DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
D1U3CS-D-1600-12-HC4EC Series 81mm Front End DC-DC Power Converter D1U3CS-D-1600-12-HC4EC.A02 Page 1 of 5 www.murata-ps.com/support www.murata-ps.com For full details go to www.murata-ps.com/rohs Ḥ
FEATURES
1600W output power (across the full DC input voltage range) 93% typical effi ciency at 50% FL 12VDC Main output 3.3VSB output (20W) 29W/in3 power density N+1 Redundancy Capable; hot plug/swap (up to 8 modules in parallel) Active current sharing on 12V main output; integral MOSFET ORING Over-Voltage, Over-Current; Over-Temperature Protection Internal variable speed cooling fans PMBus™ Power Management Bus RoHS Compliant Two-year warranty PRODUCT OVERVIEW The D1U3CS-D-1600-12-HC4EC is a highly effi cient 1600 watt, DC input front end module with a 12V main output and a choice of 3.3V (20W) standby and airfl ow direction. The power module is able to current share with up to eight (8) other power modules of the same type operating in parallel or N+1 redundancy. The supplies may be hot plugged, and include integral isolation devices. The power modules are fully protected from overload and overvoltage and are able to auto-recover from overtemperature faults. A Status LED is provided on the front panel and additional control and status reporting is provided by hardware logic signals and via a PMBus™ digital interface. A low profi le sub 1U height enclosure provides an excellent power density of 29W/in3 that is ideal for delivering reliable, effi cient power to servers; workstations; storage systems and other 12V distributed power systems. CB Test Certifi cate and Test Report www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html Available now at www.murata-ps.com/en/3d/acdc.html ORDERING GUIDE Model Number Power Output Main Output Standby Output Airfl ow D1U3CS-D-1600-12-HC4EC 1600W 12Vdc 3.3Vdc Back to Front INPUT CHARACTERISTICS Parameter Conditions Min Typ Max Units DC Input Voltage Operating Range -40 -48/-60 -72 VdcTurn-on Input Voltage Ramp Up -39.5 -40 -40.5 Turn-off Input Voltage Ramp Down -35.5 -36 -36.5 Maximum Current @ VIN = -48Vdc 1600W 40 Adc DC Input Inrush Peak Current Cold start between 0 to 200ms -40 50 Apk-72 100 Effi ciency (-48Vdc) 20% FL 92 %50% FL 93 100% FL 90 Reverse polarity protection Reversed input cables; no internal fuse failure +40 +72 Vdc OUTPUT VOLTAGE CHARATERISTICS Output Voltage Parameter Conditions Min Typ Max Units Main 12V Voltage Set Point Accuracy 12 Vdc Line & Load Regulation 11.4 12.6 Ripple & Noise 1 20MHz Bandwidth 120 mV PP Output Current -40Vdc to -72Vdc DC Input Voltage Range 0 133A A Load Capacitance 30,000 μF 3.3VSB Voltage Set Point 3.3 Vdc Line & Load Regulation 3.2 3.4 Ripple Voltage & Noise 1 20MHz Bandwidth 120 mV PP Output Current -40Vdc to -72Vdc 0 6 A Load Capacitance 10,000 μF 1 Ripple and noise are measurements are to be performed with a parallel combination of a 0.1μF ceramic capacitor and 10μF tantalum capacitance on each of the power module output measurement nodes. A short coaxial cable from measurement point to ’scope shall be used.
D1U3CS-D-1600-12-HC4EC Series 81mm Front End DC-DC Power Converter D1U3CS-D-1600-12-HC4EC.A02 Page 2 of 5 www.murata-ps.com/support OUTPUT CHARACTERISTICS Parameter Conditions Min Typ Max Units Remote Sense (Main Output) Overall compensation at full load; +VE & -VE connections 120 mV Output Rise (Monotonic) 10% to 95% rise time No positive voltage excursion Startup Time DC Ramp Up 1.5 2.5 s PS_ON activation 200 ms Transient Response 12V, 50%-100% or 100%-50% step load; 1A/μs slew rate ±600 mV3.3SB 50-100% or 100%-50% step load 1A/μs slew rate ±165 Current Sharing Accuracy At 100% load (between sharing modules; up to 8 in parallel) ±10 % Hot Swap Transients ±5 % Hold Up Time
2 FL (Full Load) 1 ms
2 Assumes deployment on systems with dual redundant “A” and “B” DC input feeds
ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min Typ Max Units Storage Temperature Range Non-Condensing -40 70 °COperating Temperature Range 1600W Output Power 0 50 Operating Humidity Non-Condensing 5 95 %Storage Humidity 59 0 Altitude (no derating at 40°C) 3000 mAltitude (no derating at 50°C) 1800 Shock Non-Operating 30 G Sinusoidal Vibration Operational, 0.5G; 5-500Hz MTBF Telcordia SR-332 M1C1 @ 40°C 395 K Hours Safety Approvals (Standards) CSA/CSA-C22.2 No.60950-1-07 2nd Ed, Amendment 1:2011 ANSI/UL Std. No. 60950-1-2011 IEC 60950-1:2005, (2nd Edition) + A1:2009 CE Marking per LVD DIRECTIVE 2006/95/EC Input Fusing Internal 60A/170Vdc fast blow fuse on the DC line input Switching Frequency 70KHz for the Boost Converter; 240KHz for the Main Output Converter Material Flammability UL94-V0 Weight 2.84/1.31 lbs/kg PROTECTION CHARACTERISTICS Output Parameter Conditions Min. Typ. Max. Units N/A Over-Temp Auto re-start 57 60 63 °C 12V (Main) Over-Voltage Latching; toggle PS_ON or recycle DC input to reset 13.3 14.5 V Over-Current For slow overload events a constant current will be sustained for 1sec followed by a latch off that will auto reset in 5secs. For hard (short circuit) events the output will shut down within 50ms and auto restart within 200ms. This cycle will be repeated ten times at which point the output will permanently latch off. The power module will require to be reset by recycling the incoming DC source or “toggling” PS_ON. 140 160 A 3.3VSB Over-Voltage Latching; toggle PS_ON or recycle DC input to reset 3.9 4.3 V Over-Current Shutdown followed by auto-recovery 6.5 9.0 A ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Isolation Input to Output - Basic 1000 Vdc Output to Chassis (Ground) 500 Vdc STATUS INDICATORS Conditions LED Status No incoming DC supply present; power module completely unpowered (off). LED not illuminated Standby Rail ON; Main Output OFF; DC input present & correct Blinking Green Standby Rail ON; Main Output ON Solid Green Main Output overcurrent; undervoltage, overvoltage warning Blinking Amber FAN_FAULT; overtemperature; standby rail overcurrent, Main Output overcurrent or overvoltage Solid Amber
D1U3CS-D-1600-12-HC4EC Series 81mm Front End DC-DC Power Converter D1U3CS-D-1600-12-HC4EC.A02 Page 3 of 5 www.murata-ps.com/support EMISSIONS AND IMMUNITY Characteristic Standard Compliance Conducted Emissions FCC 47 CFR Part 15; CSIPR 22/EN55022 Class B ESD Immunity IEC/EN 61000-4-2; Level 3; Criteria A Radiated Field Immunity IEC/EN 61000-4-3 Level 3; Criteria B Electrical Fast Transients/Burst Immunity IEC/EN 61000-4-4 Level 3; Criteria B Surge Immunity IEC/EN 61000-4-5 Level 3; Criteria A RF Conducted Immunity IEC/EN 61000-4-6 Level 3; Criteria A Magnetic Field Immunity IEC/EN 61000-4-8 3A/m; Criteria B Voltage Dips & Interruptions NEBS GR-1089-CORE Issue Relevant sections and compliance levels TBD OUTPUT CONNECTOR & SIGNAL INTERFACE DC Output and Signal Connector: FCI# 51731-057-LF NB: B4 is the shortest “last make, fi rst break” sequenced signal pin. Blade Assignment Function Description Current (Amps per Pin) PB1, PB2, PB3 +12V GND Main Output Voltage, Return 30 PB4, PB5, PB6 +12V OUT Main Output Voltage 30 Signal Pin Assignment Signal Name Description A1 PS_ON_L An input pulled up via an internal 10K ohm to the Standby rail. When pulled low (<0.7Vdc; via an open collector/drain drive or connection to GND) the Main Output will be turned on/enabled) N/A A2 +12VRS_RETURN Main Output Remote Sense (-VE/Return) N/A A3 TEMP_OK TTL compatible Logic HIGH provided when the temperature is within the allowable range of operation. A4 PS_SEATED (PS_ PRESENT) Internally connected to GND within the power module; when correctly seated the corresponding mating connector pin is grounded and therefore allows detection that the power module is in situ. N/A A5, B5, C5, D5 +VSB Standby Voltage Output 2.0 A6, B6, C6, D6 +VSB GND Standby Voltage Output, Return/GND 2.0 B1 DC_OK A TTL Logic HIGH (>2.1Vdc) is provided to indicate the DC Input is present (“OK”) and within operational limits. N/A B2 +12VRS Main 12V output remote sense line. N/A B3 +12V_ISHARE Main 12V output current share bus (see Current Sharing Notes). N/A B4 PS_INHIBIT/PS_KILL This is the shortest “last make, fi rst break” (last to mate in the sequence). If left open circuit then the Main & Standby outputs will be inhibited (no output). When inserted in to the system slot this pin must be pulled “low” by the system to enable (turn on) the Main output and only after all other pins are connected and the power module is correctly seated. N/A C1 SDA I 2C Serial Data Line N/A C2 SCL I 2C Serial Clock Line N/A C3 PWR_GD Power Good signal. An active TTL HIGH signifi es when the output is within regulation limits. N/A C4 FAN_FAIL Fan Fail signal (failure or locked rotor) N/A D1 A0 I 2C LSB (Least Signifi cant Bit) Address Line N/A D2 A1 I 2C MSB (Most Signifi cant Bit) Address Line N/A D3 S_INT System Interrupt; call for system attention to check power module status N/A D4 N/C No User Connection N/A MATING CONNECTOR Supplier Press Fit, Straight Press Fit, Right Angle Solder Straight Solder Right Angle DC INPUT TERMINAL BLOCK Dinkle Enterprise 2 Way Terminal Block; 40A rating; +VE & -VE DC Input cable connections DT-7C-B14W D1 D2 D3 D4 D5 D6 PB1 PB2 PB3 PB4 PB5 PB6 C1 C2 C3 C4 C5 C6 B1 B2 B3 B4 B5 B6 A1 A2 A3 A4 A5 A6
D1U3CS-D-1600-12-HC4EC Series 81mm Front End DC-DC Power Converter D1U3CS-D-1600-12-HC4EC.A02 Page 4 of 5 www.murata-ps.com/support WIRING DIAGRAM FOR OUTPUT CURRENT SHARING NOTES 1. Main 12VDC Output: Analogue active share bus. The ISHARE bus (Pin B3) must be connected on all sharing modules. It is not required that the SENSE signals are connected to the remote load for current share to operate correctly. 2. Up to eight (8) power modules can be connected in parallel (non-redundant) or N+1 confi guration. The current share bus is analogue bi-directional (can source or sink voltage representation of the current on the ISHARE bus. The voltage of the bus would measure 8VDC for a single power module at 100% load; for two (2) modules sharing a common load the ISHARE bus voltage would be 4V for a perfect 50/50 current share scenario. 3. The VSTANDBY output of power modules can also be connected in parallel and have internal output isolation devices; however t he combined available power is limited to that available from a single power module (3.3V; 20W) irrespective of the number of modules connected in parallel. +12V GND +12VRS (Main Output Remote Sense) +12VRS_RETURN +12V OUTB2 PB4-6 PB1-3 Dotted lines show optional remote sense connections. Optional remote sense lines can be attached to a load that is a distance away from the power supply to improve regulation at the load. D1U3CS 12V load A6,B6,C6,D6 A5,B5,C5,D5 FET, BJT, wire or switch (debounced ) to turn on +12V main output +VSB load +VSB PS_ON_L +VSB GND B4 PS_INHIBIT/PS_KILL D1U3CS B3 +12V_ISHARE PS_INHIBIT/PS_KILL B4 A6,B6,C6,D6+VSB GND PS_ON_L A1 A5,B5,C5,D5+VSB A2+12VRS_RETURN +12V_ISHARE +12V GND +12V OUT +12VRS (Main Output Remote Sense) B2PB4-6 PB1-3
D1U3CS-D-1600-12-HC4EC Series 81mm Front End DC-DC Power Converter D1U3CS-D-1600-12-HC4EC.A02 Page 5 of 5 www.murata-ps.com/support Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. © 2015 Murata Power Solutions, Inc. Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ MECHANICAL DIMENSIONS Notes 2. Safety earth/ground connection via separate dedicated M4 pan head screw connection (located above terminal block) OPTIONAL ACCESSORIES Description Part Number D1U3CS-12 Output Interface Connector Card D1U3CS-12-CONC APPLICATION NOTES Document Number Description Link ACAN-41 D1U3CS-12-CONC Output Interface Connector Card www.murata-ps.com/data/apnotes/acan-41.pdf ACAN-57 D1U3CS-12 Communications Protocol Direction of Airfl ow