D030505M-1W MORNSUN | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
The copyright and authority for the interpretation of the products are reserved by Mornsun Specifications subject to change without notice. D_M-1W A/0-2009 Page 1 of 2 D_M-1W Series 1W,FIXED INPUT,1000V ISOLATED & UNREGULATED TWIN OUTPUT DC-DC CONVERTER multi-country patent protection RoHS PRODUCT PROGRAM Input Output Voltage (VDC) Current (mA) Part Number Nominal Range Voltage (VDC) Max. Min. Efficiency (%, Typ) D030505M-1W 3.3 2.97-3.63 5 100 10 70 D050303M-1W 3.3 100 10 62 D050505M-1W 5 4.5-5.5 5 100 10 71 COMMON SPECIFICATIONS Item Test Conditions Min. Typ. Max. Units Storage humidity range 95 % Operating temperature -40 85 Storage temperature -55 125 Lead temperature 1.5mm from case for 10 seconds 300 Temp. rise at full load 15 25 Short circuit protection* 1 S Cooling Free air convection Case material Plastic(UL94-V0) MTBF 1.4 g Weight 3500 K hours *Supply voltage must be discontinued at the end of short circuit duration. ISOLATION SPECIFICATIONS Item Test Conditions Min. Typ. Max. Units Isolation voltage (Vin/Vout) Tested for 1 minute and 1mA max 1000 Isolation voltage (Vo1/Vo2) Tested for 1 minute and 1mA max 1000 VDC Isolation resistance (Vin/Vout) Test at 500VDC 1000 Isolation resistance (Vo1/Vo2) Test at 500VDC 1000 MΩ Isolation capacitance(Vin/Vout) 30 Isolation capacitance(Vo1/Vo2) 30 pF
FEATURES
- Small footprint
- SIP package
- Temperature range: -40°C~+85°C
- 1KVDC isolation
- No Heat sink required
- No external component required
- Internal SMD Construction
- Industry standard pinout
- RoHS Compliance
APPLICATIONS
The D_M-1W Series are specially designed for applications where a group of polar power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is fixed (voltage variation ≤ ±10%); 2) Where isolation is necessary between input and output (isolation voltage ≤1000VDC); 3) Where the regulation of the output voltage and the output ripple noise are not demanding. Such as: purely digital circuits, ordinary low frequency analog circuits, and IGBT power device driving circuits. MODEL SELECTION D050505M-1W Rated Power Product Series The 2nd Output Voltage The 1st Output Voltage Input Voltage Package Style MORNSUN Science& Technology co.,Ltd. Address: 2th floor 6th building, Hangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax: 86-20-38601272 http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by Mornsun Specifications subject to change without notice. D_M-1W A/0-2009 Page 2 of 2 OUTPUT SPECIFICATIONS TYPICAL CHARACTERISTICS Item Test Conditions Min. Typ. Max. Units Output power 0.1 1 W Line regulation For Vin change of 1% ±1.5 10% to 100% load (3.3V output) 15 20 Load regulation 10% to 100% load(5V output) 12.8 15 Output voltage accuracy See tolerance envelope graph Temperature drift 100% full load ±0.03 %/℃ Ripple & Noise* 20MHz Bandwidth 75 100 mVp-p Switching frequency Full load, nominal input 130 KHz *Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power Converter section, application notes. Operating Temp.(C) o APPLICATION NOTE RECOMMENDED CIRCUIT Requirement on output load To ensure this module can operate efficiently and reliably, During operation, the minimum output load is not less than 10% of the full load, and that this product should never be operated under no load! If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load, or use our company’s products with a lower rated output power. Recommended circuit If y ou want to further decrease the input/output ripple, an “LC” filtering network may be connected to the input and output ends of the DC/DC converter, see (Figure 1). It should also be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid mutual interference . However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the saf e and reliable operation is ensured, the recommended capacitance of its filter capacitor sees (Table 1). Output Voltage Regulation and Over-voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over-current protec tion is a linear voltage regulator with overheat protection that is connected to the input or output end in series (Figure 2). Overload Protection Under normal oper ating conditions, the output circuit of these products has no protection against overload. The simplest method is to connect a self- recovery fuse in series at the input end or add a circuit breaker to the circuit. No parallel connection or plug and play Vin GND +Vo1 0V1 DCC L DC C +Vo2 0V2 L C L (Figure 1) Vin GND REG Vin GND REG +Vo1 0V1 +Vo1 0V1 DCDC DCDC +Vo2 0V2 REG +Vo2 0V2 (Figure 2) EXTERNAL CAPACITOR TABLE (TABLE 1) Vin(VDC) Cin(uF) Cout(uF) Vout(VDC) It’s not recommended to connect any external capacitor in the applic ation field with less than 0.5 watt output.
The copyright and authority for the interpretation of the products are reserved by Mornsun Specifications subject to change without notice. D_M-1W A/0-2009 Page 3 of 3 OUTLINE DIMENSIONS & PIN CONNECTIONS Vin GND 0V1 Vo1 ∅∅1.00 [0.039] 16.50 [0.650] 1246 53 12.70 [0.500] 6.00 [0.236] 0.30 [0.012] 7.50 [0.295] 4.10 [0.161] 0.50 [0.020] 0.50 [0.020] 12.70 [0.500] 0.90 [0.035] 2.54 [0.100] 2.54 [0.100] 1246 53 9.40 [0.370] 16.70 [0.657] 12.20 [0.480] 0.60 [0.024] 4.70 [0.185] 0V2 Vo2 Pin FOOTPRINT DETAILS Note: Unit:mm[inch] Pin section tolerances:0.10mm[0.004inch] General tolerances:0.25mm[0.010inch] MECHANICAL DIMENSIONSRECOMMENDED FOOTPRINT TUBE OUTLINE DIMENSIONS Note: Unit :mm[inch] General tolerances: ±0.50mm[±0.020inch] L=530mm[20.866inch] Tube Quantity: 30pcs L=220mm[8.661inch] Tube Quantity: 11pcs (Side View) (Bottom View) Function Note: 1. Operation under minimum load will not damage the converter; However, they may not meet all specification listed. 2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 3. In this datasheet, all the test methods of indications are based on corporate standards. 4. Only typical models listed, other models may be different, please contact our technical person for more details.