forward-curved, dual-intake with housing (without flange) D2E133-AM47-65 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRB 590142 Nominal data Type D2E133-AM47-65 Motor M2E068-DF Phase 1~ 1~ Nominal voltage VAC 230 230 Frequency Hz 50 60 Method of obtaining data fa ml Valid for approval/standard CE CE Speed (rpm) min-1 1500 1800 Power consumption W 190 200 Current draw A 0.84 0.88 Capacitor µF 3 3 Capacitor voltage VDB 450 450 Capacitor standard S0 S0 Min. back pressure Pa 0 100 Min. back pressure inH2O 0 0.4 Min. ambient temperature °C -25 -25 Max. ambient temperature °C 35 25 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change Item no. 10511-5-9980 · ENU · Change 88055 · Approved 2016-05-30 · Page 1 / 5

forward-curved, dual-intake with housing (without flange) D2E133-AM47-65 Technical description Weight 3.5 kg Fan size 133 mm Rotor surface Unpainted Impeller material Sheet steel, galvanized Housing material Sheet steel, galvanized Motor suspension Motor mounted with brackets on one side Direction of rotation Clockwise, viewed toward rotor Degree of protection IP44; installation- and position-dependent Insulation class "B" Moisture (F) / Environmental (H) protection class H0 - dry environment Max. permitted ambient temp. for motor (transport/storage) + 80 °C Min. permitted ambient temp. for motor (transport/storage) - 40 °C Installation position Any Condensation drainage holes None Mode S1 Motor bearing Ball bearing Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) internally connected With cable Axial Protection class I (with customer connection of protective earth) Conformity with standards EN 60335-1; CE Item no. 10511-5-9980 · ENU · Change 88055 · Approved 2016-05-30 · Page 2 / 5

forward-curved, dual-intake with housing (without flange) D2E133-AM47-65 Product drawing 1 Cable PVC 4G 0.5 mm², 4x crimped splices Connection diagram U1 blue Z brown U2 black PE green/yellow Item no. 10511-5-9980 · ENU · Change 88055 · Approved 2016-05-30 · Page 3 / 5

forward-curved, dual-intake with housing (without flange) D2E133-AM47-65 Curves: Air performance 50 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 qv[m^3/h]750 700 650 600 550 500 450 400 350 300 250 200 150 100 50 0 qv[cfm] 450 400 350 300 250 200 150 100 50 0 p f s[Pa] 3803703603503403303203103002902802702602502402302202102001901801701601501401301201101009080706050403020100 pfs_E[IN H2O] Measurement: LU-105263-1 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. Measured values U V 230 230 230 230 f Hz n min-1 1500 1890 2310 2570 Pe W 190 164 141 118 I A 0.84 0.72 0.61 0.52 qv m3/h 710 640 460 295 pfs Pa 100 200 275 qv CFM 420 375 270 175 pfs inH2O 0.00 0.40 0.80 1.10 U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 10511-5-9980 · ENU · Change 88055 · Approved 2016-05-30 · Page 4 / 5

forward-curved, dual-intake with housing (without flange) D2E133-AM47-65 Curves: Air performance 60 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 qv[m^3/h]700 650 600 550 500 450 400 350 300 250 200 150 100 50 0 qv[cfm] 400 350 300 250 200 150 100 50 0 p f s[Pa] 460440420400380360340320300280260240220200180160140120100806040200 pfs_E[IN H2O] Measurement: LU-105265-1 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. Measured values U V 230 230 230 230 f Hz n min-1 1800 2310 2685 2945 Pe W 200 181 170 159 I A 0.88 0.78 0.74 0.70 qv m3/h 565 425 300 180 pfs Pa 100 200 300 375 qv CFM 335 250 175 105 pfs inH2O 0.40 0.80 1.20 1.51 U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 10511-5-9980 · ENU · Change 88055 · Approved 2016-05-30 · Page 5 / 5