MODEL NUMBERS AC CONTROL A1210 A1225 A1240 A2410 A2425 A2450 A2475 A2490 DC CONTROL D1210 D1225 D1240 D2410 D2425 D2450 D2475 D2490 OUTPUT SPECIFICATIONS À Operating Voltage (47-63 Hz) [Vrms] 24-140 24-140 24-140 24-280 24-280 24-280 24-280 24-280 Max. Load Current ´ [Arms] 10 25 40 10 25 50 75 90 Min. Load Current, [mArms] 40 40 40 40 40 40 40 40 Transient Overvoltage [Vpk] 400 400 400 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 120 250 625 120 250 625 1000 1200 Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 60 260 1620 60 260 1620 4150 6000 Max. Off-State Leakage Current @ Rated Voltage [mArms] 8 8 8 1 01 01 01 01 0 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]\ 500 500 500 500 500 500 500 500 Max. Turn-On Time ˆ 1/2 Cycle (DC Control), 10.0 msec (AC Control) Max. Turn-Off Time 1/2 Cycle (DC Control), 40.0 msec(AC Control) INPUT SPECIFICATIONS À DC CONTROL AC CONTROL AC CONTROL (E SUFFIX) Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms Max. Reverse Voltage -32 Vdc --- --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms Nominal Input Impedance 1500 Ohms 60K Ohms 9.0K Ohms Typical Input Current 3.4mA @ 5 Vdc, 20mA @ 28Vdc 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms GENERAL NOTES À All parameters at 25ºC unless otherwise specified. \ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ´ Heat sinking required, for derating curves see page 2. ˆ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).

  • Zero Voltage and Random Turn-On Switching
  • Panel Mount
  • 600V Blocking Capability
  • Internal Snubber
  • 110 & 125A Models Available FastFax Document No. 151 SERIES1.032698, PAGE 1 OF 3 Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turn- on (phase controllable) and normally closed (Form B) versions with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9002 Certified facility for optimum product performance and reliability. Series 1 10-90Amp • 120, 240 Vac • AC Output ©1998 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany

Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs 1.87 (47.5) .78 (19.8) 2.30 (58.4) 1.70 (43.2) .90 (22.9) .45 (11.4) 1.10 (27.9) 8-32 TERMINAL (2 PLACES ) 1.00 (25.4) 6-32 TERMINAL (2 PLACES) 1.80 (45.7) SOLID-STATE RELAY

12 OUTPUT

+-- INPUT MOUNTING HOLE/SLOT 0.17 (4.3) DIA. BASE PLATE .125 (3.2) .90 (22.9) FASTON TERMINAL .187 X .032 (2 PLCS.) BASE PLATE .125 (3.2) FASTON TERMINAL .250 X .032 (2 PLCS.) 1.87 (47.5) .78 (19.8) 2.30 (58.4) 1.70 (43.2) .87 REF. (22.2)

43 INPUT

1.00 (25.4) 1.80 (45.7) .45 (11.4) 1.10 (27.9)MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Series 1 10-90Amp • 120, 240 Vac • AC Output FastFax Document No.151 SERIES1.032698, PAGE 2 OF 3 AVAILABLE OPTIONS -B Normally Closed (Form B) Example: D2450-B, A2450-B 4D 400 Hz Operation 10-50 Amp Models Only Zero Cross Switching Only Example: 4D2450 E 24 Vac Input (18-36 Vac) Example: A2450E -10 Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: D2450-10 F Faston Terminals (Up to 50A Models) .250 x .032 Faston Terminals Example: D1225F GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms Insulation Resistance (Min.) @ 500 Vdc 109 Ohm Max. Capacitance Input/Output 8 pF Ambient Operating Temperature Range -40 to 80ºC Ambient Storage Temperature Range -40 to 125ºC MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished, Unmounted APPROVALS UL E116949 CSA LR81689 VDE 10143 UG (Not Applicable: -B and 4D) Crydom Heat Sinks offer excellent thermal management and are per - fectly matched to the load current rat- ings of Crydom panel mount relays. Request Crydom’s Heat Sink specifica- tion sheet for all the details. ©1998 CRYDOM CORP, Specifications subject to change without notice. All dimensions are in inches (millimeters) For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany

Load Current [Arms] Max Ambient Temp. [ºC] Power Dissipation 110 115 120 Base Plate Temp [ºC] 10A 9ºC/W 5ºC/W 3ºC/W7ºC/W NO HEATSINK 5 10 20 2515 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] Power Dissipation 120 Base Plate Temp [ºC] 25A 1ºC/W 100 110 3ºC/W NO HEATSINK 10 20 40 5030 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] Power Dissipation Base Plate Temp [ºC] 50A 2ºC/W 1ºC/W .5ºC/W 100 110 120 1.5ºC/W NO HEATSINK 120 15 30 60 7545 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] Power Dissipation 100 110 120 Base Plate Temp [ºC] 75A .5ºC/W 1ºC/W 120 20 40 80 060 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] Power Dissipation 100 110 120 Base Plate Temp [ºC] 90A 1ºC/W .4ºC/W .2ºC/W .5ºC/W 2ºC/W .3ºC/W Series 1 10-90Amp • 120, 240 Vac • AC Output CURRENT DERATING CURVES FastFax Document No.151 SERIES1.032698, PAGE 3 OF 3 ©1998 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany