CXLdp Differential Pressure Transducer All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Duragauge®, Si-Glas™ and Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks CXLdp Pressure Transducer

FEATURES

TruAccuracy™- Terminal Point Accuracy method includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors. Rugged ABS package capable of DIN rail or panel mounting LED power status indicator Detachable Euro style terminal block Pressure ranges available down to ±0.05 in. H2O differential Unidirectional and Bidirectional ranges TYPICAL USES Fume Hood Control Building/Comfort Control System Building Energy Management Systems HVAC/R Critical Environments Fan Monitoring Duct Flow Clean Room Filter Monitoring KEY BENEFITS

  • Broad temperature capability
  • High performance ASIC based electronics
  • Superior long-term stability and repeatability
  • 3 year warranty PERFORMANCE SPECIFICATIONS Reference Temperature: 70 °F ±2 °F (21 °C ±1 °C) Accuracy: ±0.25%, ±0.4%, ±0.8% of span (Terminal Point Method: includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors) Stability: ≤±0.25% of span/year at reference conditions Media Compatibility: Clean, dry and non-corrosive gas NOT FOR USE WITH LIQUIDS Standard Response Time: 250 ms ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: Operating: Compensated: -40 °F to 180 °F (-40 °C to 82 °C) 0 °F to 160 °F (-17 °C to 71 °C) 35 °F to 130 °F (1.6 °C to 54 °C) Thermal Coefficients: Zero: ±0.03% of span/°F Span: ±0.03% of span/°F (From 70 °F reference temperature) Humidity Effects: No performance effect at 10-95% R.H. noncondensing CE Marked: Per DoC EMC Directive 2014/30/EU IEC/EN 61326-1:Edition 1.0 Industrial IEC/EN 61326-2-3:Edition 1.0 Annex BB Industrial RoHS: 2011/65/EU FUNCTIONAL SPECIFICATIONS Max. Static (Line) Pressure: 25 psi Burst: 25 psid Mounting Position Effect: ±1% of span/g (Calibration in vertical position is STD.) ELECTRICAL SPECIFICATIONS Circuit Protection: Reverse polarity and miswire protected Potentiometers: Zero & Span: ±5% of span (externally accessible) Voltage Output: 4-20 mA (2 wire) 0-5 Vdc (3 wire) 0-10 Vdc (3 wire) Supply Voltage: Supply Current: 12-36 Vdc 21.5 mA 11.5-36 Vdc or 24 Vac (±20%) 4.5 mA 14-36 Vdc or 24 Vac (±20%) 6 mA Proof: 15 psid

CXLdp Differential Pressure Transducer All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Duragauge®, Si-Glas™ and Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks LOAD LIMITATIONS 4-20 mA OUTPUT ONLY WETTED MATERIAL Media Clean, dry air/gases compatible with Aluminum, Titanium, PBT, Buna, Glass, Gold, Silicone Rubber, Silicon, Silicone RTV and Brass NOT FOR USE WITH LIQUIDS NON-WETTED Housing Fire-retardant ABS (Meets UL 94-5VA) LOOP SUPPLY VOLTAGE (Vdc) Vmin = 12V+ [0.022A*(RL)] *includes a 10% safety factor RL = RS + RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wire Resistance (ohms) OPERATING REGION LOOP SUPPLY VOLTAGE (VDC) 0 10 12 20 30 36 40 1250 1045 1000 750 500 250 LOOP RESISTANCE (/uni03A9) PHYSICAL SPECIFICATIONS Pressure Connections: 1/4 brass barbed fittings (male) 1/8 NPT Female brass Electrical Connection: Euro style pluggable terminal block accepts 12-26 gauge wire Visual Indicator: LED Weight: Approx. 2.5 oz Mounting: Threaded fastener and 35 mm DIN rail mount Enclosure Rating: NEMA 1, Fire-retardant ABS (meets UL94-5VA) Ashcroft’s TruAccuracy™ specification is exclusively based on terminal point methodology instead of statistically derived schemes like ‘best fit straight line’. TruAccuracy™ means the Ashcroft CXLdp has ±0.25% of span accuracy out of the box. Zero and span setting errors are already included in the ±0.25% of span accuracy spec. The CXLdp is ready to be installed with no additional calibration adjustments required. A unit from another manufacturer advertised as ±0.25% best fit straight line may actually be a ±1.25% to ±2.25% device. Using best fit straight line method, the accuracy spec does not include zero and span setting errors, which can be as much as ±1.00% each. What Does It Mean? Featuring a highly reliable variable capacitance sensor using the patented Ashcroft® Si-Glas™ sensor. This ultra-thin single crystal diaphragm provides inherent sensor repeatability and stability.SENSOR CROSS SECTION Ashcroft® Si-Glas™ Sensor Technology Sensor Cross Section The silicon diaphragm sensor has no glues or other organics to contribute to drift or mechanical degradation over time.

CXLdp Differential Pressure Transducer All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Duragauge®, Si-Glas™ and Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks ORDERING CODE Example: CX4 MB2 42 P25IW –XRH Model CX3 - CXLdp Series, ±0.25% of span, ± 0.03% of span T.C. /°F CX4 - CXLdp Series, ±0.40% of span, ± 0.03% of span T.C. /°F CX4 CX8 - CXLdp Series, ±0.80% of span, ± 0.03% of span T.C. /°F Pressure Connection F01 - 1/8 NPT Female MB1 - Board level only, no housing (consult factory) MB2 - 1/4 Barbed Male MB2 Output Signal 10 - 0-10 Vdc (includes user selectable 0-5 Vdc output) 42 - 4-20 mA 42 Pressure Range Differential Unidirectional Ranges P1IW - 0.1 in. H2O P2IW - 0.20 in. H 2O P25IW - 0.25 in. H2O P25IW P4IW - 0.40 in. H2O P5IW - 0.50 in. H2O P6IW - 0.60 in. H 2O P75IW - 0.75 in. H2O 1IW - 1.00 in. H2O 2IW - 2.00 in. H2O 2P5IW - 2.50 in. H2O 3IW - 3.00 in. H 2O 5IW - 5.00 in. H2O 10IW - 10.00 in. H2O 15IW - 15.00 in. H2O 20IW - 20.00 in. H 2O 25IW - 25.00 in. H2O 50IW - 50.00 in. H 2O 100IW - 100.00 in. H 2O Bi-directional Ranges P05IWL - ±0.05 in. H 2O P1IWL - ±0.10 in. H2O P25IWL - ±0.25 in. H 2O P5IWL - ±0.50 in. H 2O 1IWL - ±1.00 in. H2O 2IWL - ±2.00 in. H 2O 2P5IWL - ±2.50 in. H 2O 3IWL - ±3.00 in. H 2O 5IWL - ±5.00 in. H 2O 8IWL - ±8.00 in. H 2O 10IWL - ±10.00 in. H2O 15IWL - ±15.00 in. H2O 25IWL - ±25.00 in. H 2O 50IWL - ±50.00 in. H 2O Option (if including an option(s) must include an “X’’) –X__ 3P - 3 Point calibration data (for CX4 and CX8 only) AH - Plenum/conduit kit packaged with CXLdp NH - Stainless steel tag NN - Paper tag RH - 9 pt. Traceable calibration certificate (OPT. for CX4 and CX8 only, standard for CX3) RH

CXLdp Differential Pressure Transducer All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Duragauge®, Si-Glas™ and Trust the Shield® are trademarks of Ashcroft Inc. For more information, see Ashcroft Brands & Trademarks DIMENSIONS 1.45 Ø0.16 "B2" 1/4 BARB FITTINGS POWER HI LO SPANZERO 1.89 3.332.90 1.32Ø0.20 0.36 POWER HI LO SPANZERO 1.45 1.89 0.56 3.33 2.90 1.32 0.35 POWER HI LO SPANZERO 4.85 ASSEMBLED WITH 101A213-01 CONDUIT KIT Ø0.88 2.06 0.78 “MB2” ¼ BARBED FITTINGS “F01” 1⁄8 NPT FEMALE FITTINGS ASSEMBLED WITH 101A213-01 ½˝ PLENUM/CONDUIT KIT For reference only, consult Ashcroft for specific dimensional drawings. All dimensions are identified in inches.