Features
- High speed switching
- High Collector Voltage : VCBO = 700V
- Suitable for Switching Regulator and Motor Control
Ordering Information
Type NO. Marking Package Code STD13007 STD13007 TO-220AB A b s o l u t e m a x i m u m r a t i n g s (Ta=25°C) Characteristic Symbol Rating Unit Collector-Base voltage V CBO 700 V Collector-Emitter voltage V CEO 400 V Emitter-base voltage V EBO 9 V Collector current (DC) I C 8 A Collector current (Pulse) I CM 16 A Base current (DC) I B 4 A Collector Power dissipation (Tc=25℃) PC 80 W Junction temperature T j 150 °C Storage temperature T stg -55~150 °C Characteristic Symbol Typ. Max Unit Junction-case R th(J-C) - 1.56 Thermal resistance Junction-ambient R th(J-a) - 83.3 ℃/W C E B
E l e c t r i c a l C h a r a c t e r i s t i c s (Ta=25°C) Characteristic Symbol Test Condition Min. Typ. Max. Unit Collector-Emitter sustaining voltage BV CEO(sus) IC=10mA, IB=0 400 - - V Emitter cut-off current I EBO V EB=9V, IC=0 - - 1 mA IC=2A, VCE=5V※ 10 - 45 DC Current gain h FE* IC=5A, VCE=5V 5 - 30 IC=2A, IB=0.4A - - 1 IC=5A, IB=1A - - 2 Collector-Emitter saturation voltage VCE(sat)* IC=8A, IB=2A - - 3 V IC=2A, IB=0.4A - - 1.2 Base-Emitter saturation voltage V BE(sat)* IC=5A, IB=1A - - 1.6 V Transition frequency f T V CE=10V, IC=0.5A, f=1MHz - 14 - MHz Output capacitance C ob V CB=10V, IE=0, f=0.1MHz - 80 - ㎊ Turn on Time t on - 1.6 - Storage Time t stg - 3 - Fall Time t f VCC=125V, IC=5A IB1=-IB2=1A - 0.7 - * Pulse test: PW≤300 ㎲, Duty cycle≤2%. ※hFE rank / A : 10~30, B : 25~45
Electrical Characteristic Curves Fig. 1 P C - TC Fig. 2 V BE(sat) , VCE(sat) - IC Fig. 3 h FE-IC Fig. 4 t f , tstg - IC Fig. 5 td , tr - IC Fig. 6 Cob - V CB
Electrical Characteristic Curves Fig. 7 Safe Operating Area
The AUK Corp. products are intended for the use as components in general electronic equipment (Office and co mmunication equipment, m easuring equipment, home appliance, etc.). Please make sure that you consult with us before you use these AUK Corp. products in equipments which require high quality and / or reliability, and in equipments which could have major impact to th e welfare of human life(atomi c energy control, airplane, spaceship, transportation, co mbustion control, all types of safety device, etc.). AUK Corp. cannot accept liability to any damage which may occur in case these AUK Corp. products were used in the mentioned equi pments without prior consultation with AUK Corp.. Specifications mentioned in this publication are subject to change without notice.