Description

  • Surface mount magnetics that can be used as single or coupled inductors or 1:1 transformers that provide isolation between two windings
  • OCTA-PAC’s are designed around high frequency, low loss material
  • ECONO-PAC’s are a lower cost version of OCTA-PAC’s offering high saturation flux density
  • OCTA-PAC PLUS’s offer higher current ratings and higher saturation flux densities than OCTA-PAC and ECONO-PAC
  • Secure 4 Terminal Mounting
  • Inductor more versatile inductance combination by series or parallel connections

Applications

  • Computer and portable power devices
  • LCD panels, DVD players
  • Inductor: DC-DC converters
  • Buck, boost, forward, and resonant converters
  • Noise filtering and filter chokes
  • Transformers: 1:1 300Vdc isolation, flyback, sepic Environmental Data
  • Storage temperature range: -40°C to +125°C
  • Operating ambient temperature range: -40°C to +85°C (range is application specific).
  • Infrared reflow temperature: +240°C for 30 seconds maximum Packaging
  • Supplied in tape and reel packaging, 1100 (EP01, OPA1, and OP01), 800 (EP02, OP02, OPA2, EP03, OPA3, and OP03), and 600 (EP04, OPA4, and OP04) per reel Legend
  • No suffix is OCTA-PAC
  • P suffix is ECONO-PAC™
  • A suffix is OCTA-PAC® PLUS ECONO-PAC™/OCTA-PAC ® OCTA-PAC ® PLUS Power Inductors and Transformers Open Circuit Full Load Full Load DC Open Circuit Full Load Full Load DC Part Inductance Inductance Current Resistance Inductance Inductance Current Resistance Number µH +/-20% µH min. Adc ohms max. µH +/-20% µH min. Adc ohms max. PARALLEL SERIES

Open Circuit Full Load Full Load DC Open Circuit Full Load Full Load DC Part Inductance Inductance Current Resistance Inductance Inductance Current Resistance Number µH +/-20% µH min. Adc ohms max. µH +/-20% µH min. Adc ohms max. PARALLEL SERIES ECONO-PAC™/OCTA-PAC ® OCTA-PAC ® PLUS Power Inductors and Transformers

Open Circuit Full Load Full Load DC Open Circuit Full Load Full Load DC Part Inductance Inductance Current Resistance Inductance Inductance Current Resistance Number µH +/-20% µH min. Adc ohms max. µH +/-20% µH min. Adc ohms max. PARALLEL SERIES ECONO-PAC™/OCTA-PAC ® OCTA-PAC ® PLUS Power Inductors and Transformers

ECONO-PAC™/OCTA-PAC ® OCTA-PAC ® PLUS Power Inductors and Transformers Parallel Ratings Series Ratings Part Number Rated OCL (1) I sat. (2) I rms. (3) DCR Ω (4) Volt (7) OCL (1) I sat. (2) I r ms. (3) DCR Ω (4) Volt (7) Inductance nominal Amperes Amperes typ. µ-Sec nominal Amperes Amperes typ. µ-Sec (µH) +/-25% Peak @ 20°C. +/-25% Peak @ 20°C. (µH) (µH) 1) Open Circuit Inductance Test Parameters: 100kHz, 0.250 Vrms, 0.0 Adc Parallel: (1,4 - 3,2) Series: (1 - 3) tie (2 - 4) 2) Peak current for approximately 30% roll-off 3) RMS current, delta temp. of 40° C ambient temperature of 85° C 4) Values @ 20° C, Maximum DCR is +15% of typical value. 5) Hipot rating: winding to winding: 300Vdc min. 6) Turns Ratio: (1-2):(4-3) 1:1 7) Applied volt-time product (v-us) across the inductor. This value represents the applied V-us at 300KHz necessary to generate a core loss equal to 10% of the total losses for a 40°C temperature rise.

ECONO-PAC™/OCTA-PAC ® OCTA-PAC ® PLUS Power Inductors and Transformers Parallel Ratings Series Ratings Part Number Rated OCL (1) I sat. (2) I r ms. (3) DCR Ω (4) Volt (7) OCL (1) I sat. (2) I r ms. (3) DCR Ω (4) Volt (7) Inductance nominal Amperes Amperes typ. µ -Sec nominal Amperes Amperes typ. µ-Sec (µH) +/-25% Peak @ 20°C. +/-25% Peak @ 20°C. (µH) (µH) 1) Open Circuit Inductance Test Parameters: 100kHz, 0.250 Vrms, 0.0 Adc Parallel: (1,4 - 3,2) Series: (1 - 3) tie (2 - 4) 2) Peak current for approximately 30% roll-off 3) RMS current, delta temp. of 40° C without core loss, ambient temperature of 85°C. It is recommended that the temperature of the part not exceed 125°C 4) Values @ 20° C, Maximum DCR is +15% of typical value. 5) Hipot rating: winding to winding: 300Vdc min. 6) Turns Ratio: (1-2):(4-3) 1:1 7) Applied volt-time product (v-us) across the inductor. This value represents the applied V-us at 300KHz necessary to generate a core loss equal to 10% of the total losses for a 40°C temperature rise.

ECONO-PAC™/OCTA-PAC ® OCTA-PAC ® PLUS Power Inductors and Transformers Mechanical Diagrams CTX 1, 1P , 1A Series CTX 2, 2P , 2A Series CTX 3, 3P , 3A Series CTX 4, 4P , 4A Series Dimensions in Millimeters. wwllyy = (date code) R = revision level

ECONO-PAC™/OCTA-PAC ® OCTA-PAC ® PLUS Power Inductors and Transformers CTX 2, 2P , 2A Series CTX 3, 3P , 3A Series CTX 4, 4P , 4A Series Packaging Information CTX 1, 1P , 1A Series Dimensions are in millimeters. Direction of Feed➞ Direction of Feed➞ Direction of Feed➞ Direction of Feed➞ Parts packaged on 13" Diameter reel, 1,100 parts per reel. Parts packaged on 13" Diameter reel, 800 parts per reel. Parts packaged on 13" Diameter reel, 800 parts per reel. Parts packaged on 13" Diameter reel, 600 parts per reel.

Visit us on the Web at www.cooperET.com

3601 Quantum Boulevard Boynton Beach, Florida 33426-8638

Tel: +1-561-752-5000 Toll Free: +1-888-414-2645 Fax: +1-561-742-1178 This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Electronic Technologies reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Electronic Technologies also reserves the right to change or update, without notice, any technical informa tion contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. PM-4314 1/04 © Cooper Electronic Technologies 2004

  • INDUCTANCE VS. CURRENT : Inductance will fall off as DC Current is increased. (See Inductance vs. Current graph).
  • INDUCTANCE VS. FREQUENCY: Inductance roll-off versus Frequency approximates 3% at 1 megaHertz.
  • FREQUENCY RESPONSE: Wide-band frequency response to 1 megaHertz.
  • CURRENT LIMITATION: The maximum allowable currents are defined by the internal “hot-spot” temperatures which are limited to 130°C, including ambient. -35 -15 +5 +25 +45 +65 +85 +105 +125 INDUCTANCE VS. TEMPERATUREPercentage Change in Inductance Temperature in Degrees C. -10 -12 -14 ECONO-PAC OCTA-PAC INDUCTANCE VS. CURRENTPercentage of Inductance Per Unit Full Load Current 100 ECONO-PAC OCTA-PAC TEMPERATURE RISE VS. RATED CURRENT Max. Ambient plus Rise = 125°C Degrees C Per Unit Full Load Current 140 120 100 ECONO-PAC & OCTA-PAC Performance Characteristics ECONO-PAC™/OCTA-PAC ® OCTA-PAC ® PLUS Power Inductors and Transformers OCTA-PAC ® PLUS Typical Inductance vs. DC Current OCTA-PAC ® PLUS Winding Loss Derating with Core Loss 02 0 4 06 08 0 100 120 140 160 180 200 100 % of Isat % of OCL 100080060050040030020010080605040302010 % of Applied Volt-µ-Second Rating % of Losses from Irms (maximum) 1MHz 0KHz 300KHz 200KHz 100KHz