘Automated soldering | 260°C The soldering time should be 3 seconds max. when the switch 5 seconds Max. is mounted on a double-sided PCB (through-hole PCB). Control the liquid level of flux and solder not to exceed PCB. Note : Do not apply an excessive wattage or too long heating, or do not operate the switch for 1 minite after heating. Otherwise, the switch characteristics may be deteriorated Be sure to apply only the minimum required amount of flux. The switch may have a contact failure if flux enters inside the switch.
9.3 Usage/storage environment for switch
“Avoiding the location where a corrosive gas is generated or temperature changes suddenly, the ambience of high temperature or humidity, dusts and others. “It is recommended that the switch should be inspected before use if it is stored for 3 to 6 months after the production, depending on the location.
9.4 Switch mounting
Referring to the figure on the right for mounting-hole processing drawing. 31.2 10. Warranty
10.1 Content
(1) Warranty period The warranty period for an OMRON product is one year from either the date of purchase or the date on which the OMRON product is delivered to the specified location. (2) Extent of warranty If an OMRON product is subject to a failure for which OMRON is responsible during the warranty period, either a replacement product will be provided or the defective product will be repaired free of charge at the place of purchase. This warranty, however, will not cover the problems that occur as a result of any of the following: a) Using the OMRON product under conditions or in an environment not described in catalogs or in the specifications, or not operating the OMRON product according to the instructions contained in catalogs or in the specifications b) Problem caused by something other than the OMRON product. c) Modifications or repairs performed by a party other than OMRON. d) Using the OMRON product for other than its designed purpose. e) Problems that could not have been foreseen with the level of science and technology that existed at the time the OMRON product was shipped. f) Problems caused by an Act of God or other circumstances for which OMRON is not responsible. This warranty covers only the OMRON product itself. It does not cover any other damages that may occur directly or indirectly as a result of a problem with the OMRON product
10.2 Limitations of liability
OMRON shall not be responsible for special, indirect, or consequential damages originating in an OMRON product.
No. 3710448-0 A (4/4)
10.3 Applicable conditions
(1) When using OMRON products in combination with other products, it is the user’ s responsibility to confirm compliance with all applicable standards and regulations. It is also the user’ s responsibility to confirm the suitability of the OMRON products for the system, devices, and equipment that are being used. OMRON accepts no responsibility for the suitability of OMRON products used in combination with other products. (2) When using OMRON products in any of the following applications, consult an OMRON representative and check specifications to allow sufficient leeway in ratings and performance, and to implement suitable safety measures, such as safety circuits, to minimize danger in the event of an accident. 1) Outdoor applications, applications with potential for chemical contamination or electrical interference, or application under conditions or environments not described in catalogs. 2) Nuclear control systems, railroad systems, aviation systems, combustion systems, medical equipment, amusement machines, or equipment regulated by government or industrial standards. 3) Other systems, machines, and equipment that may have a serious influence on human life and property. 4) Equipment requiring a high level of reliability, such as gas, water, or electrical supply systems, and systems that operate 24 hours a day. 5) Other applications requiring a high level of safety, corresponding to items 1) to 4), above. (3) When OMRON products are used in an application that could pose significant risk to human life or property, the overall system must be designed so that the required safety can be ensured by providing notice of the danger and incorporating redundancy into the design. Make sure that OMRON products are appropriately wired and mounted to serve their intended purpose in the overall system. (4) Application examples provided in catalogs are for reference only. Confirm functionality and safety before actually using the devices and equipment. (8) To prevent unexpected problems from arising due to the OMRON product being used incorrectly by the customer or any other party, make sure that you understand and carefully observe all of the relevant prohibitions and precautions, (6) Each rating and performance value given in catalogs etc. is the value in an independent examination, and does not guarantee simultaneously the compound conditions of each rating and performance value. (7) Do not use the OMRON Product for automotive applications (including two-wheeled motor vehicle.) Please consult with your OMRON representative if the OMRON Product is used in the automotive applications.
104 Changes of specifications
Specifications and accessories to the products in catalogs may be changed as needed to improve the products or for any other reason. Check with your OMRON representative for the actual specifications for OMRON products at the time purchase.
10.5 Treatment of the specifications for reference
When these specifications are issued for reference, please consult with your OMRON representative before actually using the specifications and confirm the latest specifications for the OMRON product.
10.6 Extent of service
The price of an OMRON product does not include service costs, such as dispatching technical staff. If you wish for service, please consult with your OMRON representative.
10.7 Effective term
These specifications will be invalid when there is not retum or an order for one year from the date of issue. a LO a a a nO |_A_| 070717 |Newyprepared Nai | Yama _|
- OPERATING CHARACTERISTICS | a OPERATING FORCE 0. 44~0. 74N OP Fs OPERATING POSITION —— wl 2.9 A S| a Z 1mA 6VDC (RESISTIVE LOAD) d 23 4 3. CONTACT FORM : g EE] 8 COM-NO " wo) ral a t Ke) am Ww ia) ES C_J a | © ira \\ an | Note. Dummy termina! should not be Le th H H connected to any circit. a Pa WN so tH IL 6-Maxo. 05. cl 4 LC 2-41. 4°8 HOLE Cc fas) COM NO DUMMY TERM] NAL \\TERMI NA‘ TERMINAL [ate a Joe Se TYPE D2FC-F-7N pL ns 5 tT ULTRA SUBMINIATUE BASIC SWITCH Jp pf froverancesoesioneo) cuecken lapproven OUTLINE DRAWING UNLESS , ANGLE ee DRWG [| __ | |specteten [JUL 17 07 Tubt7707 a 9470077-3 A [eva] oare fee contenral eve no [srw | * 0. 4 |W ARAL Pt lamach 14 Qiitniente Reserves omron ha