Features

  • SIP SSR
  • Ratings of 5 A @ 660 VAC
  • SCR output for heavy industrial loads
  • AC or DC control
  • Zero-crossing (resistive loads) or random-fire (inductive loads) output
  • CE Compliant to EN60950-1 Control Voltage 5 A 5 A 5 A 3-15 VDC CX240D5 4-15 VDC CX380D5 CX480D5 15-32 VDC CXE240D5 CXE380D5 CXE480D5 18-36 VAC CXE240A5 90-140 VAC CX240A5 PRODUCT SELECTION

www.sensata.comCopyright © 2021 Sensata Technologies, Inc. Input (1) General (1) Description Parameters Dielectric Strength, Input/Output (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC)

109 Ohm

Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -10°C to 80°C Ambient Storage Temperature Range -10°C to 125°C Weight (typical) 0.4 oz (11g) Encapsulation Thermally Conductive Epoxy Enclosure and PCB Meets the requirements of IEC60335-1 SPECIFICATIONS Output (1) Description CX240x5 CX380x5 CX480x5 Operating Voltage (47-63Hz) [Vrms] 12-280 48-530 48-660 Transient Overvoltage [Vpk] 600 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] 2 500 500 500 Maximum Load Current [Arms] 5 5 5 Minimum Load Current [Arms] 0.06 0.06 0.06 Maximum Surge Current (16.6msec) [Apk] 250 250 250 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.4 1.4 1.4 Maximum I² t for Fusing (8.3msec) [A² sec] 260 260 260 Minimum Power Factor (at Maximum load) 0.5 0.5 0.5 HP rating UL 508/IEC60947[HP/KW]: 380VAC NA 0.33/0.25 0.33/0.25 HP rating UL 508/IEC60947[HP/KW]: 480VAC NA NA 0.5/0.37 Description CX240Dx CX380/480Dx CXExxxDx CX240A5 CXE240A5 Nominal Voltage 5 VDC 5 VDC 24 VDC 120 VAC 24 VAC Control Voltage Range 3-15 VDC 4-15 VDC 15-32 VDC 90-140 VAC 18-36 VAC Typical Input Current 15 mAdc 15 mAdc 15 mAdc 10mArms 10mArms Nominal Input Impedence 300 Ohm 240 Ohm 1500 Ohm 14.1K Ohm 2.1K Ohm Maximum Turn-On Time [msec] 3 1/2 Cycle 1/2 Cycle 1/2 Cycle 10 10 Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle 40 40

www.sensata.comCopyright © 2021 Sensata Technologies, Inc. THERMAL DERATE INFORMATION MECHANICAL SPECIFICATIONS WIRING DIAGRAMS LOAD TRIGGER CIRCUIT B A AC -DC +DC Load can be wired in location A or B AC 2 1LOAD LOAD TRIGGER CIRCUIT 4 V LOAD B A AC AC AC AC 2 1 AC/DC Converter Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Ambient Temperature (ºC) Load Current (Amps) 6.0 5.0 4.0 3.0 2.0 20 40 60 80 1.0

www.sensata.comCopyright © 2021 Sensata Technologies, Inc. Series CX Control Voltage Blank: 3-15 VDC (240 and D suffix only) 4-15 VDC (380/480 and D suffix only) 90-140 VAC (A suffix only) E: 15-32 VDC (D suffix only) 18-36 VAC (A suffix only) Operating Voltage 240: 12-280 VAC 380: 48-530 VAC 480: 48-660 VAC Control Input Type D: DC Input A: AC Input Operating Rating 5: 5 Amps Switching Mode Blank: Zero Voltage Turn-On R: Random Turn-on ORDERING OPTIONS Example : CXE240D5R Required for valid part number For options only and not required for valid part number AGENCY APPROVALS & CERTIFICATIONS CX - E - 240 - D - 5 - R Designed in accordance with the requirements of IEC 62314 IEC60335-1: Resistance to heat and fire meets the requirements of section 30, evaluated by TUV SUD. Glow Wire Test, per requirements of IEC/EN 60695-2-10 and IEC/EN 60695-2-11 Ball Pressure Test, per requirements of IEC/EN 60695-10-2 E116949 LR 81689 GENERAL NOTES (1) All parameters at 25°C unless otherwise specified (2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (3) Turn-On time for random turn-on versions is 0.01 msec (DC control Models) (DC Control only)

+1 (877) 502 5500 – Option 2 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Rev. 04/01/21 ECN 21039 FDE-07-01 Rev. B www.sensata.com CONTACT USCopyright © 2021 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.