CXA-L0605C-VJL TDK | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
CUSTOMER'S PRODUCT NAME: DC/AC INVERTER UNIT CXA- L0605C-VxL TDK PRODUCT NAME: MESSRS : DWG.No. PREPARED BY APPROVED BY AUTHORIZED BY K.Yamaishi H.Masuoka CTR-3818-X K.Negoro Product Drawing TDK-Lambda Corporation *Notice Product Drawing is not contract. This is only technical data. This technical data may change internal description without any notice. When you design final product please request us specification through our sales or distributors. After you receive the specification, the contract is effective on signature of the specification. TENTATIVE
No. MATERIALS NAME MATERIAL REMARK PRODUCT NAME or MODEL,TITLE DC-AC INVERTER UNIT CXA-L0605C-VxL PAGE NAME OF DRAWING DRAWING No. Product Drawing CTR-3818-X TSB-08-01-05(00) form-6(A4) TDK-L TDK-L TDK-L TDK-Lambda ambda ambda ambda QU <The specifications may be changed without any notice.> TE NTATIVE When using this product, give due consideration to the precautionary notes described below and ensure a safe design. Inappropriate use may result in electric shock, injury or fire. Caution Precautionary Notes Regarding the Use of This Inverter /circle4This product is designed for lighting Cold Cathode Fluorescent Lamps. Do not use it with any other load. /circle4Store this product under the conditions defined in the specification document. /circle4Do not store this product in an environment where dust, dirt or corrosive gas(salt,acid,base, etc.) is present. /circle4This product is subject to high voltage. If there is a possibility that the user may touch the product, provide a proper warning indication in order to draw the user's attention. /circle4This product is designed for use with general electronic equipment. If it is to be used with medical equipment that directly affects human life or for the control of transportation equipment to which passengers entrust their lives, provide thorough fail-safe measures. /circle4Consult us before using if this product is to be installed in a habitual vibration environment (vehicle, etc.). /circle4Avoid using this product under high temperatures or high humidity or in an environment in which dust, dirt or any corrosive gas (salt,acid,base, etc.) is present. Also,be careful not to allow the formation of dew condensation. It may result in damage or electric shock. /circle4If the product does not have a built-in protective circuit (circuit breaker, fuse, etc.), it is recommended that a fuse be used at the input stage to prevent the generation of smoke or fire in the event of a malfunction. Even when the product has a built-in protective circuit (circuit breaker, fuse, etc.), the circuit may not function properly due to inappropriate operating conditions or power-supply capacity. It is recommended that an appropriate protective circuit (circuit breaker, fuse, etc.) be provided separately from the built-in circuit. /circle4Use the product only within the specified input voltage, output power, output voltage and operating temperature ranges. Exceeding these values may result in damage, etc. /circle4Provide a measure for the prevention of surge voltage due to lightning, etc. Abnormal voltage may result in damage, etc. /circle4To prevent problems from occurring as a result of a short circuit in the high voltage section, be sure to take appropriate measures to prevent the entry of foreign substances into the inverter after it is installed. /circle4This product is not designed to provide resistance to radiation. /circle4In order to protect the inverter from vibration and shock, be sure to use all the mounting holes when installing the inverter. /circle4Ripples could be superimposed on the voltage and the current in the input source connected to the inverter , depending on the impedance in the input source, wiring, etc. When you select an input source, please check waveforms, etc on the final set. /circle4Please use all the mounting holes, because to defend the converter from vibration and impact. Warning /circle4This product is subject to high voltage. Do not touch it while the power is on. Failing to do so may result in electric shock. Handling Precautions /circle4This product uses thin wires. Observe the following precautions and handle it with care so as not to cause wire breakage. Broken wire may result in damage, etc. /xrhombusDo not stack multiple products on top of one another. /xrhombusDo not allow the product to come in contact with tools, etc. /circle4Do not apply excessive stress during installation. It may cause chipping and cracking,resulting in damage, etc. /circle4Provide clearance between the high-voltage section of this product and the frame body on which the product is installed and also the conductor section as on page 2 , [1] ”Outline” . /circle4Do not use the product after it has been dropped because there is the possibility that components have been damaged.
No. MATERIALS NAME MATERIAL REMARK PRODUCT NAME or MODEL,TITLE DC-AC INVERTER UNIT CXA-L0605C-VxL PAGE NAME OF DRAWING DRAWING No. Product Drawing CTR-3818-X TSB-08-01-05(00) form-6(A4) TDK-L TDK-L TDK-L TDK-Lambda ambda ambda ambda QU <The specifications may be changed without any notice.> TE NTATIVE 2. Contents 1. Part Name The part name is CXA-L0605C-VxL 1.Appearance,Structure and Dimensions Outline Pin configration 2.Characteristics 3.Electrical Characteristics 4.Test circuit Absolute Maximum Ratings Item Page Attched view refer to [2] refer to [1] refer to [4] refer to [3] refer to [1] refer to [7] 5.Reliability Test refer to [5] 7.Others Test Cond Std Warranty Others 6.Packing and Marking refer to [6] 8
No. MATERIALS NAME MATERIAL REMARK PRODUCT NAME or MODEL,TITLE DC-AC INVERTER UNIT CXA-L0605C-VxL PAGE NAME OF DRAWING DRAWING No. Product Drawing CTR-3818-X TSB-08-01-05(00) form-6(A4) TDK-L TDK-L TDK-L TDK-Lambda ambda ambda ambda QU <The specifications may be changed without any notice.> TE NTATIVE Unit : mm Weight : 13.7g typ.
- Features ● ・This inverter is one lamp. It has Dimming function(Analog Dimming System) and Remote function. ・The high-voltage area (terminals and patterns) is coated with silicone so as to avoid the defects caused by dust. ・This product is conformity to RoHS directive. (※) (※)Conformity to RoHS Directive:This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used,except for exempted applications. [1] Outline 1-1. Outline ※Please secure 3mm or longer space distance from the high voltage generating area in all directions. Please see Note 1-3 for the details. The dimensional deviation not instructed is assumed to be ±0.5mm 95.5max. ② ① ③ 82±0.2 (4) (4.5) 12.8± 0.2 CN1 20max. 2-φ2.2±0.2 CN2 CXA-L0605C-VJL 0703 MADE IN JAPAN Silicone SM02(8.0)B-BHS-1-TB (JST) SM02B-BHSS-1-TB (JST) a:45mm part generating high voltage (all the 45mm part from the edge of the board)※ 8max. (1) Tape No. Qu ① 1 ② 1 Remark UL94V-0 t=1.0 Molex JST JST Mates With 51021-0500 BHR-03VS-1 BHSR-02VS-1 Part Description PCB Input Connector CN1 Output Connector CN2 Material Composite (CEM-3) 53261-0571 SM02(8.0)B-BHS-1-TB(LF)(SN) SM02B-BHSS-1-TB(LF)(SN) Output Current:6mArms typ Input Voltage:5V typ *Part Name example C X A - L 0 6 0 5 C - V□ L Output Connector---J:SM02(8.0)B-BHS-1-TB(LF)(SN) S:SM02B-BHSS-1-TB(LF)(SN) Dimming System:Analog Dimming Changing of CXA-L0605-VxL Inverter Output Power:4~5W The position of High Voltage Output terminal : L-Left side
No. MATERIALS NAME MATERIAL REMARK PRODUCT NAME or MODEL,TITLE DC-AC INVERTER UNIT CXA-L0605C-VxL PAGE NAME OF DRAWING DRAWING No. Product Drawing CTR-3818-X TSB-08-01-05(00) form-6(A4) TDK-L TDK-L TDK-L TDK-Lambda ambda ambda ambda QU <The specifications may be changed without any notice.> TE NTATIVE 1-2. Connector Configuration Input side For circuit connection, please prefer to test circuit diagram [4]. Please use minimum of 3mm clearance (all directions) between inverter high voltage area and any conductors. Please refer to mechanical drawing for marking of high voltage area. Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the reading at the output connector would be less than the actual value. If the start up voltage falls below Cold Cathode Tube strike voltage, the C CFL will not light up easily specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal operation due to coupling/leakage capacitance of inverter high volt age area to any surrounding conductor. Note1-2. Note1-1. Marking of TDK part No, Date code, Country of origin. 1) TDK part No., Date code, Country of origin, TDK-Lambda Logo, is marked on the transformer. 2) Date code example. (ex. Jul. 3. 2010) 3) Country of origin code example. (ex. MADE IN JAPAN.MADE IN MALAYSIA). Fig1.High Voltage Code Note1-3. Note1-4. Note1-5. LCD MODULE Pin No. CN1-1 CN1-2 CN1-3 CN1-4 CN1-5 Symbols Vin GND Vrmt Vbr N.C. Ratings 4.75~5.25V 0V / 2.5V-Vin 0~3V Notes 0-0.4V : OFF 2.5-Vin : ON Control N.C. CN2-1 CN2-2 VHIGH N.C. 600Vrms 6mArms CN2-3 VLOW (2V) Pin No. Symbols Ratings CN2-1 CN2-2 VHIGH 600Vrms 6mArms Output side CN2 (CXA-L0605-VSL) VLOW (2V) Pin No. Symbols Ratings Output side CN2 (CXA-L0605-VJL) 0 7 0 3 Two digits of production day. Last digit of production year. CN2 OK NG CN2 LCD MODULE
No. MATERIALS NAME MATERIAL REMARK PRODUCT NAME or MODEL,TITLE DC-AC INVERTER UNIT CXA-L0605C-VxL PAGE NAME OF DRAWING DRAWING No. Product Drawing CTR-3818-X TSB-08-01-05(00) form-6(A4) TDK-L TDK-L TDK-L TDK-Lambda ambda ambda ambda QU <The specifications may be changed without any notice.> TE NTATIVE [2] Absolute maximum ratings [3]Electrical specifications Please check your lamp characteristic for minimum operational current and set the limit point in your design to avoid flickering and/or abnormal operation. For proper operation of circuit protection (fuse or IC PROTECTOR),Please use mi nimum of 3.0A capacity for input power supply. Impedence from the wire connection can cause a ripple in the input. The product has an internal fuse of 1.5A. Please check that input current peak wave form does not exceed 1.5A. Note1-6. Note1-7. Note1-8. Item Output Current (Dimmingmax.) Symbol lout1 Conditions Specifications MIN. MAX. TYP. 5.4 5.3 6.6 6.7 Unit mArms Output Current (Dimmingmin.) lout3 2.4 3 3.6 0.8 - 1.0 Open Circuit Voltage Vopen Input Current Iin Frequency F kVrms 35 45 55 A 1.5 1.6 - kHz Vbr [V] Ta [℃] RL [kΩ] 23±5 -20~70 0-20~70 0~3 -20~70 -20~70 Vin [V] 4.75~5.25 4.75~5.25 4.75~5.25 4.75~5.25 4.75~5.25 lout2 23±5 Items Symbols Specification Unit Notes Input Voltage Load Resistance Operating Temp. range Storage Temp. range Humidity range Vin RL Ta Ts RH 0~5.25 110max. -20~70 -30~85 V kΩ %RH A maximum wet ball temperature is 38℃ No dew.
No. MATERIALS NAME MATERIAL REMARK PRODUCT NAME or MODEL,TITLE DC-AC INVERTER UNIT CXA-L0605C-VxL PAGE NAME OF DRAWING DRAWING No. Product Drawing CTR-3818-X TSB-08-01-05(00) form-6(A4) TDK-L TDK-L TDK-L TDK-Lambda ambda ambda ambda QU <The specifications may be changed without any notice.> TE NTATIVE [4] Test circuit Note.4-1.SW1(ON/OFF) Operation is as following; SW1 a b Operation Non operation Non operation Open Operation of unit V Note4-2.Safety Function 1000:1 F A Digital Multiple Meter(ADVA NTEST R6451A or equivalent) DC Current Meter(ADVANTEST R6451A or equivalent) True RMS Meter(KEITHLEY 2001 or equivalent.) High Frequency Current Mete r(KEITHLEY 2001 or equivalent) High Voltage Probe (Tektronix P3000 or equivalent) Frequency Countor(ADVANTE ST R6452A or equivalent) 1000:1 CN1-1 (Vin) V~F CN1-2 (GND) CN1-3 (Vrmt) CN1-4 (Vbr) CN1-5 (NC) Vbr=0V:Dimmingmax. T1-1 T1-6 LCD module Connected chart (reference) DC-AC inverter VLOW VHIGH A LCD module Lamp NC lin SW1 b a Vrmt 5V Vin 4.75 ~5.25V Vbr 0~3V RL CN2-1 (VHIGH ) CN2-3 (VLOW) CXA-L0605-VJL SM02(8.0)B-BHS-1-TB (JST) Iout CXA-L0605-VSL SM02B-BHSS-1-TB (JST) CN2-1 (VHIGH ) CN2-2 (VLOW) Vrmt terminal circuit (Reference) 47.1kΩ 22kΩ CN1-3 Vrmt 10kΩ 10kΩ IC1 CN1-1 Vin F Vopen Connect the High Frequency Current Meter to the Low-Voltage (VLOW) si de.
No. MATERIALS NAME MATERIAL REMARK PRODUCT NAME or MODEL,TITLE DC-AC INVERTER UNIT CXA-L0605C-VxL PAGE NAME OF DRAWING DRAWING No. Product Drawing CTR-3818-X TSB-08-01-05(00) form-6(A4) TDK-L TDK-L TDK-L TDK-Lambda ambda ambda ambda QU <The specifications may be changed without any notice.> TE NTATIVE [5] Reliability test Following test items are assured. Items Conditions -30°C 500h -30°C 500h Load cond.:TYP 85°C 500h 80°C 500h Load cond.:TYP Heat shock Vibration Shock -30°C to 80°C 30min.Each 100 Cycles 10~57Hz Amplitude 0.75mm or 9.8m/s2 58~500Hz 9.8m/s 2 Sweep:11min 60min each axis X,Y,Z 980m/s 2 11ms Harf-sine pulse 1 time each axis ±X,Y,Z Judgement Low Temp. Non operational Low Temp.operational High Temp. Non operational High Temp.operational Electrical and apperrance should be in the spec. Humidity (Non operational) 60°C 90~95%RH 500h
No. MATERIALS NAME MATERIAL REMARK PRODUCT NAME or MODEL,TITLE DC-AC INVERTER UNIT CXA-L0605C-VxL PAGE NAME OF DRAWING DRAWING No. Product Drawing CTR-3818-X TSB-08-01-05(00) form-6(A4) TDK-L TDK-L TDK-L TDK-Lambda ambda ambda ambda QU <The specifications may be changed without any notice.> TE NTATIVE 7-1.Test conditions Unless otherwise specified, the temperature to be (25 ±15) ℃ and humidity to be (65 ±20) %RH. 7-2. Warranty Warranty shall be for one year after delivery, and those products causing failure during the warranty period and which failures are attributed to the manufa cturer's responsibility shall be replaced at no charge. 7-3.Oters When any doubt arises about th is specification, it shall be discussed and decided upon between both parties. Shipment inspection result sheet are subject to change without notice. [7] Others [6] Packing and Marking A shipping box is packaged to avoid from water or damage. Following items are printed on the box. 6-1. 6-2. 6-3. TDK part No. Manufacture QTY. CXA-L0605C-VxL Tray (25pcs)×8stack= 200pcs/box (Cardboard) Outer carton (400mm:L)×(333mm:W)×(149mm:H) Marking TDK Part No. Manufacture QTY.