D2F_V01 OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
D F D2F Ultra Subminiature Basic Switch Ultra Subminiature Basic Switch with plenty of terminal variations
- Incorporating a snapping mechanism made with two highly precise split springs that ensures long durability.
- Using insertion molded terminals that prevents flux penetration.
- In addition to self-clinching PCB, left-angled, right-angled terminals, 2 types of soldering terminals are available.
- Lineup of 5A type for high load applications. RoHS Compliant Model Number Legend D2F- @@@@ 1. Ratings None : 125 VAC 3A
125 VAC 1A (Low operating force)
01 : 30 VDC 0.1A 5 : 250 VAC 5A 2. Maximum Operating Force (OF) None : 1.47 N {150 gf} F : 0.74 N {75 gf} Note. The given values are for pin plunger models only. 3. Actuator None : Pin plunger L : Hinge lever L2 : Hinge Roller Lever L3 : Simulated roller lever (R1.3) L30 : Simulated roller lever (R2.5) 4. Terminals None : PCB terminals (Straight) -T : Self-clinching PCB terminals -A : PCB terminals (Right-angled) -A1 : PCB terminals (Left-angled) -D3 : Solder terminals -D : Compact solder terminals 1 2 3 4
D2F Ultra Subminiature Basic Switch D F List of Models * OF are value for Pin plunger. Contact Form
- SPDT Contact Specifications * Please refer to " Using Micro Loads" in "Precautions" for more information on the minimum applicable load. Ratings Note. The above rating values apply under the following test conditions. (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5% (3) Operating frequency: 30 operations/min Approved Safety Standard The items shown in the "List of Models" above are not standard approved models. Consult your OMRON sales representative for specific models with standard approvals. UL (UL1054) /CSA (CSA C22.2 No.55) Ratings 3 A 1 A 0.1 A 5 A Maximum Operating Force (OF) * General Purpose
1.47 N {150 gf}
0.74 N {75 gf}
1.47 N {150 gf}Actuator Ter minals
Pin plunger PCB terminals (Standard) D2F D2F-F D2F-01 D2F-01F D2F-5 Self-clinching PCB terminals D2F-T D2F-F-T D2F-01-T D2F-01F-T PCB terminals (Right-angled) D2F-A D2F-F-A D2F-01-A D2F-01F-A PCB terminals (Left-angled) D2F-A1 D2F-F-A1 D2F-01-A1 D2F-01F-A1 Solder terminals D2F-D3 D2F-F-D3 D2F-01-D3 D2F-01F-D3 Compact solder terminals D2F-D D2F-F-D D2F-01-D D2F-01F-D Hinge lever PCB terminals (Standard) D2F-L D2F-FL D2F-01L D2F-01FL D2F-5L Self-clinching PCB terminals D2F-L-T D2F-FL-T D2F-01L-T D2F-01FL-T PCB terminals (Right-angled) D2F-L-A D2F-FL-A D2F-01L-A D2F-01FL-A PCB terminals (Left-angled) D2F-L-A1 D2F-FL-A1 D2F-01L-A1 D2F-01FL-A1 Solder terminals D2F-L-D3 D2F-FL-D3 D2F-01L-D3 D2F-01FL-D3 Compact solder terminals D2F-L-D D2F-FL-D D2F-01L-D D2F-01FL-D Hinge roller lever PCB terminals (Standard) D2F-L2 D2F-FL2 D2F-01L2 D2F-01FL2 Self-clinching PCB terminals D2F-L2-T D2F-FL2-T D2F-01L2-T D2F-01FL2-T PCB terminals (Right-angled) D2F-L2-A D2F-FL2-A D2F-01L2-A D2F-01FL2-A PCB terminals (Left-angled) D2F-L2-A1 D2F-FL2-A1 D2F-01L2-A1 D2F-01FL2-A1 Solder terminals D2F-L2-D3 D2F-FL2-D3 D2F-01L2-D3 D2F-01FL2-D3 Compact solder terminals D2F-L2-D D2F-FL2-D D2F-01L2-D D2F-01FL2-D Simulated roller lever (R1.3) PCB terminals (Standard) D2F-L3 D2F-FL3 D2F-01L3 D2F-01FL3 D2F-5L3 Self-clinching PCB terminals D2F-L3-T D2F-FL3-T D2F-01L3-T D2F-01FL3-T PCB terminals (Right-angled) D2F-L3-A D2F-FL3-A D2F-01L3-A D2F-01FL3-A PCB terminals (Left-angled) D2F-L3-A1 D2F-FL3-A1 D2F-01L3-A1 D2F-01FL3-A1 Solder terminals D2F-L3-D3 D2F-FL3-D3 D2F-01L3-D3 D2F-01FL3-D3 Compact solder terminals D2F-L3-D D2F-FL3-D D2F-01L3-D D2F-01FL3-D Simulated roller lever (R2.5) PCB terminals (Standard) D2F-L30 D2F-FL30 D2F-01L30 D2F-01FL30 Self-clinching PCB terminals D2F-L30-T D2F-FL30-T D2F-01L30-T D2F-01FL30-T PCB terminals (Right-angled) D2F-L30-A D2F-FL30-A D2F-01L30-A D2F-01FL30-A PCB terminals (Left-angled) D2F-L30-A1 D2F-FL30-A1 D2F-01L30-A1 D2F-01FL30-A1 Solder terminals D2F-L30-D3 D2F-FL30-D3 D2F-01L30-D3 D2F-01FL30-D3 Compact solder terminals D2F-L30-D D2F-FL30-D D2F-01L30-D D2F-01FL30-D COM NO NC Item Model D2F models D2F-5 models D2F-01 models Contact Specifications Crossbar Material Sil ver alloy Gold alloy Gap (standard value) 0.25 mm Minimum applicable load (see note) * 100 mA at 5 VDC 1 mA at 5 VDC Model Maximum Operating Force (OF) Rated voltage D2F models D2F-01 models D2F-5 models Resistive load
125 VAC 3 A 1 A - -
30 VDC 2 A 0.5 A 0.1 A -
250 VAC - - 5 A
Rated voltage Model D2F (General-purpose) D2F (Low operating force) D2F-01
125 VAC 3 A 1 A -
30 VDC 2 A 0.5 A 0.1 A
D2F Ultra Subminiature Basic Switch D F Characteristics Note. The data given above are initial values. *1. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1ms max. *2. For testing conditions, cons ult your OMRON sales representative. Terminals/Appearances (Unit: mm) Mounting Holes (Unit: mm) Model D2F-01 models D2F models D2F-5 models Item 0.74 N (Low operating force) 1.47 N (General-purpose) 1.47 N (General-purpose) Permissible operating speed Pin plunger models: 1 mm to 500 mm/s, Lever models: 5 mm to 500 mm/s Permissible operating frequency Mechanical Pin plunger models: 200 operations/min, Lever models: 100 operations/min Electrical 30 operations/min Insulation resistance 100 M Ω min. (at 500 VDC with insulation tester) Contact resistance (initial value) 100 m Ω max. 50 m Ω max. 30 m Ω max. Dielectric strength Between terminals of the same polarity 600 VAC 50/60 Hz for 1min Between current-carrying metal parts and ground 1,500 VAC 50/60 Hz for 1min Between each terminal and non-current-carrying metal parts 1,500 VAC 50/60 Hz for 1min Vibration resistance * 1 Malfunction 10 to 55 Hz, 1.5-mm do uble amplitude Shock resistance Durability 1,000 m/s 2 {approx. 100G} max. Malfunction * 1 300 m/s 2 {approx. 30G} max. Durability * 2 Mechanical 1,000,000 operations min. (60 operations/min) Electrical 100,000 operations min. (30 operations/min) 30,000 operations min. (30 operations/min) 10,000 operations min. (30 operations/min) Degree of protection IEC IP40 Ambient operating temperature -40°C to +85°C (at ambient humidity 60% max.) (with no icing or condensation) Ambient operating humidity 85% max. (for +5°C to +35°C) Weight Approx. 0.5 g (pin plunger models)
- PCB terminals (Straight) ●Self-clinching PCB terminals <PCB Mounting Dimensions (Reference)>
- PCB terminals (Right-angled) ●PCB terminals (Left-angled)
- Solder terminals ●Compact solder terminals 5.8±0.15 0.4 1.5 3.5 0.9 5.085.08 12.8±0.15 6.5±0.1 3.15 5.8±0.15 1.6±0.15 1.5 0.4±0.05 1.25±0.15 1.5 3.4 0.9 5.085.08 6.5±0.1 3.15 12.8±0.15 5.8±0.15 3-1.2 dia. holes 5.08±0.1 12.8±0.15 5.8±0.15 2.6±0.2 0.4 3.1±0.2 1.5 0.9 5.085.08 6.5±0.1 3.15 12.8±0.15 5.8±0.15 2.6±0.2 0.4 3.1±0.2 1.5 0.9 5.085.08 6.5±0.1 3.15 12.8±0.15 5.8±0.15 0.4 1.5 3.5 2.2 1.2 5.085.08 6.5±0.1 3.15 0.5 12.8±0.15 5.8±0.15 0.4 1.5 2.4 1.6 5.085.083−0.8 dia. holes 12.8±0.15 6.5±0.1 3.15 2-2 dia. mounting holes 6.5±0.15
D2F Ultra Subminiature Basic Switch D F Dimensions (Unit: mm) /Operating Characteristics The following illustrations and drawings are for D2F models with PCB terminals (straight). Self-clinching, solder, compact solder, and right-angled, left angled terminals are omitted from the following drawings. Refer to the previous page for these terminals. When ordering, replace @ with the code for the terminal that you need. See the "List of Models" for available combinations of models. Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). 12.7 5.7 2.95.2 5.8±0.15 0.4 PT OP5 2.2+0.12 dia.0 2+0.12 dia. holes01.2 2+0.12 A
- Pin Plunger Models D2F-@ D2F-01@ D2F-F@ D2F-01F@ D2F-5 Operating Characteristics Model D2F-@ D2F-01@ D2F-5 D2F-F@ D2F-01F@ Operating Force OF Max. Releasing Force RF Min.
0.20 N {20 gf}
0.05 N {5 gf}
Pretravel PT Max. Overtravel OT Min. Movement Differential MD Max. 0.5 mm 0.25 mm 0.12 mm 0.5 mm 0.25 mm 0.12 mm Operating Position OP 5.5±0.3 mm
- Hinge Lever Models D2F-L@ D2F-01L@ D2F-FL@ D2F-01FL@ D2F-5L Operating Characteristics Model D2F-L@ D2F-01L@ D2F-5L D2F-FL@ D2F-01FL@ Operating Force OF Max. Releasing Force RF Min.
0.78 N {80 gf}
0.25 N {25 gf}
0.02 N {2 gf}
Overtravel OT Min. Movement Differential MD Max. 0.55 mm 0.5 mm 0.55 mm 0.5 mm Free Position FP Max. Operating Position OP 10 mm 6.8±1.5 mm (10.8) 12.8 t=0.3 * * Stainless-steel lever OP FP A
- Simulated Roller Lever Models (R1.3) D2F-L3@ D2F-01L3@ D2F-FL3@ D2F-01FL3@ D2F-5L3 Operating Characteristics Model D2F-L3@ D2F-01L3@ D2F-5L3 D2F-FL3@ D2F-01FL3@ Operating Force OF Max. Releasing Force RF Min.
0.39 N {40 gf}
Overtravel OT Min. Movement Differential MD Max. 0.5 mm 0.45 mm 0.5 mm 0.45 mm Free Position FP Max. Operating Position OP 13 mm 8.5±1.2 mm (7.5) R1.3 3 * Stainless-steel lever OP FP 2.1 t=0.3 * A 12.7
- Simulated Roller Lever Models (R2.5) D2F-L30@ D2F-01L30@ D2F-FL30@ D2F-01FL30@ Operating Characteristics Model D2F-L30@ D2F-01L30@ D2F-FL30@ D2F-01FL30@ Operating Force OF Max. Releasing Force RF Min.
0.54 N {55 gf}
0.04 N {4 gf}
0.3 N {31 gf}
Overtravel OT Min. Movement Differential MD Max. 0.5 mm 0.5 mm 0.5 mm 0.5 mm Free Position FP Max. Operating Position OP 12.6 mm 9.5±1.0 mm t=0.3 *3.3 R2.5 * Stainless-steel lever OP FP A 12.7
D2F Ultra Subminiature Basic Switch D F Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). Precautions ★Please refer to "Basic Switches Common Precautions" for correct use.
- Soldering Terminal connection When soldering, make sure that the temperature of the soldering iron tip is not higher than 300°C, and complete the soldering within 3 seconds. Do not apply any external force for 1 minute after soldering. Soldering at an excessively high temperature or soldering for more than 3 seconds may deteriorate the characteristics of the Switch. Connecting to PCB terminal Boards When using automatic soldering baths, we recommend soldering at 260°C ±5°C within 5 seconds. Make sure that the liquid surface of the solder does not flow over the edge of the board. When soldering terminals manually, perform soldering within 3 seconds at iron tip temperature not higher than 350°C. Do not apply any external force for at least 1 minute after soldering. When applying solder, keep the solder away from the case of the Switch and do not allow solder or flux to flow into the case.
- Mounting Use M2 mounting screws with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.08 to 0.1 N·m {0.8 to 1 kgf·cm}.
- Using Micro Loads Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the following operating range, if inrush current occurs when the contact is opened or closed, it may increase the contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ60). (JIS C5003) The equation, λ60=0.5×10-6/operation, indicates that the estimated malfunction rate is less than operations with a reliability level of 60%.
- Hinge Roller Lever Models D2F-L2@ D2F-01L2@ D2F-FL2@ D2F-01FL2@ Operating Characteristics Model D2F-L2@ D2F-01L2@ D2F-FL2@ D2F-01FL2@ Operating Force OF Max. Releasing Force RF Min.
Overtravel OT Min. Movement Differential MD Max. 0.55 mm 0.5 mm 0.55 mm 0.5 mm Free Position FP Max. Operating Position OP 16.5 mm 13±2 mm (10) 412.8 t=0.3 *1 (4.6) *1. Stainless-steel lever *2. Polyacetal resin roller OP 4 FP 4.8 dia.×2.8 *2A Cautions Correct Use 2,000,000 Voltage (V) 1 10 100 1,000 Current (mA) 0.1 1 mA Operating range for general-load models D2F 16.6 mA0.16 mA 100 mA Operating range for micro load models D2F-01
D2F Ultra Subminiature Basic Switch D F Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not descri bed in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product p rovide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Cat. No. B036-E1-12 0318(0207)(O) Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb